EasySpray System

EasySpray Instructions for Circulating Nurse Quick Reference Guide April 2012

Quick Reference Guide

2 Pages

EASYSPRAY Pressure Regulator Quick Reference Guide  1  Instructions for Circulating Nurse – EASYSPRAY Device  Connect EASYSPRAY device to IV pole or cart rail using the clamps on the back of the device.  1  3  4  5  Set wall unit pressure between 3.5 and 7 bar (51-100 psi).  Connect the black tube, located at the side of the EASYSPRAY device, to a propellant gas source. Use medical compressed air or nitrogen only.  Connect Spray Set filters to EASYSPRAY device. Connect the blue filter to the blue female Luer connector and the clear filter to the male Luer connector.  Turn the on/off switch on the front side of the EASYSPRAY device to the ON position.  Check the gauge on the EASYSPRAY device for the appropriate pressure range of 1.5-2.0 bars (21.5-28.5 psi). Adjust pressure setting by turning the black pressure control knob.  3  4  5  6  2  Spray Set for TISSEEL [Fibrin Sealant]  Prepare TISSEEL [Fibrin Sealant] according to the instructions in the package insert.  1  2  Instructions for Scrub Nurse –  For Topical Use Only  For Tech Support Call 1-877-TISSEEL  For Topical Use Only  Firmly attach the spray head to the nozzle of the syringes.  For Topical Use Only  Fasten the pull strap to the syringe to assure the spray head is tightly secured.  For Topical Use Only  Fit the connection tube of the spray set to the Luer-lock connector on the underside of the spray head.  6  For Topical Use Only  Attach the clip (on the end of the sensor line) by sliding it into the grooves located on the top of the syringe plunger.  For Topical Use Only  A spraying distance of 10 –15 cm is recommended. In specific situations where spraying at less than 10 cm is necessary, the gas pressure must be reduced appropriately.  Pass the assembled TISSEEL syringe to the surgeon for spray application. Pass the end of the connection tube with the sterile filters to the circulating nurse.  O2 Do Not connect to an oxygen source.  Instructions for Surgeon  2  For Topical Use Only  Do Not use rechargable batteries. TIPS • The EASYSPRAY device will continue to emit gas for a brief period after the thumb is removed from the clip/plunger. This delay helps to avoid clogging of the spray head.  For Topical Use Only  To activate the flow of gas, occlude the opening in the clip center with thumb. To begin application, gently depress the TISSEEL syringe plunger.  Selected Important Risk Information -Air or gas embolism has occurred when using the spray device without fibrin sealant, or fibrin sealant was administered using pressurized gas. This may occur if a spray device is used at higher than recommended pressures and/or in close proximity to the tissue surface. Please see Indications and Important Risk Information and using the spray device without the fibrin sealant on the back. Rx Only: For safe and proper use of these devices, please refer to the appropriate full device Instructions for Use included.
File Type: PDF
File Size: 276 KB
File Name: Baxter - EasySpray Instructions for Circulating Nurse Quick Reference Guide April 2012 - 2012-04.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions