Autoclavable SoftCap Pulse Oximetry Sensors Directions for Use V1.2

Directions for Use

4 Pages

SPO2 Accuracy 70 - 100%: Arms < 3.0% 0 - 69%: Unspecified Accuracy test methods available from the manufacturer upon request LED Specifications  Instructions for use: Autoclavable SoftCap® Pulse Oximetry Sensors DIRECTIONS FOR USE Intended Use: Bluepoint Medical SoftCap® oximetry sensors are indicated for use in continuous non-invasive monitoring of arterial oxygen saturation and pulse rate. They are original or fully compatible replacement sensors intended for use with major brands of pulse oximeters and patient monitors. Select the sensor model number that matches the brand of oximeter or patient monitor that you are using. Precautions: For further instructions, warnings and precautions refer to the operating instructions provided with your oximeter. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Warnings: Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor every 8 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to oedematous or fragile tissue. Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Excessive patient motion, excessive ambient light, electromagnetic interference, dysfunctional haemoglobin, low perfusion, intravascular dyes, finger nail polish and long or artificial finger nails may affect the sensor performance and the accuracy of the measurement. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive bio-compatibility testing. Further information is available upon request. Application of the Sensor 1. Connect the sensor cable to the Bluepoint Medical adaptor cable that fits your oximeter or directly to the patient monitor. Then switch on the oximeter and verify proper operation. 2. Insert the patient’s digit into the sensor. The preferred digit to use for adults is the index finger. The digit is correctly inserted when:  The tip of the digit touches the rear guide posts.  The sensor cable extends along the top of the patient’s hand. 3. Visually monitor the sensor site to ensure the integrity of the skin. 4. Secure the lead with medical tape.  LED  Wavelength  Radiant Power (typical)  Brand  Red  660 nm  3.5 mW  All below  Infrared  885 nm  3.5 mW  Nellcor  890 nm  3.5 mW  HP/Philips  905 nm  3.5 mW  Datex, BCI, Bluepoint Medical  910 nm  3.5 mW  Nonin  935 nm  3.5 mW  Nihon-Kohden  Disposal Follow local regulations governing disposable recycling plans regarding disposal or recycling of device components. A list of component materials is available by contacting Bluepoint Medical. All registered trademarks recognized. Bluepoint Model - Adult  Bluepoint Model - Paediatric  Oximeter Brand  Cable Length  SCA4001  SCPA4001  Nellcor  0.90 m  SCA4002  SCPA4002  Nellcor  2.00 m  SCA4006  SCPA4006  HP/Philips  2.95 m  SCA4007  SCPA4007  HP/Philips  2.00 m  SCA4008  SCPA4008  HP/Philips  2.95 m  SCA4011  SCPA4011  Datex  0.90 m  SCA4012  SCPA4012  Datex  2.95 m  SCA4013  SCPA4013  GE/Datex  2.95 m  SCA4021  SCPA4021  BCI  1.20 m  SCA4026  SCPA4026  Nonin  0.90 m  SCA4046  SCPA4046  Nihon-Kohden  2.95 m  SCA4047  SCPA4047  Nihon-Kohden  1.60 m  SCA6500  SCPA6500  Bluepoint Medical  1.20 m  Other brands and cable lenghts on request. Adult  CE0482 Bluepoint Medical GmbH & Co. KG  Paediatric Cleaning the Sensor To clean the sensor between uses or between patients, wipe the sensor surfaces with alcohol.  An der Trave 15 23923 Selmsdorf Deutschland/Germany Email: info@bluepoint-medical.com Homepage: www.bluepoint-medical.com  Autoclaving the Sensor The sensor can be autoclaved at 134°C / 2bar and thereby effectively sterilized. Environmental Requirements  Operating temperature range: 5° - 40° C (41° -104° F)  Storage and transportation temperature range -20° - 70° C (-4° - 158° F)  Relative humidity: 15 - 95% non-condensing Instructions for Use: Autoclavable SoftCap® Pulse Oximetry Sensors V1.2 EN/DE/FR/ES
File Type: PDF
File Size: 115 KB
File Name: bluepoint MEDICAL - Autoclavable SoftCap Pulse Oximetry Sensors Directions for Use V1.2.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions