Reusable SoftCap Pulse Oximetry Sensors Directions for Use V2.3

Directions for Use

4 Pages

SPO2 Accuracy 70 - 100%: Arms < 3.0% 0 - 69%: Unspecified Accuracy test methods available from the manufacturer upon request LED Specifications  Instructions for use: Reusable SoftCap® Pulse Oximetry Sensors DIRECTIONS FOR USE Intended Use: Bluepoint Medical SoftCap® oximetry sensors are indicated for use in continuous non-invasive monitoring of arterial oxygen saturation and pulse rate. They are original or fully compatible replacement sensors intended for use with major brands of pulse oximeters and patient monitors. Select the sensor model number that matches the brand of oximeter or patient monitor that you are using.  LED  Wavelength  Radiant Power (typical)  Brand  Red  660 nm  3.5 mW  All below  Infrared  885 nm  3.5 mW  Nellcor, CSI  890 nm  3.5 mW  HP / Philips  905 nm  3.5 mW  Datex, BCI, Minolta, Bluepoint Medical  910 nm  3.5 mW  Nonin  935 nm  3.5 mW  Nihon-Kohden  940 nm  3.5 mW  Ohmeda, Novametrix  Precautions: For further instructions, warnings and precautions refer to the operating instructions provided with your oximeter. Do not autoclave. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Warnings: Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor every 8 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to oedematous or fragile tissue. Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Excessive patient motion, excessive ambient light, electromagnetic interference, dysfunctional haemoglobin, low perfusion, intravascular dyes, finger nail polish and long or artificial finger nails may affect the sensor performance and the accuracy of the measurement. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive bio-compatibility testing. Further information is available upon request. Application of the Sensor 1. Connect the sensor cable to the Bluepoint Medical adaptor cable that fits your oximeter or directly to the patient monitor. Then switch on the oximeter and verify proper operation. 2. Insert the patient’s digit into the sensor. The preferred digit to use for adults is the index finger. The digit is correctly inserted when:  The tip of the digit touches the rear guide posts.  The sensor cable extends along the top of the patient’s hand. 3. Visually monitor the sensor site to ensure the integrity of the skin. 4. Secure the lead with medical tape.  Adult  Paediatric Cleaning the Sensor To clean the sensor between uses or between patients, wipe the sensor surfaces with alcohol. Environmental Requirements  Operating temperature range: 5° - 40° C (41° -104° F)  Storage and transportation temperature range -20° - 70° C (-4° -158° F)  Relative humidity: 15 - 95% non-condensing  Disposal Follow local regulations governing disposable recycling plans regarding disposal or recycling of device components. A list of component materials is available by contacting Bluepoint Medical. All registered trademarks recognized. Bluepoint Model - Adult  Bluepoint Model - Paediatric  Oximeter Brand  Cable Length  SC4001  SCP4001  Nellcor  0.90 m  SC4002  SCP4002  Nellcor  2.00 m  SC4006  SCP4006  HP/Philips  2.95 m  SC4007  SCP4007  HP/Philips  2.00 m  SC4011  SCP4011  Datex  0.90 m  SC4012  SCP4012  Datex  2.95 m  SC4016  SCP4016  Ohmeda  2.95 m  SC4017  SCP4017  Ohmeda  1.00 m  SC4021  SCP4021  BCI  1.20 m  SC4026  SCP4026  Nonin  0.90 m  SC4031  SCP4031  Minolta  0.33 m  SC4036  SCP4036  CSI  0.90 m  SC4037  SCP4037  CSI  2.95 m  SC4041  SCP4041  Novametrix  2.95 m  SC4046  SCP4046  Nihon-Kohden  2.95 m  SC4047  SCP4047  Nihon-Kohden  1.60 m  SC6500  SCP6500  Bluepoint Medical  1.20 m  SC6501  SCP6501  Bluepoint Medical  0.30 m  CE0482 Bluepoint Medical GmbH & Co. KG An der Trave 15 23923 Selmsdorf Deutschland/Germany Email: info@bluepoint-medical.com Homepage: www.bluepoint-medical.com  Instructions for Use: Reusable SoftCap® Pulse Oximetry Sensors V2.3 ENG/DE/F/ESP
File Type: PDF
File Size: 108 KB
File Name: bluepoint MEDICAL - Reusable SoftCap Pulse Oximetry Sensors Directions for Use V2.3.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions