CapsoVision

CapsoCamPlus

Capsocam Plus Capsule Cleaning Instructions

1 Page

Capsule Cleaning Instructions  1  /  Prior to downloading data from the used CapsoCam® Plus capsule, it must be cleaned. ENZOL®  1  / 11   lean the capsule using ENZOL® Enzymatic Cleaner or equivalent according to the C / ENZOL® manufacturer’s instructions2.  //  ENZOL®  1 oz. (2 TBSP)  4 Liters (1 gallon)  1  /  Add one ounce (2 tablespoons) of ENZOL® Enzymatic Detergent per gallon of water, ENZOL® or follow manufacturers directions on equivalent brand of detergent.  11    OX  min.  Soak capsule in sufficient solution to submerge completely (at least 5 cc). Organic matter should be removed. A minimum soak OX of one minute is recommended. ™  /  ENZOL® If necessary, manually clean capsule, including dimple on end of the capsule, OX with a soft bristle brush. ™  1  1  Thoroughly rinse capsule to remove detergent. Capsule is now ready for high-level disinfection.  OX  Discard detergent after each use or when visibly soiled. Flush used solution down the drain with water or in accordance with local regulations.  ™  OX  ™  ENZOL®  /  1  Disinfect the capsule using Revital-Ox™ Resert® High Level Disinfectant* or equivalent and rinse / OX thoroughly, according to the manufacturer’sENZOL® instructions3. ENZOL®  ™  ™  /  1 8  ENZOL®  /  min.  OX  1  1  ™  Place pre-cleaned, rinsed and dried capsule in 5 cc of undiluted disinfection solution.  3  1  ENZOL®  ENZOL®  2  /  AlwaysENZOL® handle capsules with gloves.  Soak capsule in sufficient solution to submerge completely (at least OXof 8 minutes 5 cc) for a minimum at ≥ 20˚C (68˚F). ™  OX Rinse the capsule with water.  OX  ™  Discard disinfection solution after each use. Flush used solution with water or in accordance with local regulations.  ™  Dry capsule completely** . * Revital-Ox™ RESERT® High Level Disinfectant has demonstrated disinfection efficacy on the presence of organic soil contamination and microbiological burden during reuse and may be reused for up to 21 days. Please see manufacturer’s instructions for limitations and indications related to reuse.  OX  ™  ** Capsules with remnant moisture may have difficulty downloading data. Therefore, please ensure that the capsule is completely dried before attempting download. Sources: 1 CapsoVision, Inc., “Instructions for Use, CapsoCam Plus”, IFU-2796 US (English). 2 Ethicon US, LLC “Enzol Automatic Detergent: Experience the Power of Fast-Acting Clean”, AD-50255-01-US_D, Promotional Data Sheet, 2014. 3 Steris Corporation, “Steris Revital-OxTM RESERT® High Level Disinfectant Technical Data Sheet”, 330-300-4455 Data Sheet, January 1, 2016. © 2019 CapsoVision, Inc. All rights reserved.  				  PN ADV-3996, Rev B
File Type: PDF
File Size: 454 KB
File Name: CapsoVision - ADV-3996 - Capsocam Plus Capsule Cleaning Instructions - 2019 - Rev B.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions