AKRON
AKRON VARITABLE Models 0321H and 0321E User Manual Sept 2003
User Manual
15 Pages
Preview
Page 1
AKRON 0321H, 0321E
Huntleigh Akron, 1 Farthing Road, Ipswich, Suffolk, IP1 5AP, England Tel: +44 (0) 1473 461042 Fax: +44 (0) 1473 462924
792-033-05 1
AKRON 0321H, 0321E
AKRON® VARITABLE Models 0321H, 0321E
USER MANUAL
UM ENGLISH 792-033-05
2
AKRON 0321H, 0321E
Contents 1.
Introduction
2
Warnings, Cautions General Warnings
2 2
2.
Installation
3
3.
Operation
4
4.
Accessories – Operating Instructions
6
Side Extension Knee Block
6 7
5.
Cleaning and Decontamination
8
6.
Troubleshooting
9
7.
Maintenance
9
8.
Warranty and Service
10 11
The
9.
Revision Status
11
10.
Technical Specification
12
11.
Transport and Storage
13
12.
Environmental Protection
13
mark on this product demonstrates conformity with the EC Directive 93/42/EEC.
3
AKRON 0321H, 0321E
1. Introduction Always keep this Operating Manual available for reference.
Warnings & Cautions WARNINGS Warnings identify possible hazards in procedures or conditions which, if not correctly followed, could result in death, injury or other serious adverse reactions.
CAUTIONS Cautions identify conditions or procedures which, if not correctly followed, could result in equipment failure or damage.
General Warnings WARNINGS Use only accessories that have been designed or approved for use with this table. Do not use electric couches in the presence of flammable gasses such as an anaesthetic agent. Maximum Load 180 Kg (396 lbs) distributed evenly. Do not concentrate weight on either side of the table. Plug acts as a disconnect device. Do not allow children to play with the table at any time. Adequately supervise children in the proximity of the table.
4
AKRON 0321H, 0321E
2. Installation Adjustable Foot WARNING Lock castors before adjusting.
A)
Lock castors first.
B)
Adjust foot.
C)
Lock foot by tightening half nut.
WARNING Do not insert the 2-pin mains connector directly into a 3-pin 13A mains outlet. Always use the adapter provided. Plug acts as a disconnect device. Electric Models Use adapter if 3 pin 13A plug is required. (Order reference 5S0409Z)
Ensure mains supply cable is not stretched when connected. Ensure, during couch use, no obstacles are in its path. Ensure hand / foot switch tubes or leads are not trapped by moving parts of the table.
CAUTION When not in use, switch table off.
5
AKRON 0321H, 0321E
3. Operation Elevation Controls WARNING Safely position patient before elevating table. Position all electrical cables away from the moving parts. Position Hand/Foot switch where accidental operation is not possible. Hydraulic Models PUMP PEDAL TO RAISE
Hydraulic Pedal
Electric Models
Press
to raise table.
Press
to lower table.
Handswitch AUF
Press
to raise table. AB
Press
to lower table.
Footswitch
6
LIFT PEDAL TO LOWER
AKRON 0321H, 0321E
3. Operation Wheel Locking WARNING Lock table wheels/castors prior to patient transfer or treatment. The retractable castors are not designed for transportation of patients. Disconnect and coil electrical cord away from moving parts prior to repositioning table.
Castors
Castors Unlocked
Castors Locked
Tilting Mechanism CAUTION Support section while manually altering the angle.
WARNING The table must not be lifted by the Table Top as this may result in damage to the adjustment mechanism. 5 The Table Top must be supported whilst altering the angle.
The tabletop is gas strut assisted and is operated by the release lever positioned centrally under the tabletop. To tilt the top, move the lever towards the table until the top section is free to move. Adjust to the angle required and release the lever to lock the table into the new position. The tabletop can be tilted to from 0º to +80º.
7
AKRON 0321H, 0321E
4. Accessories – Operating Instructions Side Extension WARNING Do not pull on the Extension Leaf as it may become detached from the Top Frame. Care should be taken in the storage of the Extension Leaf when not in use.
A)
Remove the end caps in the top frame.
B)
Slide the extension leaf into the box section on the top frame.
C)
Secure by fitting the retaining straps around the top frame.
8
AKRON 0321H, 0321E
4. Accessories – Operating Instructions Knee Block WARNING Knee Block can only be used with hydraulic tables.
80 Range H Section
Link Bar Locking Knob Knee Block Knee Block Harness Assembly Locking Knob
A)
Place the knee block frame over the link bar as shown.
B)
Secure by using the two locking knobs.
C)
Position bracket over the vertical section of the knee block frame and secure using the locking knob positioned on the side of the adjustment bracket.
D)
To adjust knee block, loosen locking knobs and reposition block accordingly.
E)
Re-tighten knobs once new position is found.
9
AKRON 0321H, 0321E
5. Cleaning and Decontamination WARNING Do not use Alkalis or other organic solvents for routine cleaning. Replace torn or damaged vinyl immediately. Always cover vinyl with fresh paper or sheet between patients. If contamination is known or suspected always decontaminate table before use.
Frequency of routine table cleaning will depend on exact application. CLEANING / DECONTAMINATION 1.
Wear protective clothing: plastic disposable apron and gloves.
2.
Disconnect any mains supply and lock table wheels.
3.
Control handsets can be wiped over using a 70% Isopropranol alcohol wipe.
4.
Prepare a solution of warm water and neutral detergent.
5.
Start at the top of the table and work your way downwards.
6.
Wipe over head end working towards mid torso.
7.
Wipe over remaining horizontal patient surface, working towards foot end.
8.
Wipe all horizontal parts under the patient surface.
9.
Wipe all vertical parts under the patient surface.
10.
Wipe over shroud (if fitted).
11.
Wipe over all parts of wheels.
12.
Ensure all parts of the table are dry before re-use.
13.
Safely discard cleaning materials.
14.
Wash hands thoroughly.
If DECONTAMINATING then repeat steps 1) to 14) using a dilute Hypochlorite / warm water mixture (10,000ppm) instead of warm water and soap. Put table back into service.
10
AKRON 0321H, 0321E
6. Troubleshooting – Electric Actuator Symptom Actuator will not work
Possible cause Power disconnected
Action Ensure mains supply is connected
Fuse blown
Replace fuse in socket
Hand/footswitch disconnected
Check that the hand/foot switch is fully inserted into the actuator
If the problem persists consult your local Akron Supplier.
7. Maintenance Check table visually before use. Carry out routine servicing every six months or more frequently if in heavy use. Routine servicing or repair must only be performed by suitably qualified person.
WARNING Before commencing any maintenance activity, disconnect the table from the electrical supply. Plug acts as disconnect device. Examine the table for any signs of damage. Make sure that all nuts, bolts and other fasteners are tight. Do not over tighten as this may cause binding. Upholstery fasteners should be checked, tightened or replaced if necessary. Check section hinge pins to ensure that no pin protrudes. Check gas strut controls, throughout the full range of movement for locking and assistance. Check hydraulic tables for smooth operation and signs of leakage.
WARNING All electrical checks should be performed by a suitably qualified and licensed electrician. Neither BLUE or BROWN wires are to be connected to the earth terminal of a three pin plug. Examine the flexible cables for cuts, abrasions, kinking or other deterioration and replace if necessary. Ensure that the power supply connector plug is securely attached. Check mains plug connections are tight and fuse is correctly rated (5A). 11
AKRON 0321H, 0321E
8. Warranty and Service (UK only) Huntleigh Healthcare, Akron Products Division’s standard terms and conditions apply to this couch. A copy is available upon request. These contain full details of warranty terms and do not limit the statutory rights of the consumer. For service or maintenance please contact: Service Department Huntleigh Healthcare 310-312 Dallow Road Luton Beds LU1 1TD Telephone: Fax:
01582 745700 01582 745869
For information on this product, regarding warranty and spare parts, please contact: Huntleigh Healthcare Akron Products Division 1 Farthing Road Ipswich IP1 5AP Telephone: Fax:
01473 461042 01473 462924
Huntleigh Healthcare, Akron Products Division A Member of the Huntleigh Technology PLC Group of Companies © Huntleigh Technology PLC 2006. If for any reason your couch is being returned, please inform Huntleigh Healthcare, Akron Products Division prior to sending, and: 1. 2. 3. 4.
Clean the product, as described in the cleaning section. Pack it in suitable packing. Attach the decontamination certificate (or other written statement declaring that the product has been cleaned) to the outside of the package. Mark the package “Service Department”.
Manufactured in the UK by Huntleigh Healthcare, Akron Products Division. As part of the ongoing development programme this company reserves the right to modify specifications and materials of this couch without notice.
12
AKRON 0321H, 0321E
8. Warranty and Service (Outside UK) Huntleigh Healthcare, Akron Products Division standard terms and conditions apply to this table. A copy is available upon request. These contain full details of warranty terms and do not limit the statutory rights of the consumer. For service, maintenance and any questions regarding this, or any other Huntleigh Healthcare, Akron Products Division product, please contact: Huntleigh Healthcare, Akron Products Division 1 Farthing Road Ipswich Suffolk IP1 5AP England Telephone: +44 (0) 1473 461042 Fax: +44 (0) 1473 462924 Huntleigh Healthcare, Akron Products Division A Member of the Huntleigh Technology PLC Group of Companies © Huntleigh Technology PLC 2006. If for any reason your table is being returned, please inform Huntleigh Healthcare, Akron Products Division prior to sending and: 1. 2. 3. 4.
Clean the product, as described in the cleaning section. Pack it in suitable packing. Attach the decontamination certificate (or other written statement declaring that the product has been cleaned) to the outside of the package. Mark the package “Service Department”.
Manufactured in the UK by Huntleigh Healthcare, Akron Products Division. As part of the ongoing development programme this company reserves the right to modify specifications and materials of this table without notice.
9. Revision Status 0321H, 0321E PAGES ALL PAGES ALL PAGES PAGES 11 & 12 PAGES 2 & 7 VARIOUS
ISSUE UM - 01 UM - 02 UM - 03 UM - 04 (DCN958 & 950) UM - 05 (DCN1058)
13
WRITTEN S. Rees S. Rees J. Austin J. Austin J. Barker
DATE 05/05/98 08/01/99 15/11/99 30/10/00 23/09/03
AKRON 0321H, 0321E
10. Technical Specification
Width (cm) Overall Length (cm) Height Range (cm) Max. Load Weight Elevation Control
Akron Varitable 0321H
0321E
71±0.5 152±0.5 50±1.5 98±1.5 180 Kg Hydraulic
71±0.5 152±0.5 50±1.5 98±1.5 180 Kg Electric
Electrical Data 230v Actuator Internal Fuse Rt Current Power Mains Plug Fuse Rt (UK)
220-240v T1.6A x 1 1.6A 480W 5.0A x 1 Electrical Data 115v
Actuator Internal Fuse Rt Current Power
115v F4.0A x 1 3.3A 380W
IEC 601-1 Classification Check serial number label for classification 230v
115v
Double Insulated
Double Insulated
Class 1
Type B equipment
Type B equipment
Type B equipment
Attention consult this manual
Attention consult this manual
Attention consult this manual
14
115v
AKRON 0321H, 0321E
11. Transportation and Storage Handle with care. Do not drop. Avoid shock or violent impact. The equipment should be stored in a clean, dry and well ventilated area. The following limits apply during transport and for a storage period of up to 15 weeks: Ambient temperature Relative humidity Air pressure
-25°C to +70°C 10% to 75% 50 kPa to 106 kPa
The following limits apply to operating conditions or longer periods of storage: Ambient temperature Relative humidity Air pressure
+10°C to +40°C 30% to 75% 70 kPa to 106 kPa
12. Environmental Protection Dispose of unit in compliance with local regulations.
15