bluepoint MEDICAL

Autoclavable SoftWrap Pulse Oximetry Sensors Directions for Use V2.3

Directions for Use

4 Pages

Instructions for use: Reusable SoftWrap® Pulse Oximetry Sensors DIRECTIONS FOR USE ® Intended Use: Bluepoint Medical SoftWrap oximetry sensors are indicated for use in continuous non-invasive monitoring of arterial oxygen saturation and pulse rate. They are original or fully compatible replacement sensors intended for use with major brands of pulse oximeters and patient monitors. Select the sensor model number that matches the brand of oximeter or patient monitor that you are using. Precautions: For further instructions, warnings and precautions refer to the operating instructions provided with your oximeter. Do not autoclave. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Warnings: Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor every 8 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to oedematous or fragile tissue. Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Excessive patient motion, excessive ambient light, electromagnetic interference, dysfunctional haemoglobin, low perfusion, intravascular dyes, finger nail polish and long or artificial finger nails may affect the sensor performance and the accuracy of the measurement. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive bio-compatibility testing. Further information is available upon request. Application of the Sensor 1. Connect the sensor cable to the Bluepoint Medical adaptor cable that fits your oximeter or directly to the patient monitor. Then switch on the oximeter and verify proper operation. 2. Select the sensor site on the patient. The preferred sensor sites are the index finger for adults and paediatrics, the hand for infants and on the foot below the toes for neonates. 3. Apply the sensor on the patient:  Position the emitter and detector directly opposite each other.  Apply the sensor firmly but not too tightly. 4. Secure the sensor using an adhesive or foam wrap. 5. Visually monitor the sensor site to ensure the integrity of the skin. 6. Secure the lead with medical tape.  Adult / Paediatric  Infant  Neonatal  Environmental Requirements  Operating temperature range: 10° - 40° C (50° -104° F)  Storage and transportation temperature range: 0° - 50° C (32° -122° F)  Relative humidity: 0 - 75% non-condensing SPO2 Accuracy 70 - 100%: Arms <3.0% 0 - 69%: Unspecified Accuracy test methods are available from the manufacturer upon request. LED Specifications LED  Wavelength  Radiant Power (typical)  Brand  Red  660 nm  3.5 mW  All below  Infrared  885 nm  3.5 mW  Nellcor, CSI  890 nm  3.5 mW  HP/Philips  905 nm  3.5 mW  Datex, BCI, Bluepoint Medical  910 nm  3.5 mW  Nonin  935 nm  3.5 mW  Nihon-Kohden  940 nm  3.5 mW  Ohmeda, Novametrix  Disposal Follow local regulations governing disposable recycling plans regarding disposal or recycling of device components. A list of component materials is available by contacting Bluepoint Medical. All registered trademarks recognized. Bluepoint Medical Model  Oximeter Brand  Cable Length  W4001  Nellcor  0.90 m  W4002  Nellcor  2.00 m  W4006  HP/Phillips  2.95 m  W4007  HP/Phillips  2.00 m  W4011  Datex  0.90 m  W4012  Datex  2.95 m  W4013  GE/Datex  2.95 m  W4016  Ohmeda  2.95 m  W4017  Ohmeda  1.00 m  W4021  BCI  1.20 m  W4026  Nonin  0.90 m  W4036  CSI  0.90 m  W4037  CSI  2.95 m  W4041  Novametrix  2.95 m  W4046  Nihon-Kohden  2.95 m  W4047  Nihon-Kohden  1.60 m  W6500  Bluepoint Medical  1.20 m  W6501  Bluepoint Medical  0.30 m  CE0482 Bluepoint Medical GmbH & Co. KG  Cleaning the Sensor To clean the sensor between uses or between patients, wipe the sensor surfaces with alcohol.  An der Trave 15 23923 Selmsdorf Deutschland/Germany Email: info@bluepoint-medical.com Homepage: www.bluepoint-medical.com Instructions for Use: Reusable SoftWrap® Pulse Oximetry Sensors V2.3 EN/DE/FR/ES
File Type: PDF
File Size: 83.5 KB
File Name: bluepoint MEDICAL - Autoclavable SoftWrap Pulse Oximetry Sensors Directions for Use V2.3.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions