Quick Reference Guide
2 Pages
Preview
Page 1
MRF-105 Nimbus® 3 Quick Reference Guide (For more detailed instructions, refer to the User Manual)
FIRM SOFT
LOW HIGH PRES MUTE
SURE
ER POW
PRES
FORT COM ROL CONT
SURE
ER POW T FAUL
WAIT
3 BUS
IC STAT
®
POWE
R
NIM
IC AM DYN TEM ED SYS ANCION D™ ADV TAT GUAR D FLO HEEL ORPA ing:® SENS
I o
porat -Matt IncorAuto and
SET ON/RE ALARM
POWER
NIMBUS 3 ®
I o
ADVANCED DYNAMIC FLOTATION SYSTEM
ON/RESET ALARM
Incorporating: HEELGUARD™ and Auto-Matt® SENSORPAD
STATIC
HIGH
LOW
PRESSURE
PRESSURE
MUTE POWER WAIT
SOFT FIRM COMFORT CONTROL
PUMP FAULT
I o
Power Switch & Alarm Reset
Switches the mains power to the pump on and off. When the pump detects an alarm condition, it can be cancelled by switching the pump off and then back on.
Wait
The Wait indicator is illuminated when the mattress is being inflated. The indicator will remain illuminated until the mattress has been fully inflated. This may take up to 15 minutes.
Alarms
During an alarm condition the triangular alarm symbol will flash, an audible alarm will sound and one of the following indicators will be illuminated: Low Pressure, High Pressure, Pump Fault, Power (Fail).
LOW PRESSURE
Low Pressure
The Low Pressure indicator is illuminated whenever the pump detects low pressure within the mattress. An audible alarm will sound unless cancelled by the Mute button. The indicator will extinguish once normal pressure is reached. Make sure the CPR is closed, the tubeset is connected properly and the mattress is set to Normal.
HIGH PRESSURE
High Pressure
The High Pressure indicator is illuminated whenever the pump detects high pressure within the mattress. An audible alarm will sound unless cancelled by the Mute button. The indicator will extinguish once normal pressure is reached. Make sure the tubeset is not kinked and the Auto-Matt® sensor pad is flat and not kinked.
Pump Fault
Internal pump malfunction. Call Service Engineer. (Rental equipment only).
Power
The Power (Fail) alarm indicator will illuminate when a mains power failure has been detected. An audible alarm will sound. The alarm will continue until the mains power is resumed or the pump is switched off using the Power switch on the pump. If the power failure is prolonged, switch to Transport mode and disconnect the tubing. Examples of the Power (Fail) alarm are mains lead removal and power failure.
Maintenance/ Service
The telephone symbol will illuminate and remain on after a set number of running hours indicating the pump is ready for a service. The pump will continue to function normally while the telephone symbol is illuminated.
MUTE
Alarm Mute
During an alarm condition the audible alarm can be muted by pressing the Mute button. The indicator on the Mute button will illuminate to show the audible alarm has been silenced. After approximately 15 minutes the alarm mute will be cancelled, and the audible alarm will sound.
STATIC
Static
Press the Static button to select static mode. An audible tone will sound when the button is pressed. The indicator on the Static button will only illuminate when the pump is in static mode. Press the button again to return to alternating mode.
Comfort Control
The mattress cell pressure can be manually adjusted for patient comfort using the rotary Comfort Control dial.
WAIT
PUMP FAULT
POWER
Installation
Quick Start
Nimbus 3 Mattress Replacement (MR)
When the Nimbus 3 pump is switched on using the Power switch, the pump will run a self diagnostic check for approximately 3 seconds during which all indicators will be illuminated. The Wait and Low Pressure indicators will remain illuminated while the mattress inflates. Allow approximately 15 minutes for the mattress to inflate fully. Once the mattress is fully inflated, the Wait and Low Pressure indicators will extinguish. Place a bed sheet over the mattress and tuck in loosely. Once the patient is on the mattress, the pump will automatically sense and adjust the pressure in the cells to support the patient.
Place the MR directly onto the bed base, with the tubeset and CPR located at the foot end of the bed. The cells of the mattress must be uppermost. Use the hook and fastener straps provided to attach the MR to the bed frame. If the bed is to be gatched (profiled), attach the mattress to the movable part of the bed only. To complete mattress installation Zip the protective cover over the mattress. Make sure that the Huntleigh logo is uppermost and at the foot end of the mattress. Check that the transport control is set to NORMAL and the CPR control is closed and locked in position.
Transport Mode To transport a patient using the Nimbus 3 mattress, turn the transport control at the foot end of the mattress clockwise to Transport (See Figure 1). Switch off the pump and disconnect the tubeset. The patient will remain supported by the mattress for at least 12 hours. To resume normal operation, reconnect the pump, turn the transport control counterclockwise to Normal (See Figure 2) and switch on.
NORMAL NORMAL
NORMAL
TRANSPORT
TRANSPORT
Figure 1
Figure 2
TRANSPORT
Make sure the CPR unit and mains power cord are clear of gatching (profiling) bed mechanisms or other possible entrapment areas. The CPR must be accessible at all times. If the pump is to be hung from the end of the bed, attach the bed bracket to the bed frame.
CPR Control IN THE EVENT OF CARDIAC ARREST In the event of a patient suffering cardiac arrest and CPR needing to be administered:
Make sure the mattress tubeset is not "kinked" or twisted and connect it to the pump until it clicks into place. Make sure the tubeset is securely connected to the pump and the mattress.
To Activate the CPR 1. Lift the red handle on the control panel at foot end of the mattress. FAST DEFLATE
CP
2
NORMAL
R 1
To Connect Tubeset
To Disconnect Tubeset
TRANSPORT
2
3
2. Turn the handle counterclockwise.
1 2
NORMAL
FAST DEFLATE
1
CP
Some of the older Nimbus 3 Systems may have the old style tubeset. If this is the case DO NOT fit as above. Instead see below.
R 1
TRANSPORT
2
3
1 1
3. Pull the handle away from the panel. To Connect Tubeset
To Disconnect Tubeset
FAST DEFLATE
NORMAL
1
2
CP
TRANSPORT
R
2
2
3
On older Nimbus 3 pumps insert the mains power connector into the socket on the side of the pump (newer pumps are hard-wired). Connect the mains power cable to a suitable mains power outlet. SAFETY SIDES Regarding the use of safety sides, always refer to your local trust policy AND the product user manual.
4. The triangular seal will rotate and air will exhaust from the mattress. The torso area of the mattress will deflate in less than 10 seconds. To Reset the CPR 1. Turn the grey triangular seal clockwise and push onto the connectors. 2. Turn the red handle clockwise. 3. Fold the handle flat to lock in position.
Huntleigh Healthcare Ltd. A Huntleigh Technology PLC Company, 310-312 Dallow Road, Luton, Bedfordshire, LU1 1TD Telephone: 01582 413104 Fax: 01582 459100, Sales Enquiries Telephone: 01582 745700 Fax: 01582 745745, Huntleigh Rentals 24 hour Helpline Lo-call 08457 342000 Website: www.huntleigh-healthcare.com E-mail: [email protected] ® and ™ are trade marks of Huntleigh Technology PLC. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice. Registered No: 942245 England, © Huntleigh Technology PLC 2004
151912EN_01 01/05