ARJO Huntleigh Healthcare

Huntleigh Nimbus 3 Quick Reference Guide Jan 2005

Quick Reference Guide

2 Pages

MRF-105 Nimbus® 3 Quick Reference Guide (For more detailed instructions, refer to the User Manual)  FIRM SOFT  LOW HIGH PRES MUTE  SURE  ER POW  PRES  FORT COM ROL CONT  SURE  ER POW T FAUL  WAIT  3 BUS  IC STAT  ®  POWE  R  NIM  IC AM DYN TEM ED SYS ANCION D™ ADV TAT GUAR D FLO HEEL ORPA ing:® SENS  I o  porat -Matt IncorAuto and  SET ON/RE ALARM  POWER  NIMBUS 3 ®  I o  ADVANCED DYNAMIC FLOTATION SYSTEM  ON/RESET ALARM  Incorporating: HEELGUARD™ and Auto-Matt® SENSORPAD  STATIC  HIGH  LOW  PRESSURE  PRESSURE  MUTE POWER WAIT  SOFT FIRM COMFORT CONTROL  PUMP FAULT  I o  Power Switch & Alarm Reset  Switches the mains power to the pump on and off. When the pump detects an alarm condition, it can be cancelled by switching the pump off and then back on.  Wait  The Wait indicator is illuminated when the mattress is being inflated. The indicator will remain illuminated until the mattress has been fully inflated. This may take up to 15 minutes.  Alarms  During an alarm condition the triangular alarm symbol will flash, an audible alarm will sound and one of the following indicators will be illuminated: Low Pressure, High Pressure, Pump Fault, Power (Fail).  LOW PRESSURE  Low Pressure  The Low Pressure indicator is illuminated whenever the pump detects low pressure within the mattress. An audible alarm will sound unless cancelled by the Mute button. The indicator will extinguish once normal pressure is reached. Make sure the CPR is closed, the tubeset is connected properly and the mattress is set to Normal.  HIGH PRESSURE  High Pressure  The High Pressure indicator is illuminated whenever the pump detects high pressure within the mattress. An audible alarm will sound unless cancelled by the Mute button. The indicator will extinguish once normal pressure is reached. Make sure the tubeset is not kinked and the Auto-Matt® sensor pad is flat and not kinked.  Pump Fault  Internal pump malfunction. Call Service Engineer. (Rental equipment only).  Power  The Power (Fail) alarm indicator will illuminate when a mains power failure has been detected. An audible alarm will sound. The alarm will continue until the mains power is resumed or the pump is switched off using the Power switch on the pump. If the power failure is prolonged, switch to Transport mode and disconnect the tubing. Examples of the Power (Fail) alarm are mains lead removal and power failure.  Maintenance/ Service  The telephone symbol will illuminate and remain on after a set number of running hours indicating the pump is ready for a service. The pump will continue to function normally while the telephone symbol is illuminated.  MUTE  Alarm Mute  During an alarm condition the audible alarm can be muted by pressing the Mute button. The indicator on the Mute button will illuminate to show the audible alarm has been silenced. After approximately 15 minutes the alarm mute will be cancelled, and the audible alarm will sound.  STATIC  Static  Press the Static button to select static mode. An audible tone will sound when the button is pressed. The indicator on the Static button will only illuminate when the pump is in static mode. Press the button again to return to alternating mode.  Comfort Control  The mattress cell pressure can be manually adjusted for patient comfort using the rotary Comfort Control dial.  WAIT  PUMP FAULT  POWER
File Type: PDF
File Size: 6.95 MB
File Name: ARJO Huntleigh Healthcare - Huntleigh Nimbus 3 Quick Reference Guide Jan 2005 - 2005-01.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions