Users Manual
26 Pages
Preview
Page 1
Abbott Diabetes Care 666 Doncaster Road Doncaster 3108 Victoria, Australia ABN 95000 180 389 1800-801-478 Abbott Laboratories (M) Sdn Bhd Abbott Diabetes Care No.22,Jalan Pemaju U1/15, HICOM-Glenmarie Ind.Park 40150 Shah Alam, Selangor Malaysia 03-5569-1919
Abbott Laboratories (N. Z.) Ltd, Ground Floor Bldg. D, 4 Pacific Rise, Mount Wellington, P.O. Box 22-801 Otahuhu, Auckland, New Zealand 0800 106 100
National Phytopharma Joint-Stock Company 24 Nguyen Thi Nghia, District 1 Ho Chi Minh City Vietnam 08-910-6640 ext 849
Abbott Laboratories Pakistan Ltd. Abbott Diabetes Care Opposite Radio Pakistan Transmission, Hyderabad Road, Landhi Karachi, Pakistan 021-35100321
Abbott Laboratories Abbott Diabetes Care 102 E.De Los Santos Ave. Madison Street 1554 Mandaluyong, Metro Manila Philippines 02-7028577 02-7028578
Abbott Laboratories (Singapore) Pte Ltd Abbott Diabetes Care 1 Maritime Square #12-09 Harbour Front Centre Singapore 099253 1800-272-2881
User’s Manual
Blood Glucose Monitoring System
FreeStyle and other brand marks are trademarks of Abbott Diabetes Care Inc. in various jurisdictions. ©2010 Abbott ART20287 Rev. A 11/10
ART20287_Rev-A-Cvr.indd 1-2
11/17/10 2:40 PM
DO NOT PRINT FROM THIS FILE FOR REFERENCE ONLY
Definition of Symbols These symbols are associated with your meter. Batch code
Catalogue number
The European Battery Directive requires separate collection of spent batteries, aiming to facilitate recycling and to protect the environment. The batteries in this product should be removed and disposed in accordance with local regulations for separate collection of spent batteries.
Caution
This packaging is capable of being recycled
Consult instructions for use
Manufacturer
Date of manufacture
Sterilised using irradiation (lancets only)
Do not drink
Temperature limitation
Do not reuse
Use by
In vitro diagnostic medical device
Serial number
ART20287_Rev-A-Man.indd 1
DO NOT PRINT FROM THIS FILE FOR REFERENCE ONLY
11/17/10 3:01 PM
Table of Contents
Intended Use... 1
Language
Monitoring System Kit Contents... 3
Language
Setting Up the Meter... 4 Enter Setup Mode...4 Beeper...4 Time...5 Date...5 Time Format... 5 Date Format... 6 Measurement Units... 6
Language
Testing Your Blood Glucose... 7 Important Testing Notes...7 Test Site ... 8 Alternative Sites ... 9 Performing a Blood Glucose Test... 10
Language
Understanding Blood Glucose Test Results... 13 Low and High Blood Glucose Results ... 13
MediSense or Optium Glucose and Ketone Control Solutions... 23 Important Control Solution Testing Notes... 24 Performing a Control Solution Test... 25 Managing Your Results... 29 Viewing Test Results in Memory ... 29 Viewing Blood Glucose Averages... 31 Transferring Results to a Computer... 33 Error Messages... 33 E-1 to E-9, What It Means, What To Do... 33 Troubleshooting... 36 Maintaining the Meter... 39 Replacing the Battery... 39 Cleaning the Meter ... 41 Storing the Meter... 42 Specifications... 42 References... 45
Testing Your Blood β-Ketone... 16 Important Testing Notes... 16 Test Site ... 17 Performing a Blood β-Ketone Test ... 17 Understanding Blood β-Ketone Test Results... 21 High Blood β-Ketone Results... 21
ART20287_Rev-A-Man.indd 2-3
11/17/10 3:01 PM
Language Language ART20287_Rev-A-Man.indd 1-2
Observe caution when using around children. Small parts may constitute a choking hazard.
How Your FreeStyle Optium Blood Glucose Monitoring System Works When you insert a test strip into your meter, the Apply Sample message shows on your meter’s display window. When a blood sample or control solution sample is applied to the test strip, the glucose or β-Ketone reacts with the chemicals on the test strip. This reaction produces a small electrical current that is measured. The result shows on your meter’s display window. IMPORTANT: Avoid getting dust, dirt, blood, control solution, water or any other substance in the meter’s test strip port.
Language
Read the instructions in this user’s manual. Failure to follow instructions will cause incorrect results. Practise the testing procedures before using the meter. Follow your healthcare professional’s advice when testing blood glucose levels and blood β-Ketone levels.
Language
Language
1
IMPORTANT: Use only FreeStyle Optium blood glucose test strips and FreeStyle Optium blood β-Ketone test strips. Other test strips may produce inaccurate results.
Potential infection risk: Healthcare professionals performing blood tests with this system on multiple patients must always wear gloves and should follow the infection control policies and procedures approved by their facility.
Language
Language
Use outside the body only (in vitro diagnostic use) for self testing or professional use in the management of diabetes. Use for measuring blood glucose from samples taken from the forearm, upper arm, base of the thumb, or fingers. • Test blood glucose in fresh whole blood samples • Test blood β-Ketone (β-hydroxybutyrate) in fresh whole blood samples from fingers only
IMPORTANT: See test strip instructions for use for more information about sample types.
Language
Intended Use
2 11/17/10 3:01 PM
Monitoring System Kit contains:
Enter Setup Mode
• Logbook • Warranty Card
Commands • Press to move between setup displays • Press to move forward • Press to go back • Press to turn display light On and Off
• Blood Glucose Test Strips • Lancing Device
• Lancets
Press and hold
Language
and
until
and
appear. This indicates the beeper is turned on.
indicate the beeper is turned off.
Items not included:
• Blood β-Ketone Test Strips • Control Solutions
Language
3 ART20287_Rev-A-Man.indd 3-4
• Data Management System
Beeper Press or to change the beeper setting. Press to save the beeper setting and move to set time.
The beeper sounds when: • The test countdown starts • The test countdown ends
Language
Language
Your Kit may also contain:
Language
Language
• Meter • User’s Manual • Carrying Case
Start with the meter off (no test strip inserted).
Language
Setting Up the Meter
Language
Monitoring System Kit Contents
4 11/17/10 3:01 PM
Time
Date Format
Language
Measurement Units
Language
The unit of measurement set by the factory appears. You cannot change this setting. Contact Customer Service for more information. Press to return to set beeper, or press and hold to turn off the meter.
Time Format 24 Hour Format
5 ART20287_Rev-A-Man.indd 5-6
Language
IMPORTANT: Please check that the correct time and date is set before you use the meter for the first time. This will help you keep records of when you monitor and will help you and your healthcare professional make informed decisions about your care. You must set the time and date to review averages.
Note: If using the 12-hour time format, AM and PM appear. The time format flashes. Press or to change the time format. Press save the time format and to move to set date format.
to
Language
The year flashes. Press or until the correct year appears. Press to save the year and to move to set month. The month flashes. Press or until the correct month appears. Press to save the month and to move to set day. The day flashes. Press or until the correct day appears. Press to save the day and to move to set time format.
Language
Language
Month – Day
to
Day.Month
Date Year
Month – Day
The date format flashes. Press or to change the date format. Press save the date format and to move to the measurement units.
Language
Language
The hour flashes. Press or until the correct hour appears. Press to save the hour and to move to set minutes. The minutes flash. Press or until the correct minutes appear. Press to save the minutes and to move to set date.
6 11/17/10 3:01 PM
Important Testing Notes Language
E.g. Expiry date: March 31, 2012
This display always appears when the meter is turned on. You should check that your meter matches the example you see here exactly every time your meter turns on.
Note: See test strip instructions for use for operating range and more information on limitations of use.
Language
Do not use the meter if the display check screen does not exactly match the example. If the screen does not match, the meter may show an incorrect result. Please contact Customer Service.
Test Site
Language Language
D5
45001
A138
2012/03
E.g. Expiry date: March 31, 2012
7 ART20287_Rev-A-Man.indd 7-8
• Use the meter within the test strip operating range • Use the test strip immediately after removing it from its foil packet • Use each test strip only once
Do not use expired test strips; they may produce inaccurate results. The expiry date is the last day of the month if only the month and year are shown. Do not use a wet, bent, scratched or damaged test strip. Do not use the test strip if its foil packet has a puncture or tear in it.
Fingertips
IMPORTANT: Wash your hands and the test site with warm soapy water to ensure accurate results. Thoroughly dry your hands and the test site. To warm the site, apply a warm dry pad or rub vigorously for a few seconds. Note: Avoid areas near bones, areas with lots of hair, and squeezing the puncture site. Bruising may occur at alternate sites, but will disappear quickly. If bruising occurs, consider selecting another site. Finger tip testing is different to alternative site testing. (Adjust the lancing device accordingly for testing site. See lancing device instructions for use for more information.)
Language
A138
2012/03
Language
45001
Language
D5
Language
Testing Your Blood Glucose
8 11/17/10 3:01 PM
Alternative Sites
Language
2
Forearm
Language
9 ART20287_Rev-A-Man.indd 9-10
This display always appears when the meter is turned on. Do not use the meter if the display check screen does not exactly match the example. Contact Customer Service. See “Testing Your Blood Glucose” section for more information.
Time and date (if set) appear next.
Language Language
4˚C
Language
Upper arm
Do not use blood samples from alternative sites when: • You think your blood glucose is low or changing rapidly • You have been diagnosed with hypoglycaemic unawareness • Alternative site results do not match the way you feel • You are within two hours of eating a meal, taking insulin, or exercising
Insert the Test Strip With the contact bars (3 black lines) facing up, insert the test strip into the meter until it stops. This turns on the meter. Note: The meter turns off after 3 minutes of inactivity. Remove and reinsert the unused test strip to restart the meter.
Language
Language
levels change rapidly (e.g. after eating a meal or taking insulin, or during or after exercise) • Use alternative sites before, or more than two hours after, you eat a meal, take insulin, or exercise
Open the foil test strip packet at the notch and tear down to remove the test strip.
Blood Glucose Sensor Electrode Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
• Alternative site results may differ from fingertip results when blood glucose
Base of thumb
2
Language
Obtaining a blood sample from alternative sites – forearm, upper arm, and base of the thumb – is subject to limitation. Contact your healthcare professional before beginning alternative site testing.
2
Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
Performing a Blood Glucose Test
10 11/17/10 3:01 PM
Language
Apply Blood to the Test Strip Bring the blood drop to the white area at the end of the test strip. The blood is drawn into the test strip.
Language
11 ART20287_Rev-A-Man.indd 11-12
IMPORTANT: If the countdown does not start, you may not have applied enough blood to the test strip. See test strip instructions for use for re-application instructions. If the countdown still does not start, remove the used strip and discard it correctly. Start a new test with a new test strip.
View the Result The meter beeps (if sound is on) when the result appears on the display. The test is complete (example shown). The result is stored in memory or you can write it in a logbook. Turn Off the Meter Use the opened foil packet to remove the used test strip. This turns off the meter. Discard the used test strip correctly. Note: You can also press and hold for at least 2 seconds to turn off the meter. The meter also turns off after 60 seconds of inactivity.
Language Language
2
Language
The countdown appears on the display as the meter checks your glucose level. Note: Do not remove the test strip from the meter or disturb the test strip during the countdown.
Language
Language
Obtain a Blood Sample Select a test site. Use the lancing device to obtain a blood sample. (See lancing device instructions for use for more information.)
Hold the blood drop to the white area until the meter beeps (if sound is on) and the status bar appears on the display. This indicates the test strip has obtained enough blood.
Language
The Apply Sample symbols and appear next, indicating the meter is ready for you to apply a sample to the test strip.
12 11/17/10 3:01 PM
Understanding Blood Glucose Test Results
Meter:
Language
Appears when result is: Lower than 1.1 mmol/L (Lower than 20 mg/dL))
Severe low blood glucose or There may be a problem with the test strip
Repeat the test with a new test strip. If the result is LO, contact your healthcare professional immediately.
Blood glucose level is high
Check blood β-Ketone, if checking ketones is part of your diabetes management programme.
General: Result
What It Means
What To Do
Language
Lower than 2.8 mmol/L (Lower than 50 mg/dL)
Low (hypoglycaemic)
Repeat the test with a new test strip, even if you do not feel that you have low blood glucose.
Higher than 16.7 mmol/L (Higher than 300 mg/dL)
High (hyperglycaemic)
Repeat the test with a new test strip, even if you do not feel that you have high blood glucose.
13 ART20287_Rev-A-Man.indd 13-14
Language
What To Do
Language
Language
IMPORTANT: The meter displays results from 1.1–27.8 mmol/L (20–500 mg/dL). Low or high blood glucose results can indicate a potentially serious medical condition.
What It Means
Appears with result which is: Higher than or equal to 16.7 mmol/L (Higher than or equal to 300 mg/dL)
Language
Language
The meter displays results in mmol/L or mg/dL. The unit of measurement is preset. You cannot change this setting.
Display
Language
Low and High Blood Glucose Results
14 11/17/10 3:01 PM
Testing Your Blood β-Ketone
Language Language Language
15 ART20287_Rev-A-Man.indd 15-16
Severe high blood glucose or There may be a problem with the test strip
Repeat the test with a new test strip. If the result is HI, contact your healthcare professional immediately. Check blood β-Ketone, if checking ketones is part of your diabetes management programme.
Note: If you see the error messages E-3 or E-4, consult the Error Messages section in this user’s manual. IMPORTANT: Contact your healthcare professional if you have symptoms that do not match your test result, and you have followed the instructions in this user’s manual.
Important Testing Notes D5
75001
A17
2012/ 03
E.g. Expiry date: March 31, 2012
Language
What To Do
• Use the meter within the test strip operating range • Use the test strip immediately after removing it from the foil packet • Use each test strip only once Do not use expired test strips; they may produce inaccurate results. The expiry date is the last day of the month if only the month and year are shown. Do not put urine on the test strip. Do not use a wet, bent, scratched or damaged test strip. Do not use the test strip if its foil packet has a puncture or tear in it. Note: See test strip instructions for use for operating range and more information on limitations of use.
Check your ketones: • When you have an illness • When your blood glucose is above 16.7 mmol/L (300 mg/dL) • When you are experiencing unusual blood glucose results • When you and your healthcare professional feel it is necessary
Language
Language
Appears when result is: Higher than 27.8 mmol/L (Higher than 500 mg/dL)
What It Means
Language
Display
Language
Meter:
16 11/17/10 3:01 PM
This display always appears when the meter is turned on.
IMPORTANT: Wash your hands with warm soapy water to ensure accurate results. Thoroughly dry your hands. To warm the site, apply a warm dry pad or rub vigorously for a few seconds.
See “Testing Your Blood Glucose” section for more information. Note: Avoid squeezing the puncture site. Time and date (if set) appear next.
Use only fingertip blood samples for blood β-Ketone testing.
Open the foil test strip packet at the notch and tear down to remove the test strip.
Language
4˚C
Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
and the Apply Sample symbols appear, indicating the meter is ready for you to apply a sample to the test strip.
Blood Glucose Sensor Electrode Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
Language
Performing a Blood β-Ketone Test
17 ART20287_Rev-A-Man.indd 17-18
2
Language
Insert the Test Strip With the contact bars (3 black lines) facing up, insert the test strip into the meter until it stops. This turns on the meter. Note: The meter turns off after 3 minutes of inactivity. Remove and reinsert the unused test strip to restart the meter.
Obtain a Blood Sample Select a test site. Use the lancing device to obtain a blood sample. (See lancing device instructions for use for more information.)
Language
Fingertips
Language
Language
Language
Do not use the meter if the display check screen does not exactly match the example. Contact Customer Service.
Language
Test Site
18 11/17/10 3:01 PM
Language Language
The countdown appears on the display as the meter checks your β-Ketone level. Note: Do not remove the test strip from the meter or disturb the test strip during the countdown.
19 ART20287_Rev-A-Man.indd 19-20
Language Language
Language
Hold the blood drop to the white area until the meter beeps (if sound is on) and the status bar appears on the display. This indicates the test strip obtained enough blood.
Language
Language
IMPORTANT: If the countdown does not start, you may not have applied enough blood to the test strip. See test strip instructions for use for re-application instructions. If the countdown still does not start, remove the used strip and discard it correctly. Start a new test with a new test strip.
View the Result The meter beeps (if sound is on) when the result and appears on the display. The test is complete (example shown). The result is stored in memory or you can write it in a logbook. Turn Off the Meter Use the opened foil packet to remove the used test strip. This turns off the meter. Discard the used test strip correctly. Note: You can also press and hold for at least 2 seconds to turn off the meter. The meter also turns off after 60 seconds of inactivity.
Language
Apply Blood to the Test Strip Bring the blood drop to the white area at the end of the test strip. The blood is drawn into the test strip.
20 11/17/10 3:01 PM
Language Language
Blood β-Ketone is expected to be below 0.6 mmol/L.2 High blood β-Ketone may be caused by illness, fasting, vigorous exercise, or uncontrolled blood glucose levels.1-3
Language
Repeat a blood β-Ketone test using a new blood β-Ketone test strip when: • HI appears on the display • Your result is unusually high • You question your result • Your blood β-Ketone result is 0.0 mmol/L, but your blood glucose is higher than 16.7 mmol/L (300 mg/dL)
21 ART20287_Rev-A-Man.indd 21-22
What To Do
Result is between: 0.6 – 1.5 mmol/L and your blood glucose result is: Higher than 16.7 mmol/L (Higher than 300 mg/dL)
High blood β-Ketone
Result remains: 0.6 – 1.5 mmol/L or becomes: Higher than 1.5 mmol/L
You may be at risk of developing diabetic ketoacidosis (DKA)2-6
Contact your healthcare professional immediately.
Very high blood β-Ketone or There may be a problem with the test strip
Repeat the test with a new test strip. If the result is HI, contact your healthcare professional immediately.
Appears when result is: Higher than 8.0 mmol/L
A problem requiring medical assistance may be occurring
Contact your healthcare professional for sick-day management instructions.
Language
IMPORTANT: The meter displays results from 0.0 - 8.0 mmol/L. Consult your healthcare professional before changing your diabetes medication programme.
What It Means
Language
Language
The meter displays results in mmol/L. The unit of measurement is preset. You cannot change this setting.
Display
Language
High Blood β-Ketone Results
Meter:
Language
Understanding Blood β-Ketone Test Results
22 11/17/10 3:01 PM
Language
Contact Customer Service for information on how to obtain control solutions.
Language
23 ART20287_Rev-A-Man.indd 23-24
Language
Do not use control solution past the expiry date. Do not add water or other liquid to control solution. Do not swallow or inject the control solution. Do not use the control solution as eye drops. IMPORTANT: Control solution results should fall within the control solution range printed on the test strip instructions for use. Check that the lot number printed on the test strip packet and instructions for use match.
• Repeat the test if control solution results are outside this range • Stop using the meter if control solution results are continually outside the range printed on the test strip instructions for use. Contact Customer Service
IMPORTANT: Control solution results do not reflect your blood glucose or blood β-Ketone level.
Language
Language
Control solutions may be used with either glucose or β-Ketone test strips. Use control solution: • To practise testing without using your own blood • To confirm that the meter and test strips work together correctly • When you are unsure of your blood glucose or blood β-Ketone test results
• Use only MediSense or Optium Glucose and Ketone control solutions with the meter • Replace the cap securely on the bottle immediately after use
Language
Language
IMPORTANT: When you open a control solution bottle for the first time, count forward 90 days and write this date on the control solution bottle using a pen that won’t smear or wipe off. Throw away any remaining solution after this date.
Important Control Solution Testing Notes
Language
MediSense or Optium Glucose and Ketone Control Solutions
24 11/17/10 3:01 PM
Language
Note: The meter turns off after 3 minutes of inactivity. Remove and reinsert the unused test strip to restart the meter.
This display always appears when the meter is turned on.
Language
Do not use the meter if the display check screen does not exactly match the example. Contact Customer Service.
will appear if performing a β-Ketone control solution
Press to mark the test as a control solution test. The appears. The meter is now ready for you to apply control solution to the test strip. IMPORTANT: The test result will be saved to memory as a blood glucose or blood β-Ketone result if not marked as a control solution test. This may affect your blood glucose averages.
Apply Control Solution to the Test Strip Shake the control solution bottle to mix the solution. Apply a drop of control solution to the white area at the end of the test strip in the area shown. The control solution is drawn into the test strip.
See “Testing Your Blood Glucose” section for more information. Hold the control solution drop to the white area until the meter beeps (if sound is on) and the status bar appears on the display. This indicates the test strip has obtained enough control solution.
Language
and
also appear.
Language
Note: test.
and
Language
Language
Insert the Test Strip With the contact bars (3 black lines) facing up, insert the test strip into the meter until it stops. This turns on the meter.
The Apply Sample symbols
Language
Blood Glucose Sensor Electrode Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
Language
Open the foil test strip packet at the notch and tear down to remove the test strip.
4˚C
Abbott Diabetes Care Ltd. Range Road Witney, Oxon, OX29 0YL Made in UK.
Performing a Control Solution Test
Time and date (if set) appear next.
25 ART20287_Rev-A-Man.indd 25-26
26 11/17/10 3:01 PM
Repeat the test with a new test strip. Follow the testing instructions carefully. Contact Customer Service if the result is still outside the printed range.
Language Language
27 ART20287_Rev-A-Man.indd 27-28
appears with the result if performing a β-Ketone control solution
Language
Language
Note: test.
Language
Language
View the Result The meter beeps (if sound is on) when the result appears on the display. The test is complete (examples shown). The result is stored in memory as a control solution result or you can write it in a logbook as a control result.
Turn Off the Meter Use the opened foil packet to remove the used test strip. This turns off the meter. Discard the used test strip correctly. Note: You can also press and hold for at least 2 seconds to turn off the meter. The meter also turns off after 60 seconds of inactivity.
Language
If the countdown does not start, remove and discard the used test strip, turn off the meter and try again with a new strip.
Language
Note: Do not remove the test strip from the meter or disturb the test strip during the countdown.
Compare the control solution result to the range printed on the blood glucose or blood β-Ketone test strip instructions for use. The result should fall within the range. Causes of out-of-range results include: • The meter and test strips may not be working correctly
The countdown appears on the display as the meter checks the glucose or β-Ketone level.
28 11/17/10 3:01 PM
Language
Press
to turn the meter on.
Language
Start with the meter off (no test strip inserted).
= Blood β-Ketone result = Glucose control solution result
Language
Viewing Test Results in Memory
= Blood glucose result
= Ketone control solution result
Language
This display always appears when the meter is turned on. Do not use the meter if the display check screen does not exactly match the example. Contact Customer Service. See “Testing Your Blood Glucose” section for more information.
Press to review the previous result. Repeat this for each result you wish to review. Note: To exit meter memory at any time, press and hold
Language ART20287_Rev-A-Man.indd 29-30
.
Appear on the display when there are no previous results to view.
Press to return to a previously reviewed result. Repeat this for each result you wish to review. Note: To exit meter memory at any time, press and hold
29
Language
Language
Meter memory stores up to 450 events – control solution, blood glucose, and blood β-Ketone results, and other meter information. The most recent events appear first.
Your most recent result, with time and date (if set) it was obtained, appears next. The following symbols indicate the type of result:
Language
Managing Your Results
.
30 11/17/10 3:01 PM
Language Language ART20287_Rev-A-Man.indd 31-32
Language
Note: n = number of results included in your 7-, 14-, or 30-day average.
Press
to view the 14-day average.
Press
to view the 30-day average.
Press
to return to the 7-day average, or
Press
to return to the memory screen.
Language
Language
31
. Your 7-day average appears.
Press and hold of inactivity.
to turn off the meter. The meter turns off after 30 seconds
Language
Language
IMPORTANT: • Set the date and time before testing to be able to review averages • Averages do not include glucose and β-Ketone control solution results, blood β-Ketone results, and results that do not show time and date • Control solution results not marked as control solution tests may cause averages to be inaccurate • appear on the display when there are no current averages to view • blood glucose test results appear in averages as 1.1 mmol/L (20 mg/dL) • blood glucose test results appear in averages as 27.8 mmol/L (500 mg/dL)
While in memory, press
Language
Viewing Blood Glucose Averages
32 11/17/10 3:01 PM
Message Language
What To Do
The temperature is too hot or too cold for the meter to work correctly
1. Move the meter and test strips to a location where the temperature is within the test strip operating range. (See test strip instructions for use for the appropriate range.) 2. Wait for the meter and test strips to adjust to the new temperature. 3. Repeat the test using a new test strip. 4. If the error reappears, contact Customer Service.
Language
What It Means
Language
Meter error
33 ART20287_Rev-A-Man.indd 33-34
1. Turn off the meter. 2. Repeat the previous testing steps. 3. If the error reappears, contact Customer Service.
The blood glucose level may be too low to be read by the system or There may be a problem with the test strip
1. Review the testing instructions. 2. Repeat the test using a new test strip. 3. If the error reappears, contact your healthcare professional immediately.
The blood glucose level may be too high to be read by the system or There may be a problem with the test strip
1. Repeat the test using a new test strip. 2. If the error reappears, contact your healthcare professional immediately.
Blood was applied to the test strip too soon
1. Review the testing instructions. 2. Repeat the test using a new test strip. 3. If the error reappears, contact Customer Service.
Language
What To Do
Language
Language
Error Messages
What It Means
Language
Message
Transferring test results to a computer requires a compatible data management system. For more information, please go to our website or contact Customer Service.
Language
Transferring Results to a Computer
34 11/17/10 3:01 PM