Getting Started
6 Pages
Preview
Page 1
Getting Started Type 2202
UltraView
Ultrasound Systems
BG0411-B English September 2013
Getting Started with UltraView 2202 • BG0411-B • September 2013
Connect Transducers
2 2
Enter Patient Information
Select Pro Package and Transducer Preset (Diagnostic Setup)
1.
Press [r ID]. Patient window opens.
1.
Press [ c ].
2.
Enter patient data. Use tab key to move from field to field.
3.
Click OK.
2.
Select Pro Package and Diagnostic Setup.
3.
Click Close.
Array transducers To connect: 1. Insert transducer plug into socket (C).
Mechanical socket (A)
2.
Turn locking lever on transducer plug clockwise.
To disconnect: 1. Turn locking lever on plug counterclockwise. 2.
Standby switch (B)
Remove plug from socket.
Array sockets (C)
Turn System On and Off
Mechanical transducers
To turn system on: • Press the green standby switch (B) ONCE. Wait until startup screen disappears. System is ready to use.
To connect: 1. Align red mark on plug with red dot on transducer socket (A).
To turn system off: • Make sure system is completely up and running. Press standby switch (B) ONCE. Caution: Never unplug system from wall while it is running! Turn off system and wait for light on switch to go out before unplugging.
2.
Insert plug in socket.
To disconnect: 1. Pull back on plug locking mechanism (collar). 2.
Remove plug from socket.
Getting Started with UltraView 2202 • BG0411-B • September 2013
3
Getting Started with UltraView 2202 • BG0411-B • September 2013
Frequently Used Keys
22.
Transducer/Application: Press to select Pro Package or Diagnostic Setup.
33.
Gain: Brighter/Darker.
44.
Puncture: Activates puncture lines/brachy matrix.
55.
Simultaneous/Split Screen: Activates simultaneous imaging. Displays 2 screens.
7
Resolution: Increases resolution (decreases scanning frame rate) or vice versa in B-mode or Color mode.
8
Frequency: Changes MHz.
9
Basic Measure: Activates cursors for basic measurement.
10
Depth: Changes maximum depth (distance from transducer). Press + to make objects appear larger, - to make them appear smaller.
11
Save: Stores image on hard drive.
Zoom: Turns on the zoom box. Press again to zoom in. A third press resets the zoom area. A long press turns zoom off if it is on.
12
Select/Click: Press to select option.
Works when image is frozen or not frozen.
13
Print: Sends image to printer.
14
Freeze/Unfreeze the image.
K AR BE
L
M
S S
8
2ESOLUTION
S
S
5SER DEFINED
$YNAMIC 2ANGE
7IDTH
S S
T
S
T
9
T
#ANCEL
-EASURE 5SER DEFINED
5SER DEFINED
7
T
$OPPLER -ODE
#ALCULATION 5SER DEFINED
ID: Opens Patient window to start examination.
EN 3C LIT
NC S
5SER DEFINED
T
S S S S
T
S
T
T
T T T
- -ODE
S
)NVERSE
&OCUS
11.
&REQUENCY $EPTH
10
5SER DEFINED
66.
S
T
!NGLE
(ARMONIC
T
5PDATE
:OOM
#OLOR -ODE
T
$- #URSOR
S
S
S
S
-$OPPLER 'AIN
$ 0OWER -ODE
" -ODE
,A
S
3TEER
S
S
3OUND
S
"O DY
S
)$
6
S
7ALL &ILTER
3P
S
TO
N TIO
0U
LE R
!U
ICA
S
#OLOR 0OWER 'AIN
S
"ASELINE
RE
E TU R
PP $O
PL
P !
#OLOR "OX
3CALE
5
4
" 'AIN#INE
#7
2
ER
UC
SD AN
3 S
4R
1
4
!NGLE /N/FF S
3AVE 5SER DEFINED
11
12 S
3ELECT
12
S
3ELECT
S 13 0RINT
5SER DEFINED
S
&REEZE
14
Getting Started with UltraView 2202 • BG0411-B • September 2013
5
Getting Started with UltraView 2202 • BG0411-B • September 2013
Copy to USB
Copy to CD/DVD
Click View Exam at bottom of screen. Thumbnails of images and other documents in exam appear in image bar.
Images are copied to USB devices immediately. 1.
Insert memory device into USB port.
When you click Copy to CD/DVD, the selected images are NOT copied immediately to a CD or DVD. They are copied to a staging area.
Point at image you want to view.
2.
A magnifying glass icon appears in upper right corner of thumbnail.
Click each image to be copied. Frame around image turns blue.
3.
Click Export and Copy to USB (without Patient ID) or Copy to USB.
View Exam 1.
2.
3.
6
Click magnifying glass. Little frame around it turns blue. Document is displayed in the scan area.
4.
3.
Insert a CD or DVD into DVD drive.
4.
Click Burn CD.
5.
Name (label) CD and click Burn.
To copy: 1. Click each image to be copied. Frame around image turns blue. 2.
Click Export and Copy to CD/DVD (without Patient ID) or Copy to CD/DVD.
Click USB Eject to remove memory device. Getting Started with UltraView 2202 • BG0411-B • September 2013
7
Getting Started with UltraView 2202 • BG0411-B • September 2013
P Shortcut Keys
F Shortcut Keys
P1: h
F1:
P2: t
F2:
P3:
F3:
P4:
F4:
P5:
F5:
P6:
F6:
8
Your Notes
F7: F8: Report F9: F10: Add pointer arrow to image
Getting Started with UltraView 2202 • BG0411-B • September 2013
9
This Book is not a Complete User Guide Before you use the system, you must read the Safety chapter in the 2202 Pro Focus UltraView User Guide. It contains safety information that is important for avoiding injury and for avoiding damage to the equipment. You must also read Care, Cleaning & Safety, which contains information about cleaning and disinfection as well as information about required inspections, calibration and maintenance. The UltraView 2202 Advanced User Guide contains detailed information for the advanced user. www.bkmed.com This guide is also available on the BK Medical website. Please go to the Customer Service section to download user manuals. If you have comments about the user documentation, please write to us at info@ bkmed.dk. We would like to hear from you. © 2013 BK Medical