ARJO Huntleigh Healthcare
Enterprise 5000 Quick Reference Guide Dec 2012
Quick Reference Guide
2 Pages
Preview
Page 1
Enterprise 5000
Quick Reference ®Guide ENTERPRISE 5000
QUICK REFERENCE GUIDE IMPORTANT! This Quick Reference Guide (QRG) is intended to assist the user in understanding the basic functions of this product. The QRG does not replace the safety warnings, cautions and other important information provided in the Instructions for Use (IFU) supplied with the equipment; copies of the IFU are available on request from ArjoHuntleigh. Some of the functions should only be used by clinically-qualified personnel. The carer should make sure they have read and understood the IFU before using this equipment. This product is intended for patients over 12 years of age. A clinically-qualified person should assess the age, height and medical condition of the patient to ensure they can use the product safely. Place the mattress platform in the low height position when the patient is unattended.
Removable Plastic Deck Sheets
Removable Head and Foot Ends
Patient Control Angle Indicator
Safety Side Attendant Control Panel (ACP)
CPR Lever
Roller Buffers
Safety Side Release
Duvet / Linen Holder
Bed Extension Button
Mattress Retainer Brake Pedal
Technical data Safe working load (SWL)
250kg / 550 lbs.
Attendant Control Panel (ACP)
Height button. For Standard low height – select the function button then press the lower button. For Extra low height – press and hold the function button and lower button simultaneously.
CPR – Hold down button to return the bed to a flat position. CPR button works even if functions are locked out.
Under bed lighting ON / OFF
Calf section selection buttons – One of these two buttons will be selected at all times. Whichever button is selected will determine the position the calf section profiles into from flat. Fowler position
Vascular position
Backrest Calf section
Raise button Lower button
Tilt
• Yellow light indicates function is locked out • Green light indicates function selected
Knee-break
Function selection buttons – select the function you want then press the raise or lower button to adjust that function
Patient control
Lock / Unlock Function button. Press the lock button then the function(s) you want to lock out. To unlock use the same sequence. To lock all functions at once, press and hold down the lock button for five seconds.
Raise button
1. Select one of the function buttons. Auto-Contour, Backrest or Knee-break.
Lower button
2. The indicator light on the selected function will turn green. If the indicator light is yellow, that means the function has been locked out at the Attendant Control Panel.
Bio-Contour raises backrest and kneebreak simultaneously
3. Press Lower or Raise button to adjust that function.
Knee-break Backrest
• Yellow light indicates function is locked out • Green light indicates function selected
ENTERPRISE® 5000 TROUBLESHOOTING
If you experience any problems when using this product: 1. Refer to the instructions for use (part no. 746-445) for further information. 2. Check the troubleshooting guide in the product service manual (part no. 746-446). 3. Call the ArjoHuntleigh UK 24 Hour Helpline on 08457 342000.
ArjoHuntleigh AB Verkstadsvägen 5 241 38 Eslöv SWEDEN www.ArjoHuntleigh.com
815-502-1 12/2012