Alere

Afinion Analyzers

Afinion 2 Information Codes and Troubleshooting Guide

Guide

2 Pages

AFRICA  AFINION 2 ™  INFORMATION CODES AND TROUBLESHOOTING  Follow the ‘Action to Take’.  Follow the ‘Action to Take’. If unsuccessful, contact Abbott.  i  Note: All documents are available to download. Use the QR codes.  Refer to the file listed in ‘Action to Take’.  INFORMATION CODES CAUSED BY TEST-SPECIFIC LIMITATIONS [#]  CAUSE  ACTION TO TAKE  101  Hematocrit too low  i  Consult the Afinion CRP or Lipid Panel Package Insert.  102  Hematocrit too high  i  Consult the Afinion CRP or Lipid Panel Package Insert.  103  Hemoglobin too low  i  Consult the Afinion HbA1c Package Insert.  104  Hemoglobin too high  i  Consult the Afinion HbA1c Package Insert.  105  HbA1c too low  i  Consult the Afinion HbA1c Package Insert.  106  HbA1c too high  i  Consult the Afinion HbA1c Package Insert.  107  Creatine too high  i  Consult the Afinion ACR Package Insert.  108  Blood in urine  i  Consult the Afinion ACR Package Insert.  INFORMATION CODES CAUSED BY SAMPLE OR TEST CARTRIDGE [#]  CAUSE  201  ACTION TO TAKE  Insufficient sample volume: • Empty capillary • Air bubble in capillary • Capillary incompletely filled  i  Repeat the test with a new sample and test cartridge. Ensure that the capillary is completely filled with no air bubbles (see package insert for the Afinion Test in use).  202  Excess sample on the sampling device exterior  i  Repeat the test with a new sample and test cartridge. Ensure that only the tip of the capillary is in contact with the sample (see package insert for the Afinion Test in use).  203  Wrong sample material  i  Repeat the test with a new sample and test cartridge. Ensure that proper sample material is used (see package insert for the Afinion Test in use, section ‘Specimen Collection and Storage’).  204  Coagulated sample  Repeat the test with a new sample and test cartridge. The time from filling the capillary until analyzing the test cartridge should be as short as possible.  Hemolysed blood sample or poor sample quality  i  Consult the Afinion Package Insert. Repeat the test with a new sample and test cartridge.  Test cartridge or analyzer failure  Repeat the test with a new sample and test cartridge. If the problem persists, restart the analyzer and run controls.  205  Capillary cracked or damaged  Repeat the test with a new sample and test cartridge. Inspect the sampling device before use and handle with care.  206  Barcode label not readable (dirty or damaged)  Repeat the test with a new sample and test cartridge. If the problem persists, restart the analyzer and run controls.  207  • No sampling device inserted • Sampling device belongs to another Afinion Test • Label on sampling device not readable (dirty or damaged)  Repeat the test with a new sample and test cartridge. Ensure that the correct sampling device is in place and that the sampling device label is clean.  208  Test cartridge previously used  Repeat the test with a new sample and test cartridge.  209  Test cartridge has passed expiry date  Check expiry date on the foil pouch or kit container. Repeat the test using a new sample and a new test cartridge from another lot.  The date in the analyzer is incorrectly set  Check the date in the analyzer to make sure it is set correctly. Repeat the test with a new sample and test cartridge.  210  Test cartridge temperature too low  i  211  Test cartridge temperature too high  i  212  Software upgrade is required to run this test  Repeat the test with a new sample and a new test cartridge. Ensure that the operating temperature is within acceptable range (see package insert for the Afinion Test in use). Repeat the test with a new sample and a new test cartridge. Ensure that the operating temperature is within acceptable range (see package insert for the Afinion Test in use). Contact your local supplier for assistance.  i Afinion 2  HbA1c  ACR  CRP  Lipid Panel  8 Demo Videos
File Type: PDF
File Size: 110 KB
File Name: Alere - COL-08147-01 - Afinion 2 Information Codes and Troubleshooting Guide - 2021-12.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions