ARJO Huntleigh Healthcare

ARJOHUNTLEIGH AUTO LOGIC and AURA LOGIC Quick Reference Guide

Quick Reference Guide

2 Pages

AUTO LOGIC / AURA LOGIC Quick Reference Guide This Quick Reference Guide has been produced to assist Healthcare Professionals and other users with only the functional aspects of the system. The guide does not replace the general safety warnings, cautions and recommendations provided in the product instructions for use, part number 630933EN. Refer to the product instructions for use before using this product. Indications: • The Auto Logic® and Aura Logic® mattresses are designed for patients weighing up to 200 kg (440 lb). 1 • The Auto Logic and Aura Logic systems are indicated for the prevention and/or management of all categories of pressure ulcer , when combined with an individualised, comprehensive pressure ulcer protocol. Contraindication: Do not use Auto Logic and Aura Logic systems for patients with unstable spinal fractures. Caution: If patients have other unstable fractures, or conditions which may be complicated by a soft or moving surface, advice should be sought from an appropriate clinician before use.  The red Low Pressure indicator is illuminated whenever the pump detects low pressure within the mattress/seat. An audible alarm sounds unless cancelled by the mute button. The indicator extinguishes once normal pressure is reached. Check CPR is closed and tubeset is connected properly. The yellow Battery Low indicator illuminates two hours before battery failure. One hour before battery failure, the pump The red Power Fail indicator illuminates when a mains power failure has been detected and no battery backup is available. An audible alarm sounds until power is resumed or the pump is switched off using the Run/Standby button. The yellow Service indicator illuminates and remains on after a set number of running hours; this indicates that the pump is ready for a service. The pump continues to function normally even when the service indicator is illuminated. If During an alarm condition (except Power Fail Alarm), the sound of the alarm can be muted by pressing this button. The yellow indicator then remains on but the alarms are muted for 15 minutes or until the alarm condition has been corrected. Selects the Reactive (Constant Lower Pressure) (CLP), non-alternating mode. The yellow indicator illuminates when the pump is in this mode. When the Active (Alternating) mode (default) is selected, the yellow indicator is switched off. Press this button for approximately 4 seconds to activate the Reactive (CLP) Mode. The change in the mode will occur at the end of the next complete alternating cycle, and so a maximum 10 minute delay may be experienced.  Control LEDs are illuminated. This operation will not function whilst a seat cushion is connected. The mattress/seat cell pressure can be manually adjusted for patient comfort using the buttons on the pump control panel. The pressure setting is indicated by the green indicator to the left of the buttons.  Accessories Battery Pack (Part No. BBP600) CAUTION: The battery pack is not suitable for use in the homecare environment. 1. NPUAP/EPUAP International Pressure Ulcer Guideline, 2009.  Aura Logic Seat Cushion (Part No. PXS001)
File Type: PDF
File Size: 1.07 MB
File Name: ARJO Huntleigh Healthcare - ARJOHUNTLEIGH AUTO LOGIC and AURA LOGIC Quick Reference Guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions