General information
We would advise that Clinical staff and Patients using this Chair are advised of the content of this manual to ensure utilisation all of the functions which are designed to provide full satisfaction and safe usage.
2
Installation If the floor surface is uneven, you can adjust the glide feet to ensure that the Chair is stable. Turn the Glides in a clockwise direction and tighten the locking nuts with a spanner. Fix the front glides first and then adjust the back Glides to suit the floor level.
Glides
The Chair can be ordered with lockable castors (extra charge). The castors can be locked individually in order to guarantee safe positioning.
Locking lever
3
Headrest
The head rest is tiltable, telescopic and removable. To remove the head rest pull it out of its slider. For smaller patients we recommend to swivel the headrest 90° as shown
4
Armrests
The armrest can be lifted upwards and lowered backwards to 180° if required. They stop automatically in three positions: at 90° (vertical) for recommended side entrance onto and off the Chair, at 0° normal positioning when the patient is sitting, at 180° for a comfortable and physically correct position of both arms, when the customer is lying face down on their front. The arm rests move synchronously with the back section of the Chair.
5
Handset control
The functions:
Foot part lifting
Foot part lowering
Hight adjustment upwards
Hight adjustment downwards
Back part lifting
Back part lowering
Half automatic: Back part lowering and foot part lifting: Rückenteil senkt sich und Fußteil hebt sich
Half automatic: Back part lifting and foot part lowering
6
Adjustment of inclination (inclination of seat)
The inclination of the seat is automatically adjusted so that as soon as you adjust the height (Height adjustment upwards) on the hand control the seat reclines and arrives at its maximum after approx. 4 seconds.
7
Adjustment of Extending Legrest
If a patient is sitting in the Chair for extended lengths of time the legrest can be adjusted by the Clinical staff to provide added comfort for the patient. When the Chair has the legrest raised to the horizontal positioning the two knobs underneath the legrest can be loosened which enables the legrest to be extended and then tightened at the appropriate extended length. At the end of the session, the legrest needs to be retracted into the original position by clinical staff and the knobs then need to be tightened before the legrest is lowered or moved in any way.
8
Adjustment of Lumbar support cushion option (optional accessory)
With the red lever in the horizontal position pump the bulb lumbar support adjuster to inflate the lumbar support. Angle the red lever to deflate the lumbar support cushion.
9
Maintenance
The Chair is equipped with maintenance-free polyamide bearings which need no greasing.
10
Cleaning
Clean the Chair with damp cloth and warm rinsing water. Do not use abrasion agents! For cleaning of the upholstery use a soft soapy cloth and clean water rinse. For more stubborn stains use a 5% sodium hypochlorite solution.
11
Precautions
This Chair is designed for a long life-span on the condition that it’s used properly.
If the Chair is in a horizontal position do not sit on the foot part or the back rest as this may cause damage to the construction of the Chair.
12
Trouble-shooting
The Chair does not work:
13
- Plug is not put in the socket - Check power supply to the socket - Plug of handset control underneath the seat is not inserted correctly
Technical Details
Length:
1840 mm
Width including arm rests:
980 mm
Width upholstery of seat:
560 mm
Weight:
approx. 63 kg
Max. load on the seat:
200 kg, 180kg with castors
Electrical connection:
primary
220/240V, 50 Hz
Secondary
24 V DC
Power consumption:
without arm rests: 595 mm
150 VA
For further information or technical advice please contact:
BEAVER HEALTHCARE EQUIPMENT 01732 367777 www.beaverhealthcare.co.uk SOUTHERN OFFICE Beaver Healthcare Equipment Beaver House Unit 1, Paddock Wood Distribution Centre Tonbridge, Kent TN12 6UU 01732 367777 OR NORTHERN OFFICE Beaver Healthcare Equipment Beaver House Station Brae Ellon Aberdeenshire AB41 9DY 01358 725619