AtriCure Inc

Tender LiV Care (TLC) Care and Handling Guide

2 Pages

Tender LiV™ Care (TLC)  Catalog Number 340-8230, 340-8250, 340-7450, 340-7451, 340-7470, 340-7498, 340-7499, 340-7495, 340-7850, 340-7475, 340-7480, 340-7484, 340-7485, 340-7486, 340-7800, 340-7800S, 340-7800L, 340-7802, 340-7802S, 340-7802L, 340-7803, 340-7803S, 340-7803L, 340-7805, 340-7805S, 340-7805L, 340-7806, 340-7806S, 340-7806L, 340-7820, 340-7820S, 340-7820L, 340-7821, 340-7821S, 340-7821L, 340-7824, 340-7824S, 340-7824L, 340-7824NM, 340-7825, 340-7825S, 340-7825L, 340-7830, 340-7830S, 340-7830L, 340-7831, 340-7831S, 340-7831L, 340-7835, 340-7835S, 340-7835L, 340-7840, 340-7840S, 340-7840L, 340-7862, 340-7862S, 340-7862L  BEFORE THE PROCEDURE  Storage Transport  DURING THE PROCEDURE  Preparation Storage  AFTER THE PROCEDURE  Cleaning and Sterilization  Before the Procedure Reference: Instructions for Reprocessing of Reusable Devices, P/N 440-11975-01 • Store instruments in the proper tray at all times • Transport instruments in tray to avoid damage • Test function prior to use Contact Customer Service for replacements European Representative: Köntges SPRL Avenue Hellevelt 35 B-1180 Brussels Belgium Tel: +32 (0) 2 375 51 63 FAX: +32 (0) 2 375 89 06 e-mail: herbert.kontges@skynet.be  Manufactured by: 7555 Innovation Way Mason, Ohio 45040 USA Customer Service: 1-866-349-2342 (toll free) 1-513-755-4100 (phone)  During the Procedure • Flush instruments with saline periodically • DO NOT ALLOW BLOOD TO DRY ON INSTRUMENTS After the Procedure CAUTION! • Avoid caustic cleaners Cleaning solutions should be pH neutral • Avoid automated washers Instruments should be hand washed • Avoid tap water Use DI or RO water only • Avoid wet loads Instruments must be dry when stored Prior to Sterile Processing Department (SPD) • Hand rinse and flush with sterile water • Send to Sterile Processing Department (SPD) immersed in sterile water Cleaning at Sterile Processing Department (SPD) • Fill sink with Enzymatic Cleaner and de-ionized (DI) or reverse osmosis filtered (RO) water to manufacturer specifications • Immerse entire instrument in the sink • Using syringe with flush port adapter attached, flush instrument 2x or until no debris is seen exiting the instrument • Using soft cleaning brush, scrub jaws of instrument until clean LiV™ Care and Handling Guide  Page 1 of 2  P/N 490-13978-01 Rev G
File Type: PDF
File Size: 146 KB
File Name: AtriCure Inc - 490 - 13978 - 01 - Tender LiV Care (TLC) Care and Handling Guide - Rev G.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions