ARJO
Citadel Plus Quick Reference Guide - Controls Rev C
Quick Reference Guide
2 Pages
Preview
Page 1
QUICK REFERENCE GUIDE - CONTROLS
Citadel Plus Attendant Control Panel
Nurse Control Panel
Patient Handset
Patient Control Panel
Power On Indicator Battery Status LED Indicator
Thigh Section - Raise or lower the thigh section.
Battery fully charged Battery charging
Calf Section - Raise or lower the calf section.
Battery discharged
Anti-Entrapment System (AES) Indicator - When illuminated, AES system has been activated and obstruction needs to be removed before the frame will lower. Mattress Platform Height - Raise or lower the mattress platform.
Backrest Angle - Raise or lower the backrest.
831.414-EN Rev C • 05/2020 • Page 1/2
Lower head end (Trendelenburg position)
Lower foot end (Reverse Trendelenburg position) CPR Position - Flattens the mattress platform and lowers the bed height Function Lockout - Press the button, then press selected Attendant Control Panel button(s) to lock or unlock function. Yellow light = locked.
Sound on/off (mute) (available on selected models)
Auto-Chair (nurse control panel only) - Press and hold for chair position.
Volume down (available on selected models)
Auto-Chair Down (nurse control panel only) - Press and hold to return to flat level position.
Volume up (available on selected models)
Under Bed Light (nurse control panel only)
Channel down (available on selected models)
Nurse Call (available on selected models) - Press to request assistance.
Channel up (available on selected models)
Reading lamp (available on selected models)- Press to turn on light.
Television on/off (available on selected models)
Reading lamp on/off (available on selected models)
Closed caption on/off (available on selected models)
Weigh Scale Control Panel Max 522 kg (1150 lb) Approval No. UK2823 2009/23/EC Max 522 kg Min 10 kg e = 500 g
.
Zero - Press to reset weighing system when bed is first set up and before a new patient is placed on the bed. Auto Compensation - Press when adding or removing items from the bed without affecting the indicated patient weight. Weigh - Press to display weight.
Select Units - Press to select weighing unit. VariZone Mute Button - Press to mute exit alarm for three minutes.
ArjoHuntleigh AB Hans Michelsensgatan 10 211 20 Malmö, Sweden www.arjo.com
Patient movement detection threshold An indicator shows the selected sensitivity of patient movement.
.
In Bed - Press to reactivate or activate patient movement detection and increase sensitivity.
Egress - Press to reactivate or activate patient movement detection and decrease sensitivity.
831.414-EN Rev C • 05/2020 • Page 2/2