Operating Manual BaehrTec A700
BaehrTec A700 Dry technology pedicure device with handpiece for cosmetic applications
Operating Manual
English – V100 – Last update: 09/2018
Page 1/60
Operating Manual BaehrTec A700
1
Table of Contents Page Table of Contents ... 2 Note to users ... 4
1 2 2.1 2.2
Manufacturer’s declaration regarding this operating manual... 5 Symbols ... 5 2.2.1 2.2.2 2.2.3
2.3 2.4
Symbols in this operating manual... 5 Type plate with performance specifications ... 6 Symbols on the packaging ... 7 Foreword ... 8 General product description and intended use ... 9
2.4.1 2.4.2 2.4.3
Operator requirements... 9 Employee and Customer Protection ... 10 Possible risks for customers ... 10
2.4.3.1 2.4.3.2 2.4.3.3 2.4.4
Possible risks for operators ... 11
2.4.4.1 2.4.4.2 2.4.4.3 2.4.5 3
Risks due to dust and removed materials ... 11 Risk due to moving or rotating parts/instruments ... 11 Allergy risks... 11 Risks due to dust and removed materials ... 11 Risk due to moving or rotating parts/instruments ... 11 Allergy risks... 12 Safety information ... 12
Before using the device for the first time ... 12 3.1 3.2
4
Scope of delivery ... 12 What to observe before every use! ... 13 Device description ... 18
4.1
Control unit description ... 18 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7
4.2 4.3 4.4 4.5
Front view BaehrTec A700 ... 18 Side view with handpiece holder ... 19 Side view with dust bag lid (closed) ... 20 Side view without dust bag lid and turbine protection filter (open)... 21 Dust bag lid (interior) ... 22 Rear view ... 23 Bottom view ... 24 Handpiece description ... 25 Cold device connection cable description ... 27 Suction system description ... 28 Colour display ... 30
4.5.1 4.5.2 4.6 4.7 4.8
Work mode... 30 Adjustment mode (Options Menu) ... 31 Home Function (button (17)) ... 33 Memory buttons (buttons (29) - (30)) ... 33 Attaching/detaching the dust bag lid to the control unit ... 34
4.8.1 4.8.2 4.9
Detaching ... 34 Attaching ... 34 Changing the filter ... 35
4.9.1 4.9.2 Page 2/60
Changing the dust bag... 36 Changing the turbine protection filter ... 37 English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
4.9.3 4.10 4.11 5
Servicing and care ... 46 5.1 5.2
Safety information ... 46 Care (cleaning and disinfection)... 47 5.2.1 5.2.2
5.3 5.4 5.5
Cleaning the handpiece button ... 47 Easy-Clean clamping mechanism ... 49 Warranty ... 52 Recycling/disposal ... 52 Self-help in the event of malfunctions ... 53
5.5.1 5.5.2 6 7
Changing the filters ... 38 Getting started ... 40 Instrument changing aid (insertion and removal aid for very small instruments) 43
Change fuses ... 55 Changing the dampers for the handpiece sleeve... 55
Technical specifications ... 58 Spare parts/accessories ... 60
English – V100 – Last update: 09/2018
Page 3/60
Operating Manual BaehrTec A700
2
Note to users
This operating manual must be read thoroughly before using the device for the first time and the instructions and specifications contained therein must be precisely observed. This operating manual is an integral part of the device. By reading it thoroughly, you will be fully familiarized with the functioning and operation of the device and therefore, will be able to recognize and avoid operating errors, dangers and damage. Please retain this operating manual in a safe place with the device. Should you lose the A700 operating manual, you can reorder it from us at any time. You can find our contact address under “Contact address & Manufacturer”.
Please read this operating manual carefully. Please keep this operating manual for reference purposes – also in case you wish to clean the device. Please observe all warnings and instructions in this operating manual and on the device. If you ever clean the device, the power supply must be fully disconnected. Remove the power plug from the safety outlet. When cleaning / disinfecting, please observe the notes described in chapter 5 and its subchapters. Do not place the device near heat sources, such as radiators, air-conditioning units, refrigerators and the like. Please also avoid positioning it near water sources (for example sinks) and / or chemicals. Ensure an appropriately hygienic environment. Place the device on a firm, non-slip base. Avoid placing it on unstable tables, carts or the like. If the device falls down, this can cause severe damage and injuries. To ensure a reliable functioning of the device, protect it from cold as well as from overheating. At the same time, avoid temperatures below +10°C and above +35°C. Should you use an extension cable, ensure that the overall power supply is not higher than the capacity of the extension cable. Please understand that we cannot accept any liability for accessories of any kind, which are not included in the scope of delivery. This also applies to any possible consequential damages that may occur. Please avoid:
touching plug contacts with sharp and / or metal objects. placing water, beverages and other liquids in the direct vicinity of the device. leaving children unsupervised with the device. touching the power plug with wet and / or damp hands.
Please do not carry out any repairs on the device yourself, as this will result in the cancellation of the guarantee claim. For all repairs, please contact qualified experts authorized to conduct such work. If necessary, please ask the manufacturer or the distributor of the device (see label on the device).
There are no known electromagnetic interactions, which can occur between the BaehrTec A700 and other devices.
Page 4/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
Please do not use the device in the following cases and contact the manufacturer:
If the power cable / insulation shows signs of damage. If the device was exposed to moisture and / or wet conditions. If the device has been dropped and / or the device housing is damaged.
The device may be damaged in the event of a stroke of lightning and / or surge. Therefore, we also recommend installing surge protection and removing the plug during a storm and / or during a long period of non-use, in order to protect the device from voltage peaks. Please observe the customary power supply specifications before connecting the device to the mains and check whether or not they correspond to the information on the type plate. 2.1
Manufacturer’s declaration regarding this operating manual
Dear customer, The Gustav Baehr GmbH created this operating manual with great diligence. Nevertheless, it cannot be ruled out that some sections may contain inaccuracies or that some things are not described. Therefore, we kindly ask you to inform us if you detect any errors or inaccuracies. There is no liability on the part of the Gustav Baehr GmbH for errors in this operating manual or possible consequential damages resulting therefrom, which arise from the provision or use of this operating manual while using the BaehrTec A700. The Gustav Baehr GmbH reserves all rights to change/amend this operating manual. A circulation or amendment of this operating manual is prohibited without the prior explicit approval of the Gustav Baehr GmbH. 2.2
Symbols
2.2.1
Symbols in this operating manual
Warning! This symbol indicates a danger to humans or the device. This symbol must always be given the utmost attention. Read the relevant sections with particular diligence and strictly follow the instructions.
This symbol provides particularly useful advice and gives additional information on operating the device.
CE mark (Communauté Européenne)
English – V100 – Last update: 09/2018
Page 5/60
Operating Manual BaehrTec A700
2.2.2
Type plate with performance specifications
Fig. 1
CE mark (Communauté Européenne)
It is a mandatory requirement that this operating manual is read and observed before using the device.
Electrical/electronic waste. Devices with this label must be disposed of professionally and cannot be discarded of with household waste.
This symbol indicates which fuse(s) is/are used in the device.
Protection class II This is a device of protection class II with functional earthing. ON (max) / OFF (min) Indicates how the device should be operated. The following applies to the device: Operating time: 15 min (maximum) pause time: 10 min (minimum) These approved operating times correspond to the common work procedure in foot care treatment.
Functional earthing This symbol indicates that the power supply is grounded for operation.
Manufacturer
Page 6/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
2.2.3
Symbols on the packaging
Transport upright (up = in direction of arrow)
Protect from impact!
Protect from wet conditions!
Permitted temperature range: -10°C to +40°C
Permitted humidity range: 30% to 85% 800 hPa - 1060 hPa
Permitted air pressure: 800 hPa - 1060 hPa
English – V100 – Last update: 09/2018
Page 7/60
Operating Manual BaehrTec A700
2.3
Foreword
Dear customer! We are delighted that you have chosen to purchase this foot care dry technology device. The BaehrTec A700 has technical features, which will help to enhance your work. The BaehrTec A700 is made from a variety of high-quality aluminium, stainless steel and plastic parts, which are also used in sports car and aircraft construction and therefore, guarantee ultimate stability and quality. The microprocessor-controlled electronics also ensure maximum power and performance from the electronic components. Furthermore, the BaehrTec A700 has an electronic readjustment for the handpiece motor, which provides power and performance even in the lowest speed range. Try it yourself and you will be amazed. Another highlight is the Easy-Speed concept. Thanks to the instrument illustrations on the controller, setting the engine speed for the instrument currently in use is guaranteed to be child’s play (however, this is no substitute for the operator checking that the maximum speed for the instrument currently in use is not exceeded). In addition to the Easy-Speed concept, the BaehrTec A700 has a colour display, which provides you with additional information and which will facilitate adjusting several device settings (e.g. colour background). Modern electronic devices typically have energy-saving features. Therefore, we deliberately excluded a standby mode for the BaehrTec A700. So, when your device is not required, please turn it off using the main switch, which is located in a user-friendly position on the front of the device. Protect the environment and your purse. You have the following powerful advantages with the BaehrTec A700: - very lightweight - very low noise level - easy operation with a high degree of operational safety - high performance, perfectly adjusted to the working conditions - high robustness (for mobile use) - high and long-term reliability - high energy-saving potential (no standby mode) - Button on handpiece The BaehrTec A700 foot care device is manufactured and tested in accordance with strict quality criteria. We hope you enjoy your new device and we wish you every success in operating it. Your Gustav Baehr GmbH
Page 8/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
2.4
General product description and intended use
Rotating instruments (grinder, files, etc.) are actuated with the BaehrTec A700 foot care device. These can be used to strip away dry skin, calluses, nails etc. on feet and hands. The device is intended for the following fields of application: Foot care, cosmetics, wellness, nail design. It can only be used by trained professionals. Other types and fields of application are carried out at your own risk and may pose risks. No type of misuse is permitted. Improper use may lead to damage to persons or objects. The manufacturer cannot be held responsible for damages caused by improper use, unqualified personnel or incorrect operation. All warranty claims are void following improper use or opening the device or the corresponding accessories. WARNING: This device or its accessories cannot be altered without the approval of the manufacturer. The BaehrTec A700 cannot be used for purposes of podiatric or medical treatments. Only use the power cable approved by the manufacturer to operate your device. If you require a new cable, please contact the manufacturer. Operating the device using a different cable is not permitted. 2.4.1
Operator requirements
This device can only be used by trained and instructed podiatrists, cosmeticians, nail designers or persons in related occupational categories. They must be familiar with the corresponding principles of operation and have relevant qualification. The operator is obligated to and must ensure that
• • •
only fault-free and flawless work equipment is used he or she protects himself or herself, the patient and others from risks contamination by the device is avoided
English – V100 – Last update: 09/2018
Page 9/60
Operating Manual BaehrTec A700
2.4.2
• •
• • • • • •
• • •
Employee and Customer Protection It is essential that you read this section with the utmost care! It contains important information on protecting yourself, others and the device from damage! Only use high-quality rotating instruments with a standardized shaft diameter according to DIN EN ISO 1797 amounting to 2.35 mm, cylindrical TYPE 2 from the BAEHR product range. Please observe the specific instructions of rotating instruments when using them. Above all, observe the manufacturer's information on maximum speeds, cleaning, disinfection and sterilization. Please refer to the “Rotating instruments” chapter in the current main catalogue of the Gustav Baehr GmbH for more detailed information regarding the instruments (including their specific function). Disinfect, clean and if required, sterilize the instruments after each use according to the specifications of the respective manufacturer of the instruments. Only use cleaned, disinfected and if necessary, sterilized instruments for each new customer, to avoid a possible transfer of germs to the next customer. Disinfect the handpiece after each use and before each new customer (please make sure that no disinfecting agent or other liquids penetrate the device during the process). Please refer to chapter 5.2 of this operating manual for more detailed information. Disinfect all parts of the device that could have come into contact with contaminated particles after each use and before treating each new customer (please ensure that no disinfecting agent or other liquids penetrate the device during the process). The operating staff must wear protective gloves as well as eye, mouth and nose protection when using the device. When using the device, the employees must make sure that neither hair nor any other loose objects such as wipes, cotton or the like can penetrate the area of the rotating instruments. A hair net must be worn where necessary. Objects, which can be caught in rotating components, cannot be in the area of treatment. The operating staff must bear in mind that the particles that are removed when working with the rotating tools may chip. The device must be maintained and cleaned according to the instructions before and after long pauses in use. The device can only be used with accessories approved for the device. Using unapproved accessories can lead to an increased emission or a minimized resistance to interference or other EMC phenomena. The national statutory provisions must be observed during use, in particular:
the currently applicable work regulations the currently applicable accident prevention measures To guarantee constant readiness for operation and preservation of value, the prescribed care work and maintenance services must be performed. The device can only be repaired using replacement parts approved by the manufacturer and in accordance with the manufacturer’s instructions. The recommended maintenance services (after notification, but at the latest within 24 months) and inspection and repair work can only be performed by the manufacturer. In line with a repair/maintenance work, please conduct or repeat necessary safety tests if applicable. This device cannot not be modified without the manufacturer’s permission. 2.4.3
Possible risks for customers
The suction technology and filter system used in the BaehrTec A700 significantly contribute to a minimization of potentially pathogenic dust in the ambient air and therefore, reduce the risk of communicable germs (microorganisms). Consequently, the customers’ risk based on inhalation is reduced to a minimum and the treatment of immunocompromised customers is justified. Page 10/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
Possible risks of infection can be detected by routinely and diligently determining the medical history and in doing so, be prevented. It is extremely important that you only treat areas of healthy skin or nails with disinfected/sterilized instruments, in the event that you previously conducted work in infected areas. 2.4.3.1
Risks due to dust and removed materials
Due to the effective suction system and the filter system used for the BaehrTec A700, the risk to customers based on inhalation of potentially pathogenic dust is reduced to a minimum. A risk due to removed materials (such as nail residues e.g.) is regarded low based on the sufficient distance to the treatment area. 2.4.3.2
Risk due to moving or rotating parts/instruments
Intense pressure and high rotational speeds can lead to an unwelcome heat development in the area being treated and in the worst case, to damage of the tissue concerned due to heat development. The operator must always be aware that an unintentional puncturing of the skin can occur if he or she is inattentive or the customer makes sudden movements (out of reflex). However, this risk is extremely low in the case of professional handling and constant visual checks. ATTENTION! In any case, puncturing the skin must be avoided! 2.4.3.3
Allergy risks
The customer normally does not come in contact with the surface of the BaehrTec A700 but solely with the rotating instruments. Therefore, there can, at best, be a susceptibility to allergies regarding the components of the rotating instruments. However, since the treatment involves a very short times of contact (under 30 minutes), this is a minimal risk. 2.4.4
Possible risks for operators
2.4.4.1
Risks due to dust and removed materials
The suction technology and filter system used in the BaehrTec A700 significantly contribute to a minimization of potentially pathogenic dust in the ambient air and therefore, reduce the risk of communicable germs (microorganisms). Consequently, the operators’ risk based on inhalation is reduced to a minimum. Always wear personal protective equipment (such as face masks, which cover mouth and nose) when working. A risk due to removed materials (such as nail residues e.g.) is regarded a hazard to the operator based on the close proximity to the treatment area. In order to minimize this risk, the operator must wear eye, mouth and nose protection during treatments. 2.4.4.2
Risk due to moving or rotating parts/instruments
Loose objects such as hair, clothing, jewellery, etc. can get caught and wound up in the rotating parts and instruments. To avoid injuries, the operator must make sure that such loose objects do not come in contact with moving parts / rotating instruments. Hair must be tied back English – V100 – Last update: 09/2018
Page 11/60
Operating Manual BaehrTec A700
if necessary or a hair net must be worn. When choosing his or her work clothes, the operator must make sure that these cannot get caught in the moving parts / the rotating instruments. These measures minimize the risk. To prevent damage to/scratches on the device and for hygienic reasons, rings or other jewellery cannot be worn when operating the device. 2.4.4.3
Allergy risks
A susceptibility to allergies regarding the materials used in the BaehrTec A700 cannot be ruled out but is regarded extremely low however, can be further minimized by wearing disposable gloves. Disposable gloves should also be worn for hygienic reasons during every treatment session. 2.4.5
Safety information
The device is not approved for operation in potentially explosive areas. Before every application, the operator must make sure of the functional safety and proper condition of the device. Improper handling, maintenance and care can lead to premature wear and malfunctions. This can result in a reduced product life. Therefore, clean and maintain the device regularly and appropriately and send the device to be serviced on a regular basis (observe service indicator or at the latest within 24 months)! Damaged functional parts can cause damage or injuries to persons or objects. Furthermore, this may result in (even greater) damage to your device. Stop working immediately and disconnect the device from the mains when functional parts are damaged and contact customer service. If you put the handpiece down, there is risk of injury when reaching for the handpiece. Injuries from used instruments can result in infections. Please take care when setting down the handpiece, so that you do not injure yourself. Keep children away from the device! Risk of strangulation due to the power cable and handpiece hose. Manipulation of the device by children (for use at home) Risk of swallowing small parts/accessories (e.g. instruments) In households, there is the risk of the power cable being damaged by pets for example. Therefore, please check the power cable regularly for damage and if damage is detected, immediately disconnect the device from the mains! Protect the device by checking it regularly and if necessary, clean it to prevent pest infestation! Always follow the instructions for operation and transport! 3
Before using the device for the first time
3.1
Scope of delivery
Before first use, you should check that all items have been delivered. Items delivered: 1 x A700 control unit incl. handpiece (these are firmly connected to each other) Page 12/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
1 x Operating Manual 2 x dust bag for BaerTec A700 (1 bag already installed) Item no. 20701 2 x turbine protection filter (1 filter is already inserted) Dimensions: (~ 93 x 78 mm) 2 x sound-insulating fleece (1 filter is already inserted) Dimensions: (~ 48 x 57.5 mm) 2 x coarse filter fleece (1 filter is already inserted) Dimensions: (~ 48 x 57.5 mm) 2 x ultra-fine filter fleece (1 filter is already inserted) Dimensions: (~ 48 x 57.5 mm) 2 x carbon filter foam (1 filter is already inserted) Dimensions: (~ 48 x 57.5 mm) 1 x power cable with straight cold device plug Item no. 20970006 1 x Easy-Clean tool kit Item no. 40279 1 x damper for handpiece sleeve (set) Art-No.: 40286 For more information, please see the section on "Changing the dampers for the handpiece sleeve". If your delivery is incomplete, please inform us of this immediately. Please keep the delivery box along with any packaging accessories. The packaging was developed for this device and provides the best possible protection during transportation. Therefore, please use the original packaging if you send your device in for servicing. There is no claim to warranty for any damages caused during transportation due to inadequate packaging. 3.2
What to observe before every use! It is essential that you read this section with the utmost care! It contains important information on protecting yourself, others and the device from damage!
The term BaehrTec A700 used in this section refers both to the control unit as well as the handpiece. Before use, please check whether the type of current and the mains voltage of the power source are suitable for the use of this device. Information on the type of current and the mains voltage can be found on the type plate on the control unit. When setting up the device, ensure that it is placed on a level base, that it cannot fall down and that the extracted air can escape easily. Keep the BaehrTec A700 away from children. Do not expose the device to direct heat sources (heaters, intense sunlight, etc.). English – V100 – Last update: 09/2018
Page 13/60
Operating Manual BaehrTec A700
Make sure the power cable is not damaged by being pinched, bent or rubbed on sharp edges. If you notice any damage to the mains cable, please immediately stop working with your device, turn off the main switch and immediately remove the safety plug from the safety socket. To be able to work with the device again, please order a new power cable. Only use manufacturer approved power cables to operate your device. If you require a new cable, please contact the manufacturer. Operating the device using other cables is not permitted. Never operate the device with a damaged power cable. Your device has a detachable connector plug mechanism (see section "rear view") Please ensure that the device is positioned so that a disconnection is unlikely at all times. Do not work with the BaehrTec A700 in damp rooms such as saunas or bathing facilities for example. Wet conditions and moisture on the control unit can lead to dangerous current leaks, which pose the risk of an electric shock. Disconnect the device immediately from the socket. Please send the device in for servicing with a description of the defect. Before each use (including before first time use), please make sure that the dust bag and all other filters have been inserted correctly. Never work with the device unless all filters are inserted correctly. Avoid significant differences in temperature. These can also lead to the formation of moisture (condensation). Protect the BaehrTec A700 from frost. The device must be switched off and disconnected from the mains before carrying out any cleaning/maintenance work. Disconnect the safety plug from the mains immediately if you discover any damage to or malfunctions of the device. The manufacturer does not accept any liability for damages to objects, animals or persons caused by incorrect operation of the BaehrTec A700. Please ensure that the BaehrTec A700 and the instruments are always in a flawless hygienic condition, to avoid putting your own health or that of others at risk. Find more details in section "Care (disinfection)" of the BaehrTec A700. Rings or jewellery worn while working with the device can cause scratches on the handpiece. Such damage is excluded from the warranty. You should never wear jewellery when working with the device. Please only work with the suction turned on in order to suction off any pathogenic dust and to prevent the handpiece motor or the handpiece from becoming warm. Never submerge the device in liquids and do not suck up any liquids. If you suck up any cotton, paper or the like, this can clog the suction openings in the handpiece. This can severely affect the suction power. If the symbol for a filter change appears on the display, it is essential that you change the dust bag (the display can only function reliably if all filters are inserted correctly. Therefore, only work with the device if all filters are inserted). If you do not do so, the device will automatically switch to suction level 3 after approx. half a minute, to prevent any damage to Page 14/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
your device (please refer to the section "Filter change" for more information on how to change the dust bag and the filter). Never work with the device if the dust bag or the filter are not inserted, as in such cases, the device may be damaged and the warranty will expire.
English – V100 – Last update: 09/2018
Page 15/60
Operating Manual BaehrTec A700
Warning – risk of injury! As shown in the illustration, you should avoid "pulling motions" during your work because this can cause the instruments to slip out. Please make sure that you do not exert too much pressure on the instrument (skin burns).
Fig. 2a Wrong
Fig. 2b Right
Page 16/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
Fig. 3a You can hold the handpiece as you would a pen or pencil, to perform precision work in an ergonomic and exact manner.
Fig. 3b You can wrap your fingers around the handpiece, to treat larger surfaces in a relaxed manner. English – V100 – Last update: 09/2018
Page 17/60
Operating Manual BaehrTec A700
4
Device description
4.1
Control unit description
4.1.1
Front view BaehrTec A700
Fig. 4 (1) Control unit housing Main switch: (2) "ON" and (3) "OFF" with corresponding (4) LED (5) – (12) Push buttons for instrument speeds (6,000 – 27,000 rpm) with corresponding LEDs (5a) – (12a) (13) Push button to switch handpiece motor on and off (14) - (15) Push buttons handpiece speed + and - (1,000 rpm) (16) Push button for instrument direction right/left (17) Push button "Home" (18) Push button "Options menu" (19) Colour display (20) Push button for operational readiness of suction (21) Push button suction MIN & (22) Push button suction MAX (27) - (28) Push buttons suction level change + and (29) - (30) Push buttons "Memory"
Page 18/60
English – V100 - Last update: 09/2018
Operating Manual BaehrTec A700
4.1.2
Side view with handpiece holder
Fig. 5 (32) Handpiece holder
English – V100 – Last update: 09/2018
Page 19/60
Operating Manual BaehrTec A700
4.1.3
Side view with dust bag lid (closed)
Fig. 6 (33) Dust bag lid with handle (34) Handpiece outlet (35) Screws for handpiece outlet Can only be unscrewed by the manufacturer (36) Suction hose
Page 20/60
English – V100 - Last update: 09/2018