Quick Reference Guide

2 Pages

BREEZE® Quick Reference Guide This Quick Reference Guide has been produced to assist Healthcare Professionals and other users with only the functional aspects of the system. The guide does not replace the general safety warnings, cautions and recommendations provided in the product instructions for use, part number 624902. Refer to the product instructions for use before using this product. Indications:  •  The Breeze mattress is designed for patients weighing up to 140 kg (308 lb). 1  The Breeze systems are indicated for the prevention and/or management of all categories of pressure ulcer, when combined with an individualised, comprehensive pressure ulcer protocol. Contraindication: Do not use Breeze systems for patients with unstable spinal fractures.  •  Caution: If patients have other unstable fractures, or conditions which may be complicated by a soft or moving surface, advice should be sought from an appropriate clinician before use.  When connected to a suitable power supply the orange Standby light will illuminate. When the Power button is pressed, the green On light illuminates. The Low Pressure indicator will illuminate whenever the pump blower does not deliver the required pressure to the mattress/overlay. An audible alarm will sound until normal pressure is reached or the pump is switched off using the Power button. The indicator will extinguish once normal pressure is reached. Check CPR tubeset is connected properly.  !  The red Power Fail Alarm indicator will flash when a mains power failure has been detected by the pump. An audible alarm will sound until power is resumed or the pump is switched off using the Power button. The Mode Button switches between the three modes, Autofirm, Static and Pulsate. The mode light flashes for a few seconds before the selected mode is activated to allow you to scroll between modes. Once a mode is activated, the light becomes steady. Autofirm Mode provides a firmer surface for patient transfer on and off the bed and allows for easier nursing procedures. Static Mode provides a constant low pressure support surface. Pulsate Mode combines continuous low pressure with periodic pulsation of the support surface. Comfort Adjust provides the means for adjusting the pressure inside the mattress. To increase the firmness of the cells push the up arrow, to decrease push the down arrow. 5  4 3 2 1  The Lock Out Facility prevents accidental alterations being made to the operation of the pump. Pressing both the up and down arrows together deactivates the lock out facility. It is automatically activated 5 minutes after last being unlocked. The On indicator light will flash when activated. The On indicator is continually illuminated when de-activated.  1. NPUAP/EPUAP International Pressure Ulcer Guideline, 2009.
File Type: PDF
File Size: 344 KB
File Name: ARJO Huntleigh Healthcare - 624907EN - ARJOHUNTLEIGH BREEZE Quick Reference Guide Oct 2012 - 2012-10.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions