Directions for Use
4 Pages
Preview
Page 1
SPO2 Accuracy 70 - 100%: Arms < 3.0% 0 - 69%: Unspecified Accuracy test methods available from the manufacturer upon request
Instructions for use: Reusable SoftFlap® (Finger Clip) Pulse Oximetry Sensors DIRECTIONS FOR USE Intended Use: Bluepoint Medical Finger Clip oximetry sensors are indicated for use in continuous non-invasive monitoring of arterial oxygen saturation and pulse rate. They are original or fully compatible replacement sensors intended for use with major brands of pulse oximeters and patient monitors. Select the sensor model number that matches the brand of oximeter or patient monitor that you are using.
LED Specifications LED
Wavelength
Radiant Power (typical)
Brand
Red
660 nm
3.5 mW
All below
Infrared
885 nm
3.5 mW
Nellcor, CSI
890 nm
3.5 mW
HP / Phillips
905 nm
3.5 mW
Datex, BCI, Minolta, Bluepoint Medical
910 nm
3.5 mW
Nonin
935 nm
3.5 mW
Nihon-Kohden
940 nm
3.5 mW
Ohmeda, Novametrix
Precautions: For further instructions, warnings and precautions refer to the operating instructions provided with your oximeter. Do not autoclave or immerse the sensor in liquid. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Warnings: Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor every 8 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to oedematous or fragile tissue. Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Excessive patient motion, excessive ambient light, electromagnetic interference, dysfunctional haemoglobin, low perfusion, intravascular dyes, finger nail polish and long or artificial finger nails may affect the sensor performance and the accuracy of the measurement. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive bio-compatibility testing. Further information is available upon request. Application of the Sensor 1. Connect the sensor cable to the Bluepoint Medical adaptor cable that fits your oximeter or directly to the patient monitor. Then switch on the oximeter and verify proper operation. 2. Insert the patient’s digit into the sensor. The preferred digit to use for adults is the index finger. The digit is correctly inserted when: The tip of the digit touches the rear guide posts. The sensor cable extends along the top of the patient’s hand. 3. Visually monitor the sensor site to ensure the integrity of the skin. 4. Secure the lead with medical tape.
Adult / Paediatric Cleaning the Sensor To clean the sensor between uses or between patients, wipe the sensor surfaces with alcohol. Environmental Requirements Operating temperature range: 10° - 40° C (50° - 104° F) Storage and transportation temperature range 0° - 50° C (32° - 122° F) Relative humidity: 0 - 75% non-condensing
Disposal Follow local regulations governing disposable recycling plans regarding disposal or recycling of device components. A list of component materials is available by contacting Bluepoint Medical. All registered trademarks recognized. Bluepoint Medical Model
Oximeter Brand
Cable Length
SF4001
Nellcor
0.90 m
SF4002
Nellcor
2.00 m
SF4006
HP/Philips
2.95 m
SF4007
HP/Philips
2.00 m
SF4008
HP/Philips
2.95 m
SF4011
Datex
0.90 m
SF4012
Datex
2.95 m
SF4013
GE/Datex
2.95 m
SF4016
Ohmeda
2.95 m
SF4017
Ohmeda
1.00 m
SF4021
BCI
1.20 m
SF4026
Nonin
0.90 m
SF4036
CSI
0.90 m
SF4037
CSI
2.95 m
SF4041
Novametrix
2.95 m
SF4046
Nihon-Kohden
2.95 m
SF4047
Nihon-Kohden
1.60 m
SF6500
Bluepoint Medical
1.20 m
CE0482 Bluepoint Medical GmbH & Co. KG An der Trave 15 23923 Selmsdorf Deutschland/Germany Email: [email protected] Homepage: www.bluepoint-medical.com
Instructions for Use: Reusable SoftFlap® Pulse Oximetry Sensors V2.2 EN/DE/FR/ES