Baxter

EasySpray System

EasySpray Instructions for Circulating Nurse Quick Reference Guide March 2012

Quick Reference Guide

2 Pages

Vials Blue • Sealer protein concentrate • Fibrinolysis inhibitor Black • Calcium chloride • Thrombin  Quick Reference Guide  1  Instructions for Circulating Nurse  Turn on the FIBRINOTHERM device (amber switch) and place all vials in their wells. Allow vials to warm for several minutes (the indicator light goes on and off automatically indicating proper warming temperature). Do not turn on magnetic stirring at this time (green switch).  1  Accessories for DUPLOJECT Preparation (Packet B) Scrub Nurse  • Blue-scaled syringe (1) • Black-scaled syringe (1) • Needles (2)  • Blue-scaled syringe (1) • Black-scaled syringe (1) • Needles (2) • DUPLOJECT syringe holder (1) • Joining piece (2) • Cannula tip (4)  For technical assistance please call 1-877-TISSEEL (1-877-847-7335)  2  3  4  5  6  Attach one needle to the bluescaled syringe and one to the black-scaled syringe.  A. Using the blue-scaled syringe, withdraw the entire volume of fibrinolysis inhibitor. B. Inject this entire volume into the sealer protein concentrate vial.  Turn on the green switch to activate magnetic stirring.  Remove the calcium chloride vials from the FIBRINOTHERM device. A. Using the black-scaled syringe, withdraw the entire volume of calcium chloride. B. Inject this entire volume into the Thrombin vial. C. Mix by swirling briefly, then place the Thrombin vial back into its well in the FIBRINOTHERM device.  Sealer protein (blue vial) is sufficiently reconstituted once there are no visible clumps of the powder. At this time, turn off the green switch on the FIBRINOTHERM device. If not dissolved within 20 minutes discard product.  If using the DUPLOJECT EASY PREP System, please refer to the DUPLOJECT EASY PREP assembly instructions.  Instructions for Scrub Nurse  Attach a needle to the blue-scaled syringe and withdraw all of the solution from the sealer protein concentrate vial.  Accessories for Reconstitution (Packet A) Circulating Nurse  C. Discard empty syringe and needle in sharps container.  2  3  4  Attach a needle to the black-scaled syringe and withdraw all of the solution from the Thrombin vial.  A. Remove air bubbles by striking the side of each syringe one or two times while keeping the tip in an upright position.  IMPORTANT: With the syringe tips in the UP position and the DUPLOJECT applicator oriented towards you, expel all air from the syringes simultaneously to ensure equal volume in both syringes.  B. Pull syringes all the way back and load into DUPLOJECT applicator.  For Topical Use Only  *Please see Important Safety information on the back.  RX Only. For safe and proper use of the device, please refer to the appropriate Instructions for Use. Please see Indications and Important Risk Information on the back.  Give the sterile accessories packet B containing the DUPLOJECT applicator to the scrub nurse.  D. Discard empty syringe and needle in sharps container.  Reconstituted solutions may be kept in the FIBRINOTHERM device, or on the sterile field, for up to 4 hours.  5  6  For Topical Use Only  Attach the joining piece to the syringe hubs and secure by fastening the safety clasp to its corresponding clip on the DUPLOJECT applicator.  For Topical Use Only  Fit a cannula tip onto the joining piece. TISSEEL is now ready for application. Note: The cannula tip must be changed with each new application. Reconstituted solutions may be kept in the FIBRINOTHERM device, or on the sterile field, for up to 4 hours.
File Type: PDF
File Size: 253 KB
File Name: Baxter - EasySpray Instructions for Circulating Nurse Quick Reference Guide March 2012 - 2012-03.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions