Baxter

EasySpray System

EASYSPRAY Pressure Regulator Preparation and Administration Guide Nov 2013

Preparation and Administration Guide

2 Pages

Preparation and administration with EASYSPRAY Pressure Regulator COSEAL is indicated for use in vascular reconstructions to achieve adjunctive hemostasis by mechanically sealing areas of leakage1  Preparati o n i n struc t io n s 1 f o r S c r u b N u r s e (Us e A s ept ic Tec hnique) 1  2  In the sterile field, attach powder syringe to transfer port on syringe housing. Ensure syringe clip on syringe housing is rotated away from free plunger.  5  3  Transfer the liquid into the powder syringe by forcefully depressing the free plunger on the syringe housing. Mix contents back and forth, at least 20 times, until all powder is dissolved. End with entire contents in the syringe housing.  4  Disengage the powder syringe and transfer port together by depressing levers on the side of syringe housing.  7  6  Hold the assembly upright and expel all the air from both syringes.  Holding the syringe tips up, level the plungers and rotate the syringe clip to connect the free plunger.  E A S Y S PRAY Instructions 2 for S c r u b N ur s e  Attach applicator tip. DO NOT PRIME the applicator tip. •P  ass applicator to surgeon for focal application -OR- Continue to Step 7 if surgeon is using EASYSPRAY.  • If surgeon is using EASYSPRAY: Remove the standard plunger clip on the COSEAL unit and obtain the COSEAL clip provided in the EASYSPRAY sprayset packaging.  • Use COSEAL within 2 hours of preparation.  8  9  Attach the EASYSPRAY clip to the back of the syringe plungers. There are two rows of slots on the clip. The first row of slots is for the 4/8 mL kits, and the second row is for the 2 mL kits.  11  10  Obtain spray head from sprayset packaging. Firmly attach the spray head to the hubs of the syringes, ensuring the clips lock on both sides.  • Pass the assembled COSEAL unit to the surgeon for spray application.  Fit the spray tubing of the sprayset onto the Luer-lock connection on the underside of the sprayhead.  • Pass the end of the spray tube with the sterile filters to the circulating nurse.  EASYS PR AY I n stru ct io n s 2 f o r C ir c u la t in g N u rs e 1  2  Insert 9V battery into the EASYSPRAY pressure regulator device. Connect EASYSPRAY device to IV pole or cart rail using the clamps on the back of the device. Do not use rechargable batteries.  5  4  3  Connect the black tube, located at the side of the EASYSPRAY device, to a propellant gas source. Use compressed medical air or O2 nitrogen only.  Set wall unit pressure between 3.5 and 7 bar (51-100 psi).  • Accept the sprayset filters passed from the scrub nurse. Connect sprayset filters to EASYSPRAY device. Connect the clear filter to the male luer connector and the blue filter to the blue female luer connector.  Do not connect to an oxygen source.  6  Instructions for Surgeon • To activate the flow of gas, occlude the opening in the clip center with thumb. To begin application, gently depress the COSEAL plungers. Apply only to dry fields in a thin layer.2  Turn the on/off switch on the front side of the EASYSPRAY to the ON position. The low-battery indicator light will only illuminate when the battery is weak and the gas flow is activated at the same time.  Check the gauge on the EASYSPRAY device for the appropriate pressure range of 1.0-2.0 bars.  • The EASYSPRAY device will continue to emit gas for a brief period after the thumb is removed from the clip/plunger. This delay helps to avoid clogging of the spray head.2  Adjust pressure setting by turning the black pressure control knob.4  • Allow at least 60 seconds after application, and before touching or laying any object on top of the Coseal.1 • Spray from a distance of 10-15 cm for optimum results. For a distance of less than 10 cm, the pressure must be adjusted accordingly. Avoid spraying from a distance of less than 5 cm.2 See table below for adjustment settings.  For Tech Support Call 1-800-423-2090 Please see Warnings and Precautions, Indications and Important Risk Information on the reverse side. Distance  5 cm  10 cm  15 cm  Pressure  1 bar/15 psi  1.5 bar/22 psi  2 bar/29 psi
File Type: PDF
File Size: 313 KB
File Name: Baxter - EASYSPRAY Pressure Regulator Preparation and Administration Guide Nov 2013 - 2013-11.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions