3M ESPE

3M Dental Mixing Units

3M Pentamix Lite Operating Instructions Sept 2019

Operating Instructions

90 Pages

Seite 5 - 210 x 297 mm - 3100016478/01 - SCHWARZ - 19-187 (kn)  ENGLISH  en   1. Safety Instructions  en ENGLISH   Pentamix Lite  ATTENTION! Read these Operating Instructions carefully before plugging in and operating the unit! As with all technical units, the trouble-free function and safe operation of this unit can be assured only if standard safety procedures and the special safety instructions in these Operating Instructions are observed.  Automatic Mixing Unit Operating Instructions  3M Deutschland GmbH guarantees trouble-free operation of the Pentamix system only if 3M system components are used exclusively.  ™  1. The unit may be used only in strict accordance with the following instructions. We accept no liability for any damage arising from any other or improper use of this unit. 2. If the unit is moved from a cold into a warm environment, condensation can result in a hazardous situation. Never begin operating the unit until it has reached the ambient temperature. 3. The power plug must be connected to a suitably grounded socket before the unit is operated. If an extension cable is used, make sure that it also provides a ground wire. 4. Position the unit so that the power plug is accessible at all times. 5. The unit must be placed on a non-slip, level surface to insure stable placement. 6. Always turn off the unit and disconnect the plug from the power source before changing the plunger discs. 7. When changing the plunger discs, position the smooth side of the new discs towards the foil bag (the opposite side of the discs with the fan-shaped depressions must face away). Otherwise, the foil bag might be damaged.  Table of Contents  8. To avoid electrical shock, do not insert any objects into the unit. Page  1. Safety Instructions  5  2. Product Description  5  3. Technical Data  6  4. Installation  6  5. Operation 6 5.1 Swiveling the Unit into Working Position 6 5.2 Loading the Cartridge 6 5.3 Inserting the Cartridge 6 5.4 Attaching the Mixing Tip 6 5.5 Starting a New Cartridge 6 5.6 Loading the Impression Tray and Penta Elastomer Syringe 6 5.7 Removing the Cartridge 7 5.8 Re-starting a Partly Empty Cartridge 7 5.9 Replacing a Cartridge 7 5.10 Storage of Partially Used Cartridges 7 5.11 Fill Level Gauge 7 5.12 Parking the Unit 7 5.13 Transporting the Unit 7 5.14 Disposal of Consumable Materials 7 5.15 Return of Old Electric and Electronic Equipment for Disposal 7 5.16 Notes 7 6. Malfunctions and Error Messages  8  7. Maintenance and Care 7.1 Replacement of the Plunger Discs 7.2 Care 7.3 Maintenance and Repair  8 8 8 8  8. Customer Information 8.1 Warranty 8.2 Limitation of Liability  8 8 8  Symbol Glossary  9  9. Use only genuine 3M parts when replacing defective components as directed in these Operating Instructions. We assume no liability for any damage caused by the use of non-3M parts. 10. If, for any reason, it is possible that the safety of a unit has been compromised, that unit must be removed from operation and identified in such a way that it is not inadvertently operated again by a third party. Safety may have been compromised, for example, if the unit does not work as specified or is visibly damaged. 11. Keep solvents, flammable liquids, and powerful heat sources away from the unit as they may damage the plastic housing. 12. Do not allow any cleaning agents to enter the unit during cleaning as they could cause an electrical short or a dangerous malfunction. 13. Only a properly trained, authorized technician may open the unit housing and repair the unit. Please report a serious incident occurring in relation to the device to 3M and the local competent authority (EU) or local regulatory authority.  2. Product Description Pentamix™ Lite is an automatic mixing unit for the preparation of Penta™ impression materials. 3M Penta impression materials have been specifically designed for this unit and are supplied in special foil bags. This is the only form of packaging which can be used in the Pentamix Lite units. Every Penta™ foil bag is sealed with a PentaMatic sealing cap. The external geometry of the sealing cap insures its proper positioning on the cartridge. When the Pentamix unit is turned on, a special internal device opens the foil bag automatically once sufficient pressure has been built up by the plunger. The connection pieces located on the PentaMatic sealing caps serve for proper attachment of the mixing tip. The cartridges and the PentaMatic sealing caps act together as a stable unit for the preparation of pastes in the Pentamix unit and allow a change of products without intermediate cleaning of the device and  5
File Type: PDF
File Size: 23.5 MB
File Name: 3M ESPE - 310001647801 - 3M Pentamix Lite Operating Instructions Sept 2019 - 2019-09.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions