Carl Zeiss Meditec Inc

IOL Master

IOLMaster 500 Quick Instructions

Quick Instructions

2 Pages

flij~ëíÉê=RMM=J=nìáÅâ=áåëíêìÅíáçåë= WARNING - GENERAL HAZARDS These quick instructions are intended as an overview. Instructions for the safe operation of the instrument are to be found in the user manual.  )  Always perform measurements in the correct sequence! All device measurements must be performed before any undertaking any measurements involving direct contact with the eye.  Checking the calibration  • • •  Always check the calibration daily before carrying out measurements on patients!  •  If the measured values are not within the tolerance range given on the test eye, remove the device from service and contact the Carl Zeiss service department.  Use the test eye (ensure that the test eye is clean). Now carry out the measurements on the test eye. The measuring results from the check of measurement functions are saved under patient name !CHECK,DEVICE!. The test eye is ideally suited to practicing operating the IOLMaster.  Useful button functions <N> key: creates a new patient. <A> key: activates DUAL measurement mode <D> key: activates anterior chamber depth measurement mode  <M> key: switches between automatic and manual measurement <K> key: switches between dual, axis length and keratometer measurement modes ... further short cuts can be found in the user manual.  New patient | <N>  •  A new patient can be entered manually. Enter the patient's name and date of birth, separated by points (.). The year of birth should consist of 4 figures, e.g. 07.03.1965 (7 March 1965).  •  An existing data record can also be selected from the patient list. The ultrasound tab is used for importing and exporting ultrasound and patient data (only with Sonolink option).  •  After entering the data, use the navigation bar or the <Enter> key to change to the Overview mode.  Overview mode | <O>  •  Ask the patient whether she/he can see the fixation lamp. Ask the patient to look straight into the yellow light and blink, then to open his/her eyes as wide as possible.  •  Center the 6 illumination LEDs around the pupil (Fig. 1). A traffic light display serves as a quick and simple method of obtaining the optimum measurement setting. When the optimum measurement position has been reached, the traffic light will change from red to yellow to green.  •  If Automatic is activated, measurement will start automatically using the optimum settings and change to Dual measurement mode.  •  If the automatic measuring function has not been activated, press the joystick button, the <A> button or the <space bar> or click on the Dual icon in the navigation bar to change to Dual measurement mode for axial length and keratometry.  Fig. 1  Automatic dual measurement mode (Twin technology) | <A>  •  The IOLMaster 500 is equipped with the latest twin technology which combines measurement of the axis length and corneal curvature. This is referred to as Dual measurement mode.  •  If Automatic is activated, the measurement will start automatically using the optimum settings and change to Dual measurement mode (the eye is measured and the anterior chamber depth shown as the next step).  •  In some cases it may be necessary to measure the axis length manually. To do this, press the <M> key. The Automatic display will disappear. It is also possible to deactivate automatic measurement on the Settings - Measurement tab.  Keratometer (corneal curvature) measurement  •  Cyclic change of the measurement modes Dual, Axial length measurement and Keratometer measurement is possible by clicking on the <K> key if Automatic is deactivated. Select Keratometer measurement mode.  •  Focus the eye so that all six peripheral measurement points are shown sharply in the display. Trigger the measurement by pressing the button on the joystick.  •  Three consecutive measurements of the corneal curvature are taken automatically. Keratometer measurements may be repeated as often as desired; however, only the mean value of the last three measurements will be displayed.  •  If a measurement point is not correctly identified, a blue flashing dot will appear. A further measurement should be taken as a precaution. (Fig. 2).  •  Fig. 2 If the system detects any measurement errors (e.g. deviations within the last three measurements), "Evaluation" appears in the display. In this case, check the tear film of the eye being examined and repeat the measurements until the results are within the tolerances.
File Type: PDF
File Size: 260 KB
File Name: Carl Zeiss Meditec Inc - IOLMaster 500 Quick Instructions.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions