3M ESPE

Elipar DeepCure-S Curing Light Operating Instructions

Operating Instructions

130 Pages

Elipar™ DeepCure-S LED Curing Light Table of Contents Page Safety 1 Glossary of Symbols 2 Product Description 2 Fields of Application 3 Technical Data 3 Charger 3 Handpiece 3 Charger and Handpiece 4 Transport and Storage Conditions 4 Installation of the Unit 4 Factory Settings 4 Initial Steps 4 Charger 4 Light Guide/Handpiece 4 Inserting the Battery 4 Battery Charging 5 Operating Status Display of the Charger 5 Power Level Display of the Handpiece 5 Operation 5 Selection of Exposure Time 5 Activating and Deactivating the Light 6 Positioning the Light Guide 6 Removing and Inserting the Light Guide from/into the Handpiece 6 Measurement of Light Intensity 6 Sleep Mode 6 7 Acoustical Signals - Handpiece Troubleshooting 7 Maintenance and Care 8 Inserting/Removing the Battery 8 Handpiece/Battery Care 8 Cleaning the Light Guide 8 Clean Charger, Handpiece, and Glare Shield 9 Storage of the Handpiece during Extended Periods of Non-Use 9 Return of Old Electric and Electronic Equipment for Disposal 10 Collection 10 Return and Collection Systems 10 Meaning of the Symbols 10 Customer Information 10 Warranty 10 Limitation of Liability 10  Safety PLEASE NOTE! Prior to installation and start-up of the unit, please read these instructions carefully! As with all technical devices, the proper function and safe operation of this unit depend on the user’s compliance with the standard safety procedures as well as the specific safety recommendations presented in these Operating Instructions. 1. Use of the device is restricted to trained personnel in accordance with the instructions below. The manufacturer assumes no liability for any damage resulting from the use of this unit for any other purpose. 2. Prior to start-up of the unit make sure that the operating voltage stated on the rating plate is compatible with the available mains voltage. Operation of the unit at a different voltage may damage the unit. 3. Position the unit so that the power plug is accessible at all times. The power plug is used to turn the charger on and off. To disconnect the charger from the mains, remove the power plug from the electrical outlet. 4. Use only the 3M ESPE charger which is provided with the unit. The use of any other charger can result in damage to the battery. 5. CAUTION. Do not stare at source. May be harmful to the eyes. Restrict exposure to the area of the oral cavity in which clinical treatment is intended. Protect patient and user from reflection and intensive scattered light by taking the appropriate precautions, e.g., glare shields, goggles, or coverings. 6. CAUTION! As is the case for all high-intensity lightcuring devices, the high light intensity is accompanied by heat generation on the exposed surface. This heat can result in irreversible damage if there is longer exposure in the proximity of the pulp or soft tissue. The exposure times given in the manufacturer’s instructions must be observed exactly to avoid any such damage. Uninterrupted exposure times of the same tooth surface in excess of 20 seconds and direct contact with oral mucosa or skin must be strictly avoided. Scientists working in this field are in agreement that the irritation caused by heat generated during light curing can be minimized by taking two simple precautions: • Polymerization with external cooling from an air flow • Polymerization at intermittent intervals (e.g., 2 exposures lasting 10 seconds each instead of 1 exposure lasting 20 seconds). 7. Elipar DeepCure-S may be operated only with the supplied light guide or original 3M ESPE Elipar DeepCure-S replacement light guide. The light guide 1  en ENGLISH   en ENGLISH 
File Type: PDF
File Size: 4.02 MB
File Name: 3M ESPE - 44000769354-02 - Elipar DeepCure-S Curing Light Operating Instructions.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions