Carl Zeiss
LUMERARESCAN SW MATIRIX June 2014
Matirix Guide
1 Page
Preview
Page 1
10. Juni 2014
LUMERARESCAN_SW_MARTRIX_2014-06-10.DOCX
Build
1.0 1.1 1.2
1.3
46410 50958 54462 (market introduction) 58550 (Bugfix) 61332
1.9 2.0
NET DCU
User Profiles
AUX
Networking Addresses Default / New Installation
IDIS
SW
LUMERA 700
Only for Lumera 700 6634101596 and higher
11.0
NO
Switch
2.7
11.0
NO
Switch
2.7
11.0
NO
Switch
2.7
58799 71963
11.0
YES
Switch
DHCP
2.5
91142
11.0
YES
2.5
100018
11.0 or 11.2
YES
Momentary Contact Switch Momentary Contact Switch
3.0 3.1 3.1
1.2
LUMERA 700 RESCAN 700 - SW Variants SW Build NET DCU User Profiles 3.0 91142 11.0 YES
CALLISTO eye
Video SD 3Chip
Video HD 3Chip
Video HD 1Chip
Video Recording SD )*3
Video Recording HD )*3
Slit Illum.
Assistant
LED Illum. )*6
OHD On X/Y Coupl.
Remark
not supported not supported
NO
NEW / UC
NEW / UC
NO
NEW / UC SW 1.1
NO
NEW
NEW
NO
UC
NO
NEW / UC
NEW / UC
NO
NO
NEW
NEW
NO
UC
NO
NEW / UC
NEW / UC
NO
NEW / UC SW 1.1 NEW / UC SW 1.1
NO
NEW
NEW
NO
UC
)*4
DHCP
NEW / UC
NEW / UC
NEW / UC
NO
NEW
not supported )*1; )*4
NEW / UC
NEW / UC
NEW / UC
NO
NEW
NEW
NEW / UC NEW / UC
NEW / UC
DHCP
NEW / UC SW 1.0 NEW / UC SW 1.1
NEW
DHCP
NEW / UC SW 1.1 NEW / UC SW 1.1
NEW / UC
)*7
3.5
Static IP 192.168.99.10 SN 255.255.255.0
Static IP 192.168.99.20 SN 255.255.255.0
NEW / UC
NEW / UC
NEW / UC
NEW
NEW / UC SW 1.1
NEW / UC SW 1.1
NEW
NEW
NEW / UC
NEW / UC
AUX
SW
LUMERA 700
CALLISTO eye
Momentary Contact Switch
3.2
DHCP
Static IP 192.168.170.1 SN 255.255.255.0
INT with shutter
NO
INT
NO
NO
NO
NO
INT
INT
NEW
CALLISTO eye SW 2.7 no longer supported
Legend: NO = not possible NEW = Option only at new order (no UC Kit) UC = UC Kit (upgrade later in the field) INT = Integrated (always, standard) Future = NOT released / available yet Remarks: 1) CALLISTO eye SW 3.0 by CAR updated to SW 3.1 – SW 3.0 shouldn´t be any more out in the field LUMERA 700 SW 2.0 (new and workflow orientated: USER Profiles / Resight settings, by upgrade to SW 2.0 all user specific settings will be lost) 2) Special SW 3.0 written for LUMERA 700 with RESCAN 700 – SW expects a RESCAN 700. Do not install on a regular LUMERA 700 3) Pay attention on upgrading or replacing integrated video recording. Firmware of video recording might be updated to fit to LUMERA 700 SW 4) From CALLISTO eye 2.x to CALLISTO eye 3.x there was a hardware change of CALLISTO eye as well. CALLISTO eye 2.x is NOT upgradeable 5) Standard is always Dual Illumination: LED-Xenon or LED-LED. No Halogen Illumination in KMAT 6) Illumination Halogen / Xenon not mentioned 7) Momentary contact switch for AUX: Relay switch active only for the time the AUX button is pressed. After released AUX button, the relay will return to its
)*2; )*5
SW Timeline
SW
CALLISTO eye
SW Timeline
LUMERA 700 - SW Variants