BELMONT MEDICAL TECHNOLOGY

CritiCool Systems

CritiCool Infant Step-By-Step Guide Ver 6.3 Rev 001

Step-By-Step Guide

2 Pages

CRITICOOL® Infant Step-By-Step Guide Version 6.3  TARGETED TEMPERATURE MANAGEMENT: CritiCool® Infant Step-by-Step Indication for use: CritiCool is a thermal regulating system, indicated for monitoring and controlling patient temperature  1.  Fill the water tank with sterile water / 0.22 micron filtered water  2.  Place the CritiCool unit at the desired location and lock the front wheels  3.  4.  5.  Power ON the system. After a short Self-Test, a “Select Mode” screen appears. The water inside CritiCool will begin to cool. Select and place the appropriate CureWrap® on the bed or underneath patient (see CureWrap Instructions for Use) • Ensure the CureWra p cla mps a re OPEN • Do not secure the wra p on the pa tient yet!  Connect Core cable to the Core socket on the right and Surface cable to the Surface socket on the left of the system, matching colors, gray to gray and green to green, and then plug the temperature probes into the appropriate adapter cables. Attach the Core and Surface temperature probes to the patient  6. 7.  • Do not pla ce Surfa ce tempera ture probe undernea th the CureWra p • CritiCool ca nnot thermoregula te without a Core rea dout  Connect water hoses to the wrap and to the CritiCool device • Wa ter a utoma tica lly sta rts to flow into the wra p  8.  Return to the touch screen. TTM is the default mode and is already highlighted. Touch OK to select TTM.  9.  The default Set Point (SP) Temperature is 33.5°C. If required, change the Set Point by using the Set Point key:  10.  Wait until the CureWrap is filled with water – When filling is complete, secure the CureWrap to the patient (see CureWrap Instructions for Use)  Thermoregulation with CritiCool has now begun. Note: It is norma l to see slight fluctua tions in the pa tient's tempera ture a s a physiologica l response.  CONTROLLED REWARMING The patient’s temperature is gradually increased every hour by a pre-set step. 1.  Choose Select Mode from the drop-down menu on the upper right side of the screen  2.  Select Controlled Rewarming mode and touch OK to confirm  3. 4.  "Switching to AutoRewarm Mode" message appears • As long a s this messa ge a ppea rs, the Rewa rming ha s not sta rted yet!  Confirm that the Core temperature readout is valid, touch OK and start the rewarming  The patient's temperature will now begin to rise gradually to the required Target Temperature. • The CritiCool rewarming Target Temperature default is 36.5°C • The user can select Target Temperature between 30°C and 40°C using the Target Temperature Key (See user manual instructions) • A Rewarming step (per hour) should be pre-set according to the clinical protocol • CritiCool uses a default Rewarming step of 0.2°C/hour  © Belmont Medical Technologies Part # DDT136009 Rev. 001  Page | 1
File Type: PDF
File Size: 758 KB
File Name: BELMONT MEDICAL TECHNOLOGY - DDT1360009 - CritiCool Infant Step-By-Step Guide Ver 6.3 Rev 001.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions