Operation Manual
39 Pages
Preview
Page 1
AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MEDICAL MONITOR AMM213TD / AMM240WTD Operation Manual
For future reference, record the serial number of your display monitor in the space below : Serial Number The serial number is located on the back of the monitor
AMM213TD/AMM240WTD 1 ENGLISH
back of the monitor
WARNING The title «WARNING» is used to inform the users of possible causes that could inflict the injury, death, or property damage to the patients.
CAUTION The title «CAUTION» is used to inform the users of possible causes that could inflict the patients although it might not severe enough to cause deaths.
NOTE The title «NOTE» is used to inform the users of items that are of importance in terms of installation, operation, or maintenance of the Equipment although the failure does not inflict the bodily harm to the patients.
ADVAN INT’L CORP.2010 All other trademarks are the property of their reference owners. This document is subject to change without notice. Advan provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement. Revision Control Date
Description
REV.F 100810
Document number
2 User’s Guide TABLE OF CONTENTS Product Description and Intended Use... 3 Warnings and Cautions... 4 Symbol Explanations... 7 EU Declaration of Conformity for Medical Applications... 8 Safety Precaution... 9 Cleaning Your Monitor... 9 Power Management Function... 10 Preset Modes... 11 Video Signals... 12 PIP / POP / PBP function... 13 DDC... 14 Installation... 14 Connecting the Power Cord... 15 User Function / Messages... 16 OSD Section... 17 Troubleshooting... 25 Specification of (AMM213TD/AMM240WTD)... 26 Classification... 27 Electromagnetic Compatibility... 28 Dimension Drawing (mm) of AMM213TD... 31 Dimension Drawing (mm) of AMM240WTD... 32 Connectors... 33 Description of Warranty... 34
Product Description and Intended Use AMM213TD/AMM240WTD LCD Monitor is intended to for displaying images from imaging system. Please check the following items are present when you unpack the box, and save the packing materials in case you will need to ship or transport the monitor in future. • AMM213TD/AMM240WTD LCD Monitor and two video cables (1) HD15 VGA cable* (1) DVI-D cable*
*
•
AC Power cord**
•
AC-Adapter
•
Composite Video BNC Jack Cable and Super Video Cable
•
User Manual and 4pcs VESA screws
*Might be optional item, check with local representative **Might vary pending on region standard
*
CAUTION Model No : JMW1150KA2400F04 Part No : PS-52142415001A
ENGLISH
AMM213TD/AMM240WTD 3
4
User’s Guide
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed:
Warning
The personal safety of the patient or physician may be involved. Disregarding this information could result in injury to the patient or physician.
Caution
Special service procedures or precautions must be followed to avoid damaging the instrument.
Note
Special information to make maintenance easier or important information more clear. An exclamation mark within a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the product. A lightning bolt within a triangle is intended to warn of the presence of hazardous voltage. Refer all service to authorized personnel.
Warning
TO AVOID POTENTIAL SERIOUS INJURY TO THE USER AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE, THE USER MUST :
Warranty is void if any of these warnings are disregarded. ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and performance of the equipment only if: • Re-adjustments, modifications, and/or repairs are carried out exclusively by ADVAN Int’l Corp. • The electrical installation of the relevant operating room complies with the applicable IEC and CE requirements. Warning
Federal law (United States of America) restricts this device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM213TD/AMM240WTD monitor has been tested under UL 60601-1 standard and UL listed for Medical application. ADVAN Int’l Corp reserves the right to make improvements in the product(s) described herein. Product(s), therefore, may not agree in detail to the published design or specifications. All specifications are subject to change without notice. Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales representative or agent for information on changes and new products.
1. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment. 2. Carefully unpack the unit and check if any damage occurred during shipment. 3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked 4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the cord, pull it out by the plug. Never pull the cord itself. 6. Test this equipment prior to a medical procedure. This monitor was fully tested at the factory before shipment. 7. Avoid removing covers on control unit to avoid electric shock. manual. 9. Pay close attention to the care, cleaning instructions in this manual. A deviation may cause damage (refer to the Cleaning section). 10. DO NOT STERILIZE MONITOR. 11. Read the entire instruction manual before assembling or connecting the camera. 12. Do not place the monitor or any other heavy object on the power cord. Damage to the 13. Monitor with power supply is suitable for use in patient environment. 14. DO NOT stack more than 8 boxes high 15. The unit should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the unit should be observed to verify normal operation in the configuration in which it will be used. 16. The use of the accessory or cable with the unit other than those specified may result in increased EMISSIONS or decreased IMMUNITY of the unit. This equipment has been tested and found to comply with the limits for medical devices in IEC 601-1-2:2003. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving device. - Increase the separation between the equipment. - Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected.
NOTICES TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The user could lose the authority to operate this equipment if an
ENGLISH
Warnings
AMM213TD/AMM240WTD 5
6
User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet. 2. Use only the proprietary AMM213TD/AMM240WTD power supply for the AMM213TD/AMM240WTD monitor. Make a proper connection by ensuring that the shrink tubing completely secures the connection between the DC power cord and the extension cord. 3. Turn power off when unit is not in use. 4. Never operate the unit right after having transported from a cold location directly to a warm location. 5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently. 6. Handle the monitor with care. Do not strike or scratch the screen. 7. Do not block the monitor cooling vents. The monitor is cooled by natural convection and has no fan. 8. Do not force the monitor past 28 degrees of vertical when adjusting the screen position. (For monitors equipped with stands only.) 9. Remove the power module and connection when transporting the unit. 10. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit. 11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation slots. 13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock. 14. The unit is designed for operation in a horizontal position. Never operate the unit in a vertical position. 15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.) 16. Do not expose the monitor to moisture or excessive dust. 17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standard or the combination should be evaluated. Do not touch the patient with signal input or output connectors. 18. Use only a hospital grade power supply cord. 19. This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable generate uses and can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation, which can be detemined by turing the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving device. • Increase the separation distance between the equipment. • Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected. • Consult the manufacturer or field service technican for help. 20. Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle labeled “Hospital Only” or “Hospital Grade.” Note
To connect to an international power supply, use a an attachment plug appropriate for the power outlet.
Note
Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to ensure EMC. The AMM213TD/AMM240WTD must be installed and operated according to the EMC information provided in this manual.
Dangerous: High Voltage Direct Current Serial Number Top – Bottom Fragile
Do not get wet Consult accompanying documents. Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities. Authorized Representative in Europe Indicates protective earth ground. For indoor use only. Medical Equipment is in accordance with UL 60601-1 and CAN/ CSA C22.2 No. 601.1 in regards to electric shock, fire hazards, 51LJ Medical Equipment and mechanical hazards. E215822 Tested to comply with FCC Class B standards. DC power control switch
ENGLISH
Symbol Definitions
AMM213TD/AMM240WTD 7
8
User’s Guide
EU Declaration of Conformity for Medical Applications A Declaration of Conformity has been filed for this product. A sample of this document may be found in the addendum which accompanied this manual. For a copy of the Declaration of Conformity document, please contact ADVAN Int’l Corp. and request for AMM213TD/ AMM240WTD DOC.
Prepare for Unpack Before you unpack your monitor, prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area which is relatively free of glare from sunlight or other sources of bright light. The monitor is cooled by natural convection (it has no fan). For optimum performance, do not block the cooling vents. While unpacking the monitor, inspect it and other package contents for shipping damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or transportation company and contact customer service for monitor in the future or in case of return. After you unpack the monitor, make sure the following items are included • Monitor with video cable • AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter Model No: JMW1150KA2400F04 Part No: PS-52142415001A
• This operations manual
Note: Your system provider may offer alternative cords or cables depending on the installation requirement and local geography issues.
· Avoid placing the monitor, or any other heavy object, on the power cord to prevent fire or electrical shock from damage to the power cord. · Do not expose the monitor to rain, excessive moisture, or dust to avoid fire or shock hazard. · Do not cover the slots or openings of the monitor for proper heat dissipation. Always put the monitor in a place where there is adequate ventilation. · Avoid placing the monitor against a bright background or where sunlight or other light sources may reflect on the area of the monitor. Place the monitor just below eye level. · Handle with care when transporting the monitor. · Refrain from giving the shock or scratch to the screen, as screen is fragile.
CLEANING YOUR MONITOR No specific liquid or chemical necessary when cleaning this LCD monitor However, we suggest to clean the monitor with non-abrasive cloths and cleaning solutions used in hospitals to clean similar equipment. We recommend using 70% Isopropyl alcohol for the screen surface and warm water and a mild detergent for all other surfaces. Other acceptable cleaning agents are listed below: • 70% isopropyl alcohol • Cidex (2.4% glutaraldehyde solution) • 0.5% Chlorhexidine in 70% isopropyl alcohol To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away Form the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
ENGLISH
SAFETY PRECAUTION
AMM213TD/AMM240WTD 9
10
User’s Guide
POWER MANAGEMENT FUNCTION The monitor is equipped with the power management function which automatically reduce the power consumption when not in use in three power level modes. •
Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the horizontal sync signal is restored. •
Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for about 10 seconds. The power consumption during this is 27 W. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical sync signal is restored. •
Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync signals are off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical and horizontal sync signals are restored. Power Management System The AMM213TD/AMM240WTD Medical Monitor power management proposal. Provides four phases of power-saving modes by detecting the horizontal sync signal as shown in the table below. State
Normal Operation
DPMS Standby
DPMS Suspend
DPMS Off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
Green
Green Flashing (1 sec. Interval)
Green Flashing (1 sec. Interval)
Green Flashing (1 sec. Interval)
Power Consumption
100W
27W
27W
27W
When the monitor is power saving mode or detects an incorrect timing, the screen will be blank and power LED indicator will blink.
PRESET MODES
ENGLISH
AMM213TD/AMM240WTD 11
DVI and VGA input signal formats Horizontal frequency ( KHz )
Vertical frequency ( Hz )
Pixel clock ( MHz )
640 x 350 @70Hz
31.469
70.087
25.175
640 x 480 @60Hz
31.469
59.940
25.175
640 x 480 @75Hz
37.500
75.000
31.500
640 x 480 @85Hz *1
43.269
85.008
36.000
800 x 600 @56Hz
35.156
56.250
36.000
800 x 600 @60Hz
37.879
60.317
40.000
800 x 600 @72Hz *1
48.077
72.188
50.000
800 x 600 @75Hz
46.875
75.000
49.500
800 x 600 @85Hz *1
53.674
85.061
56.250
1024 x 768 @60Hz
48.363
60.004
65.000
1024 x 768 @70Hz
56.476
70.069
75.000
1024 x 768 @75Hz
60.023
75.029
78.750
1024 x 768 @85Hz *1
68.677
84.997
94.500
1152 x 864 @60Hz
54.348
60.053
80.000
1152 x 864 @70Hz
63.955
70.016
94.200
1152 x 864 @75Hz
67.500
75.000
108.000
1280 x 1024 @60Hz
63.974
60.013
108.500
1280 x 1024 @75Hz *1
79.976
75.025
135.000
1600 x 1200 @60Hz
75.000
60.000
162.000
1920 x 1200 @60Hz *2
74.099
59.999
154.125
Resolution
*1 available for AMM213TD *2 available for AMM240WTD
PIP / POP / PBP function
ENGLISH
AMM213TD/AMM240WTD 13
The following combination options are available to you:
VGA
DVI
SDI1
SDI2
C-Video
S-Video
Component / RGBs
VGA
O
O
O
O
O
O
O
DVI
O
O
O
O
O
O
O
O
SDI1
O
O
O
O
O
O
O
SDI2
O
O
O
O
O
O
O
C-Video
O
O
O
O
O
O
O
S-Video
O
O
O
O
O
O
O
O
Component / RGBs
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Main
SOG
PIP
SOG
14
User’s Guide
DDC
To make your installation easier, the monitor is able to Plug and Play with your system if your system also supports DDC protocol. The DDC (Display Data Channel) is a communication protocol through which the monitor automatically informs the host system about its capabilities, for example, supported resolutions and corresponding timing. The monitor supports DDC1 and DDC2B standard.
INSTALLATION To install the monitor to your host system, please follow the steps as given below: Steps 1. Use the supplied video cable (DVI, VGA, S-Video, C-Video) then connect to the host system accordingly. 2. Connect the DC power to the DC power connector on the monitor. 3. Connect one end of AC power cord into the AC Adapter and the other end to AC power outlet. 4. Then turn the host system on and then the monitor. 5. If the monitor still does not function properly, please refer to the troubleshooting section to diagnose the problem.
S - Video
DVI
VGA
SDI IN
IN OUT
DC Power
C - Video / SOG
RGB / Component
SDI OUT
ENGLISH
CONNECTING the POWER CORD
AMM213TD/AMM240WTD 15
* Check first to make sure that the power cord you use is the correct type required for your area. * T his monitor has an universal AC adapter that allows operation in either AC 100 - 240 V ac voltage area. No user-adjustment is required. * Plug one end of the power cord to the AC adapter, plug another end to a proper AC outlet. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use only UL Listed Detachable power supply cord with NEMA configuration 6-15P type (tandem blades) plug cap.
Hospital-grade power cord
Extension power cord (optional) Manufacturer: Bridgepower Part No: CB-47D2004P57MF (15ft) or CB-47D2022P86MF (75ft)
Power Supply Model No: JMW1150KA2400F04 Part No: PS-52142415001A
AMM213TD/ AMM240WTD
16
User’s Guide
User Functions / Messages Key Name and Function Power LED : Lights up to indicate the power is turned ON. Power Switch : To power ON or OFF the monitor. Rotary switch : With the OSD menu activated, increases the value of the selected (Ture Right) parameter or moves rightward in OSD menu. Rotary switch : With the OSD menu activated, increases the value of the selected (Ture Left) parameter or moves leftward in OSD menu. PIP Switch : To enable or disable Picture In Picture function. PBP Switch : To enable or disable Picture By Picture function. POP Switch : To enable or disable Picture On Picture function. Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP, PBP, POP mode. Locker Switch : To turn ON or OFF the system.
How to access the menu 1. Push the “Knob” button to activate the OSD menu. 2. Able to turn left or right the button to select those icons. The icon will be highlighted when is selected. 3. Push the “knob” button to go into the another OSD menu. 4. Turn left or right “Knob” button to increase or decrease the number of selected function. 5. In order to exit from the OSD menu in a different layer, then choose the “Exit option”. In case of long pushing and holding the button around two or three seconds, then it will completely out from the menu regardless wherever you are. 6. Turn the “Knob” button in a fast way to the left or right, while the menu is not activated, then input signal menu will turns up with “V” mark which is chosen current available input signal. You can switch to another input signal source by turning the knob slowly then select the target source by pushing the knob.
AMM213TD/AMM240WTD 17 ENGLISH
OSD Section
Main Menu
Chromatic
Adjust Color Temp, Gamma
Visual
Adjust Brightness, Contrast, Phase, Chroma,
Sharpness-H, Sharpness-V
Setting
Adjust Scale Mode, Color Space, Mirror, Freeze Frame,
Zoom / Pan, PIP, POP, PBP
Advanced
Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock
Information
Adjust Custom Entry, SN, Run Time, Input Format
Exit
Exit the menu
18
User’s Guide
OSD Section
Chromatic
Color Temp
Change the color temperature - D65, D93, S1, S2
Gamma
Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radio graph
Exit
Exit the menu
Visual
Brightness
Adjust the brightness of panel (Range 0 - 100)
Contrast
Adjust the contrast of video (Range 0 - 100)
Phase
Adjust the phase of video (Range 0 - 100)
*available for C and S - video Chroma
Adjust the chroma of video (Range 0 - 100)
*available for C and S - video
Sharpness-H
Set the sharpness of horizontal image (Range 0 - 100)
Sharpness-V
Set the sharpness of vertical image (Range 0 - 100)
Exit
Exit the menu
AMM213TD/AMM240WTD 19 ENGLISH
OSD Section
Setting
Scale Mode
Change the scale mode - Fill all, One to One, Vertical - fill, Horizontal - fill, Fill aspect ratio
Color Space Change color space between RGB and YPbPr *available for Component and RGBS Mirror
Off / On mirror image
Freeze Frame
Off / On freeze frame
Zoom / Pan
Enable zoom - in and pan function
PIP
Enable PIP (Picture In Picture) function
POP
Enable POP (Picture On Picture) function
PBP
Enable PBP (Picture By Picture) function
Exit
Exit the menu
20
User’s Guide
OSD Section
Sub menu of PIP Mode
PIP Mode ON / Off
Source
PIP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI, SOG
Position
PIP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
PIP sub screen size - Small, Medium, Large
Blending
PIP sub screen blending (Range 0 - 100)
Swap
PIP sub screen swap
Exit
Exit the menu
Sub menu of PBP Mode
PBP Mode ON / Off
Source
PBP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI, SOG
Swap
PBP sub screen swap
Exit
Exit the menu