B.Braun Medical

Infusion Systems

Infusomat Space Volumetric Quick Reference Guidelines Sw F, G.H and J Sept 2014

Quick Reference Guidelines

14 Pages

Standby Mode:  Quick Reference Guidelines for Infusomat® Space  Infusomat® Space Volumetric - Quick Reference Guidelines  1. Stop the infusion by pressing . 2. Press once to access the Standby Function.  Clear button Parameter Setting Keys  3. Answer YES with arrow key to “Use standby?” • Standby will now be activated with previously used standby time.  4. To change the desired duration the pump goes into standby press  Bolus button  Scroll menus, change/enter values  On/Off button  arrow key.  Ok button Door Open button  To confirm settings  5. Use the directional keypad  to change the time or press  to clear and start from zero.  Start/Stop Space Connect button To link the pump to space control/ barcode scanner  6. Once desired time has been chosen press to confirm. • The pump will now start to count down the desired standby time. • Standby mode can be cancelled at any time by pressing  .  ! If the giving set is in-situ the pump cannot be switched off. Í  Standby is activated after pressing  for 3 seconds.  Software F/G/H/J  BOLUS/ STANDBY MODE  Data Lock:  Quick Reference Guidelines for Infusomat® Space  ! If your pump is configured to prime the line press Í  to prime and repeat as necessary. Ensure the pump is disconnected from the patient before priming.  1. From the Main Menu use the to scroll down to the Options Menu. 2. Once the Options Menu is highlighted press to access. 3. Use the  arrow keys to highlight Data Lock and press  4.  Use the and then press  Starting an infusion:  Quick Reference Guidelines for Infusomat® Space  to access.  1. *Enter the Volume To Be Infused “VTBI” by using 2. In the Main Menu  to set Data Lock at Level 1 or Level 2  , and confirm with highlight rate with  .  and select with  .  .  LEVEL ONE will allow the user to start and stop the infusion, change the disposable, and turn the pump off. All other actions will require the code. LEVEL TWO will only allow the user to stop the infusion. All other actions require the code. 5. Activate Data Lock by using the directional keypad to input the 4 digit code: ! Once activated any changes need to be made within 20 seconds. After this, a key symbol appears on the screen. At this point any further changes to infusion parameters will require the code.  Í  3. Select the correct rate with . 4. Press to commence infusion. • Once VTBI and Rate parameters are entered, the Time is automatically calculated. • Moving arrows on the display plus a green operating light indicate the pump is infusing. ! Check the displayed values with the values intended. Start only if values correspond. Í  • * You do not need to enter a Volume To Be Infused if you have a drop sensor connected.  6. De-activate the Data Lock by following steps 1 to 5 and returning the Data Lock level to OFF. PRESSURE SETTINGS/  STARTING THE  DATA LOCK  INFUSION  Quick Reference Guidelines for Infusomat® Space  Change infusion set:  • Interrupt connection to the patient to avoid dosage errors during line change. • Never leave the pump unattended during a line change. • Pump must be powered ON to change the giving set. 1. Press to stop infusion. • Ensure the roller clamp is closed on the giving set; disconnect from the patient.  19981_Infuso_SETUP_Layout 1 19/02/2013 11:12 Page 2  2. Press and to open the pump door. 3. Pull door down to open. 4. Press the green opening lever of the anti-free flow device within the pump.  5. Remove set and replace with a new line. 6. Press pump door firmly to close. ! Check the displayed values with the values intended. Start only if values correspond. Í  This booklet is provided for reference only. Prior to operating this equipment all users should consult the full Instructions For Use.  B. Braun Medical Ltd | Hospital Care | Thorncliffe Park | Sheffield | S35 2PW Tel: 0114 225 9000 | Fax: 0114 225 9111 | www.bbraun.co.uk  XX-SIIFUM-09-14  CHANGING RATES/ SYRINGE
File Type: PDF
File Size: 2.92 MB
File Name: B.Braun Medical - Infusomat Space Volumetric Quick Reference Guidelines Sw F, G.H and J Sept 2014 - 2014-09.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions