3M ESPE
Elipar S10 LED Usage Tips Operating Instructions
Operating Instructions
4 Pages
Preview
Page 1
USAGE TIPS EliparTM S10 LED Curing Light
1
2
Inserting the Battery: r3FNPWFUIFQSPUFDUJWFDBQGSPN UIFUISFBEFEFOEPGUIFCBUUFSZ r4MPXMZJOTFSUUIFSFDIBSHFBCMF CBUUFSZJOUPUIFIBOEQJFDFXJUI UIFUISFBEFETJEFPGUIFCBUUFSZ UPXBSETUIFNFUBMIPVTJOH*OTFSU UIFCBUUFSZVOUJMJUDBOOPUCFTMJE BOZGVSUIFS3PUBUFUIFCBUUFSZ DMPDLXJTFVOUJMUIFTFBMJTQSFTTFE àSNMZBHBJOTUUIFNFUBMIPVTJOH 'JHVSFTBOE
Removing the Battery: r3PUBUFUIFCPUUPNTFDUJPOPGUIF IBOEQJFDFDPVOUFSDMPDLXJTFVOUJM UIFCBUUFSZDBOCFSFNPWFE1VMM UIFCBUUFSZPVUPGUIFIBOEQJFDF 'JHVSF
3
1 of 4
USAGE TIPS EliparTM S10 LED Curing Light Charging Steps: r 1MBDF UIF DIBSHFS CBTF PO B MFWFM TVSGBDF r 1MVH UIF DIBSHFS CBTF JOUP B QPXFS TVQQMZ 5IFHSFFOTUBUVT-&%MJHIUPOUIFSJHIUTJEF PG UIF EFWJDF TIPVME JMMVNJOBUF JOEJDBUJOH UIBUUIFVOJUJTSFBEZGPSPQFSBUJPO 'JHVSF
4
r 1SJPS UP àSTU VTF PS XIFO SFDIBSHJOH QMBDF UIF CBUUFSZ PS IBOEQJFDF XJUI CBUUFSZ JOUP UIFDIBSHFSCBTFUPDIBSHFUIFCBUUFSZ r 5IF HSFFO TUBUVT -&% MJHIU XJMM áBTI BT UIFCBUUFSZJTDIBSHJOH8IFOUIFTUBUVT -&%MJHIUJTTUFBEZHSFFO UIFDIBSHJOH JTDPNQMFUF 'JHVSF 5
6
Cleaning/Disinfecting the Charger Base, Handpiece, and Glare Shield: r8JQFUIFIBOEQJFDF DIBSHFSCBTF BOE HMBSFTIJFMEGPSEJTJOGFDUJPO%POPUTQSBZ %JTJOGFDUJOHBHFOUTNVTUOPUFOUFSUIFVOJU 'JHVSF r "QQMZEJTJOGFDUJOHBHFOUXJUIBTPGUMJOUGSFF DMPUIBOEBMMPXEJTJOGFDUBOUUPSFNBJOPO TVSGBDF GPS UIF BNPVOU PG UJNF SFDPNNFOEFE CZUIFNBOVGBDUVSFS'PMMPXQSFDBVUJPOTGPSVTF r 1FSGPSN B àOBM XJQF XJUI B OFX DMFBO DMPUI UP SFNPWF BOZ SFTJEVBM EFQPTJUT PG UIF EJTJOGFDUBOUTPMVUJPO r %P OPU VTF TPMWFOUT PS BCSBTJWF DMFBOJOH BHFOUTBTUIFTFNBZEBNBHFQMBTUJDQBSUT
2 of 4
USAGE TIPS EliparTM S10 LED Curing Light
7
r ,FFQ UIF DIBSHF DPOUBDU QJOT ESZ 8FUDIBSHFDPOUBDUQJOTXJMMCF TJHOBMFECZBSFETUBUVT-&%MJHIU *GUIJTPDDVST TJNQMZSFNPWFUIF CBUUFSZ PS IBOEQJFDF XJUI CBUUFSZ GSPN UIF DIBSHJOH CBTF BOE UIPSPVHIMZ ESZUIFDPOUBDUTPOUIFDIBSHJOHCBTF BOECPUUPNTFDUJPOPGCBUUFSZVTJOH B ESZ DMPUI 'JHVSF Monitoring Light Intensity: r3PVUJOFMZNPOJUPSUIFMJHIUJOUFOTJUZ BTEFTDSJCFEJOUIF*OTUSVDUJPOTGPS 6TF *G UIF JOUFOTJUZ JT OPU PQFSBUJOH XJUIJO UIF TUBUFE QBSBNFUFST DMFBO UIFMJHIUHVJEFBOEIBOEQJFDFPQUJDT BTJOTUSVDUFECFMPX 'JHVSF
8
3 of 4
USAGE TIPS EliparTM S10 LED Curing Light
9
10
Cleaning the Light Guide and Handpiece Optics: r5IF UJQ PG UIF MJHIU HVJEF TIPVME CF SFHVMBSMZXJQFEDMFBOXJUIBTPGUDMPUI r $VSFE DPNQPTJUF PO UIF UJQ PG UIF MJHIU HVJEFTIPVMECFSFNPWFEXJUIBMDPIPM "QMBTUJDTQBUVMBNBZIFMQJOSFNPWJOH NBUFSJBM %P OPU VTF BOZ TIBSQ PS QPJOUFEJOTUSVNFOUT r 5P DMFBO UIF IBOEQJFDF PQUJDT SFNPWF NBHOFUJDMJHIUHVJEFGSPNIBOEQJFDF r5IFQSPUFDUJOHHMBTTPGUIFIBOEQJFDF PQUJDT DBO CF DMFBOFE XJUI B TPGU MJOUGSFFDMPUI 'JHVSF Sterilizing the Light Guide: r5IFMJHIUHVJEFDBOCFBVUPDMBWFE0OMZ TUFBNTUFSJMJ[BUJPOTIPVMECFVTFEBT BTUFSJMJ[BUJPOQSPDFEVSF3FGFSUPUIF &MJQBS4-&%$VSJOH-JHIU0QFSBUJOH *OTUSVDUJPOT GPS SFDPNNFOEFE TUFSJMJ[BUJPO DZDMFT%POPUTUFSJMJ[FUIFMJHIUHVJEF XJUIDIFNJDBMTPSIPUBJS 'JHVSF r1SJPSUPTUFSJMJ[BUJPO SFNPWFBOZDVSFE DPNQPTJUFPOUIFUJQPGUIFMJHIUHVJEF BTEFTDSJCFEBCPWF r8BUFSTQPUTTIPVMECFXJQFEPGGCPUI FOETPGUIFMJHIUHVJEFCFGPSFBOEBGUFS TUFBNTUFSJMJ[BUJPO
3M ESPE $ENTALå0RODUCTS å3Tå0AUL å-.å å53!åsåWWW-%30%COM 3M ESPE Customer Care/MSDS Information: U.S.A. 1-800-634-2249 and Canada 1-888-363-3685 - å%30%åANDå%LIPARåAREåTRADEMARKSåOFå-åORå-å%30%å!' ¥å-ååå!LLåRIGHTSåRESERVED å
4 of 4