Reusable Earprobe Pulse Oximetry Sensors Directions for Use V1.4

Directions for Use

4 Pages

Instructions for use: Reusable Earprobe Pulse Oximetry Sensors DIRECTIONS FOR USE  Environmental Requirements  Operating temperature range: 10° - 40° C (50° - 104° F)  Storage and transportation temperature range 0° - 50° C (32° - 122° F)  Relative humidity: 0 - 75% non-condensing SPO2 Accuracy 70 - 100%: Arms < 3.0% 0 - 69%: Unspecified Accuracy test methods available from the manufacturer upon request  Intended Use: Bluepoint Medical pulse oximetry ear sensors are indicated for use in continuous non-invasive monitoring of arterial oxygen saturation and pulse rate. They are original or fully compatible replacement sensors intended for use with major brands of pulse oximeters and patient monitors. Select the sensor model number that matches the brand of oximeter or patient monitor that you are using. Precautions: For further instructions, warnings and precautions refer to the operating instructions provided with your oximeter. Do not autoclave or immerse the sensor in liquid. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Warnings: Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor every 8 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to oedematous or fragile tissue. Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Excessive patient motion, excessive ambient light, electromagnetic interference, dysfunctional haemoglobin, low perfusion or intravascular dyes may affect the sensor performance and the accuracy of the measurement. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive bio-compatibility testing. Further information is available upon request. Application of the Sensor The use of the ear sensor is contraindicated for patients whose ears are pierced at the indicated site. 1. The preferred site is the patient’s ear lobe, securing the sensor using the cable support. Alternatively, position the ear sensor on the ear pinna and secure using medical tape. 2. Wipe the patient’s ear clean with alcohol solution. 3. If applying the sensor to the earlobe, insert the ear sensor cable into the cable support, leaving enough residual cable to connect the sensor to the fleshy portion of the ear lobe. 4. Hook the cable support over the patient’s ear. 5. Clip the sensor to the fleshy portion of the ear lobe, with the light source on the outside of the ear. 6. If applying the sensor to the pinna, clip the sensor to the pinna with the light source on the outside of the ear, and ensure that the cable runs behind the ear and down the side of the patient’s body. 7. Secure the sensor cable using medical tape. 8. Connect the sensor cable into the patient monitor and verify proper operation as described in the instrument’s user manual.  LED Specifications LED  Wavelength  Radiant Power (typical)  Brand  Red  660 nm  3.5 mW  All below  Infrared  885 nm  3.5 mW  Nellcor  890 nm  3.5 mW  HP/Philips  905 nm  3.5 mW  Datex, Bluepoint Medical  935 nm  3.5 mW  Nihon-Kohden  Disposal Follow local regulations governing disposable recycling plans regarding disposal or recycling of device components. A list of component materials is available by contacting Bluepoint Medical. All registered trademarks recognized. Bluepoint Medical Model  Oximeter Brand  Cable Length  EP4001  Nellcor  0.90 m  EP4007  HP/Philips  2.00 m  EP4008  HP/Philips  2.95 m  EP4011  Datex  0.90 m  EP4012  Datex  2.95 m  EP4013  GE/Datex  2.95 m  EP4047  Nihon-Kohden  1.60 m  EP6500  Bluepoint Medical  1.20 m  CE0482 Bluepoint Medical GmbH & Co. KG An der Trave 15 23923 Selmsdorf Deutschland/Germany Email: info@bluepoint-medical.com Homepage: www.bluepoint-medical.com  Sensor attached to the ear lobe  Sensor attached to the pinna  Cleaning the Sensor To clean the sensor between uses or between patients, wipe the sensor surfaces with alcohol. Instructions for Use: Reusable Ear Pulse Oximetry Sensors V1.4 EN/GE/FR/ES
File Type: PDF
File Size: 111 KB
File Name: bluepoint MEDICAL - Reusable Earprobe Pulse Oximetry Sensors Directions for Use V1.4.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions