Page 1
Medical gas cylinder data chart
Oxygen
Integral valve
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet flow connection Valve outlet pressure connection Valve operation Flow-rate (litres/min) Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
CD
HX
ZX
ZH(2)
DF(2)
101-CD 460 230 4 6mm firtree Oxygen Schrader (BS 5682) handwheel Firtree: 1-15/Schrader: 40 520 x 100 2.0 3.5
101-HX 2300 230 4 6mm firtree Oxygen Schrader (BS 5682) handwheel Firtree: 1-15/Schrader: 40 930 x 140 10.0 19.0
101-ZX 3040 300 4 6mm firtree Oxygen Schrader (BS 5682) handwheel Firtree: 1-15/Schrader: 40 930 x 143 10.0 14.0
101-ZH 2400 300 4 6mm firtree Oxygen Schrader (BS 5682) handwheel Firtree: 2-4/Schrader: 40 595 x 175 8.0 14.0
101-DF 1360 137 4 6mm firtree
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet flow connection Valve operation Flow-rate (litres/min) Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
ZA 101-ZA 300 300 4 6mm firtree handwheel 0.1 - 15 366 x 85 1.0 1.55
ZB
ZC(2)
AD(1)
DD(2)
101-ZB 300 300 4 6mm firtree handwheel 1 - 15 390 x 85 1.0 2.7
101-ZC 300 300 4 6mm firtree handwheel 0.1 - 5 390 x 85 1.0 2.7
139-AD 460 230 4 6mm firtree handwheel 8 480 x 100 2.0 4.0
109-DD 460 230 4 6mm firtree handwheel 2-4 520 x 100 2.0 3.5
Oxygen Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg) Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg) *(inc valve)
handwheel 2-4 690 x 175 9.4 12.0
Standard valve AZ
C
D
E
J
298121-AZ 170 137 Pin-index ISO 407 key 290 x 106 1.2 2.5
101-C 170 137 Pin-index ISO 407 key 430 x 89 1.2 2.5
101-D 340 137 Pin-index ISO 407 key 535 x 102 2.3 3.9
101-E 680 137 Pin-index ISO 407 key 865 x 102 4.7 6.5
101-J 6800 137 Pin-index (side spindle) ISO 407 key 1320 x 229 47.2 78.0
PD
AF(2)
F
G
101-PD 300 137 5/8" BSP (F) BS 341 No.3 (Bullnose) key 455 x 100 2.0 5.0
101-F 1360 137 5/8" BSP (F) BS 341 No.3 (Bullnose) key 670 x 175 9.4 12.0
101-F 1360 137 5/8" BSP (F) BS 341 No.3 (Bullnose) key 930 x 140 9.4 17.0
101-G 3400 137 5/8" BSP (F) BS 341 No.3 (Bullnose) key 1320 x 178 23.6 39.0
Key notes: (1) The indicated cylinders are for
specialised applications and availability is restricted. (2) For domiciliary use only.
Nitrous Oxide
Standard valve
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
AZ
C
D
E
F
298122-AZ 450 44 Pin-index ISO 407 key 290 x 106 1.20 3.0
141-C 450 44 Pin-index ISO 407 key 430 x 89 1.20 2.0
141-D 900 44 Pin-index ISO 407 key 535 x 102 2.32 5.0
141-E 1800 44 Pin-index ISO 407 key 865 x 102 4.68 9.0
141-F 141-G 141-J 3600 9000 18000 44 44 44 11/16" x 20 TPI (M) 11/16" x 20 TPI (M) 11/16" x 20 TPI (M) BS 341 No 13 BS 341 No 13 BS 341 No 13 handwheel handwheel handwheel 930 x 140 1320 x 178 1520 x 229 9.43 23.60 47.20 22.0 52.0 105.0
ENTONOX (50% O2/50% N2O) Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet pressure connection Valve operation Flow-rate(litres/min) Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
Helium
CD
HX
211-CD 440 137 4 Entonox Schrader (BS 5682) handwheel Schrader: 40 520 x 100 2.0 3.5
211-HX 2200 137 4 Entonox Schrader (BS 5682) handwheel Schrader: 40 940 x 140 10.0 19.0
HELIOX21 (79% He/21% O2)
F
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet flow connection Valve outlet pressure connection Valve operation Flow-rate(litres/min) Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification
163-F 1200 137 5/8" BSP (F) BS 341 No.3
Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
key 930 x 140 9.43 17.0
Carbon Dioxide
Standard valve
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
C
E
LF
VF
201-C 450 50 Pin-index ISO 407 key 430 x 89 1.20 3.0
201-E 1800 50 Pin-index ISO 407 key 865 x 102 4.68 8.5
201-LF 3600 50
201-VF 3600 50
(Bullnose)
J
ENTONOX (50% O2/50% N2O)
Integral valve
Standard valve
G
Standard valve
Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet connection Valve outlet specification
D
F
G
211-D 500 137 Pin-index ISO 407
211-G 5000 137 Pin-index ISO 407
Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
key 535 x 102 2.32 4.0
211-F 2000 137 Pin-index ISO 407 (side spindle) key 930 x 140 9.43 18.0
Integral valve
HX 173-HX 1780 200 4 6mm firtree Heliox Schrader (BS 5682) handwheel Firtree: 1-15 / Schrader: 40 940 x 140 10.0 15.5
key 1320 x 178 23.60 34.5
Standard valve HL
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Nominal outlet pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
173-HL 8200 200 4 Side outlet ISO 5145 No.26 handwheel 1540 x 230 50.0 85.0
Oxygen/Carbon Dioxide mixture (95% O2/5% CO2)
0.860" x 14 TPI (M) 0.860" x 14 TPI (M)
BS 341 No.8 handwheel 930 x 140 9.43 22.0
BS 341 No.8 handwheel 930 x 140 9.43 22.0
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
F
G
J
131-F 1360 137 5/8" BSP (F) BS 341 No.3
131-G 3400 137 5/8" BSP (F) BS 341 No.3
131-J 6800 137 5/8" BSP (F) BS 341 No.3
(Bullnose)
(Bullnose)
(Bullnose)
key 930 x 140 9.43 17.0
key 1320 x 178 23.6 39.0
key 1520 x 229 47.2 78.0
Air
Standard valve
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification
AZ
E
F
G
J
298123-AZ 160 137 Pin-index ISO 407
191-E 640 137 Pin-index ISO 407
191-F 1280 137 5/8" BSP (F) BS 341 No.3
191-G 3200 137 5/8" BSP (F) BS 341 No.3
191-J 6400 137 Pin-index ISO 407
(Bullnose)
(Bullnose)
(side spindle)
Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
key 290 x 106 1.2 2.5
key 865 x 102 4.7 6.5
key 930 x 140 9.4 17.0
key 1320 x 178 23.6 39.0
key 1520 x 229 47.2 78.0
Special gas mixtures Carbon Dioxide/Oxygen mixtures
Lung Function mixtures Types 1-4 Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
AV Various 1500 150 5/8" BSP (F)
AK Various 6000 150 5/8" BSP (F)
(LH) (Side Outlet)
(LH) (Side Outlet)
BS 341 No.3
BS 341 No.3
(Bullnose)
(Bullnose)
handwheel 680 x 180 10.0 18.0
handwheel 1540 x 230 40.0 59.0
Carbon Dioxide/Air mixture (5% CO2/95% Air) Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
AV 299034-AV-PC 1350 137 5/8" BSP (F)
L 299034-L-PC 6750 137 5/8" BSP (F)
(Side Outlet)
(Side Outlet)
BS 341 No.3
BS 341 No.3
(Bullnose)
(Bullnose)
handwheel 680 x 180 10.0 18.0
handwheel 1540 x 230 50.0 82.0
Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
(5% CO2/95% O2)
(10% CO2/90% O2)
(20% CO2/80% O2)
AV 299031-AV-PC 1460 137 5/8" BSP (F)
L 299031-L-PC 7300 137 5/8" BSP (F)
AV 299032-AV-PC 1460 137 5/8" BSP (F)
AV 299954-AV-PC 1530 137 5/8" BSP (F)
(Side Outlet)
(Side Outlet)
(Side Outlet)
(Side Outlet)
(Side Outlet)
(Side Outlet)
BS 341 No.3
BS 341 No.3
BS 341 No.3
BS 341 No.3
BS 341 No.3
BS 341 No.3
(Bullnose)
(Bullnose)
(Bullnose)
(Bullnose)
(Bullnose)
(Bullnose)
handwheel 680 x 180 10.0 19.0
handwheel 1540 x 230 50.0 85.0
handwheel 680 x 180 10.0 19.0
handwheel 1540 x 230 50.0 86.0
handwheel 680 x 180 10.0 19.0
handwheel 1540 x 230 50.0 87.0
L 299032-L-PC 7300 137 5/8" BSP (F)
Helium/Oxygen/Nitrogen mixture (56% N2/35% O2/9% He) Cylinder code Cylinder order code Nominal contents (litres) Nominal cylinder pressure (bar) Valve outlet connection Valve outlet specification Valve operation Dimensions* L x D (mm) Water capacity (litres) Nominal weight full (kg)
AV 299035-AV-PC 1310 137 5/8" BSP (F)
L 299035-L-PC 6580 137 5/8" BSP (F)
(Side Outlet)
(Side Outlet)
BS 341 No.3
BS 341 No.3
(Bullnose)
(Bullnose)
handwheel 680 x 180 10.0 18.0
handwheel 1540 x 230 50.0 81.0
*(inc valve)
L 299033-L-PC 7650 137 5/8" BSP (F)
Cylinder types
Valve types
Integral valve
Pin-index Side Spindle valve
Handwheel valve
Bullnose valve
Pin-index valve
Pin index valves
Oxygen
Nitrous Oxide
Entonox
Air
Carbon Dioxide
BOC Medical Customer Service Centre, Priestley Road, Worsley, Manchester M28 2UT Tel: 0800 111 333 Fax 0800 111 555 Email: bocmedical-uk@boc.com www.bocmedical.co.uk
Medical
The words BOC, BOC Medical are registered trade marks of The Linde Group of companies in the UK. © Copyright BOC Limited MED/309965/APUK/0109/5M
Handwheel side outlet