Carl Zeiss
OPMI VISU 160 on S8, S81, S88 Suspension Systems Instructions for use Issue 5.0 Oct 2006
Instructions for Use
234 Pages
Preview
Page 1
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Instructions for use G-30-1529-en Issue 5.0 Printed on 09. 10. 2006
2
Key to symbols Different symbols used in this manual draw your attention to safety aspects and useful tips. These symbols are explained in the following.
Warning! The warning triangle indicates potential sources of danger which may constitute a risk of injury for the user or a health hazard.
Caution: The square indicates situations which may lead to malfunction, defects, collision or damage of the instrument.
Note: The hand provides hints on the use of the instrument or other tips for the user.
OPMI® is a registered trademark of Carl Zeiss Surgical GmbH. Invertertube™ is a trademark of Carl Zeiss Surgical GmbH. Superlux® is a registered trademark of Carl Zeiss Surgical GmbH.
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
3
Contents –
Key to symbols
2
Functions at a glance
7
–
VISU 160 surgical microscope
8
–
Illumination systems
9
–
S88 floor stand
12
–
S8 ceiling mount
14
–
S81 ceiling mount
16
Safety
19
–
Notes on installation and use
21
–
When using a wide-angle observation system (e.g. BIOM 3)
27
–
Phototoxic retinal injury in eye surgery
27
–
Safety devices of the suspension systems
32
–
Warning labels and notes
42
Description
49
VISU 160 surgical microscope
52
–
Intended use
52
–
Description of the modules
52
–
Illumination system
57
–
Controls, displays, connections
60
–
Binocular tubes and eyepieces
66
Illumination systems
72
–
Halogen illumination system
74
–
Superlux Eye illumination system
78
– Superlux Eye illumination system with additional integrated halogen illumination (option)
82
Identical modules of the suspension systems
88
–
Suspension arm
88
–
Display field with control keys
90
S88 floor stand
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
92
Issue 5.0 Printed on 09. 10. 2006
4
G-30-1529-en
–
Intended use
92
–
Description of the modules
93
–
Design
94
–
Stand base with column
96
–
Connection panel
98
–
Instrument tray (option)
100
S8 ceiling mount
102
–
Intended use
102
–
Description of the modules
103
–
Design
104
–
Power switch with connector (option)
106
S81 ceiling mount
108
–
Intended use
108
–
Description of the modules
109
–
Design
110
–
Power switch, connector and socket (option)
112
VISU 160 surgical microscope on S88 floor stand
114
–
Intended use
114
–
Design
114
VISU 160 surgical microscope on S8 ceiling mount
116
–
Intended use
116
–
Design
116
VISU 160 surgical microscope on S81 ceiling mount
118
–
Intended use
118
–
Design
118
Foot control panel (option)
120
–
Intended use
120
–
Design
120
Preparations
123
Attaching the equipment
124
–
Mounting the surgical microscope
124
–
Mounting the tube, the eyepieces and the objective lens
128
–
Changing the microscope accessories
130
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
5
G-30-1529-en
Connections
132
–
Connecting the surgical microscope
132
–
Connecting the S light guide
132
–
Strain relief device on S88 floor stand
134
–
Connecting the S88 floor stand
136
–
Relocating the system
138
Adjusting the supension system
140
–
Adjusting the balance setting of the suspension arm
140
–
Adjusting the limit of downward movement
142
–
Positioning the S8 ceiling mount
144
Settings on the control and display panel
146
–
146
Adjusting the suspension system
Adjusting the surgical microscope
147
–
Adjusting the tilt angle
148
–
Adjusting the microscope tilt to angles greater than 15°
149
Operation
151
Checklist
152
–
155
When using a wide-angle observation system (e.g. BIOM 3)
Positioning the S88 floor stand
156
Using the display and key field
158
–
General functions
158
–
Operating the OPMI® on the suspension system
162
Procedure
174
What to do in an emergency
176
–
Failure of the halogen lamp
176
–
Lamp failure in Superlux Eye illumination system
178
–
Failure of lamp control
180
–
Failure of focusing system
180
–
Failure of magnetic brakes
182
–
Failure of the X-Y coupling
182
–
Failure of the zoom function
183
Maintenance / Further information
185
–
186
Trouble-shooting
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
6
–
Changing the halogen lamp
194
–
Changing the Superlux Eye xenon lamp module
198
–
Magnifications / Fields of view
200
–
Care of the unit
201
–
Sterilization
202
–
Disinfecting the control keys
203
–
Ordering data
204
–
Spare parts
206
–
Accessories
208
–
Disposal
209
Technical data
211
–
Technical data
212
–
Ambient requirements
226
–
CE conformity
226
–
Changes to the system
226
Index
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
227
Issue 5.0 Printed on 09. 10. 2006
7
Functions at a glance
Functions at a glance
G-30-1529-en
VISU 160 surgical microscope
8
Illumination systems
9
S88 floor stand
12
S8 ceiling mount
14
S81 ceiling mount
16
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
8
Functions at a glance
VISU 160 surgical microscope 1 2 3 4 5 6 7 8 9 10 11 12 13
Resetting the X-Y coupling and focus to their initial positions Tilting the surgical microscope Adjusting the eyecups Setting your prescription Handgrip Display of the magnification factor of the zoom system DeepView button Selecting light stops Setting the 6° illumination Arrows indicating the focusing range Adjusting the interpupillary distance Manual zoom adjustment Connecting the light guide
7
8 9
page 52 page 148 page 70 page 70 page 62 page 62 page 64 page 64 page 64 page 60 page 66 page 183 page 132
1 2
3 4
5 6 5
G-30-1529-en
2
10
11
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
12
13
Issue 5.0 Printed on 09. 10. 2006
9
Functions at a glance
Illumination systems
2 3 4
Halogen illumination system Closed flap: main lamp is on Open flap: backup lamp is on Selecting a filter Opening the lamp module Manual activation of the backup lamp
page 36 page 36 page 36
5 6 7 8
Superlux Eye illumination system Selecting a filter Manual activation of the backup lamp Opening the lamp module Red segment is lit - backup lamp is in use
page 78 page 78 page 78 page 78
1
1
G-30-1529-en
2
3 4
5 6
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
page 36
7
8
Issue 5.0 Printed on 09. 10. 2006
10
Functions at a glance
1 2 3 4
5 6 7 8
Superlux Eye illumination system with additional integrated halogen illumination (option) Selecting the filter for Superlux Eye illumination Manual activation of the Superlux Eye backup lamp Opening the Superlux Eye lamp module Additional integrated halogen illumination: - Closed flap: main lamp is on - Open flap: backup lamp is on Selecting the filter for additional integrated halogen illumination Opening the lamp module of additional integrated halogen illumination Manual activation of the halogen backup lamp Superlux Eye illumination: Red segment is lit - backup lamp is in use
1
G-30-1529-en
2 3 4 5
6
7
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
page 82 page 82 page 74 page 84
page 84 page 84 page 84 page 84
8
Issue 5.0 Printed on 09. 10. 2006
11
Functions at a glance
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
12
Functions at a glance
S88 floor stand 1 2 3
Control panel page 158 Illumination system page 72 Releasing the magnetic brakes of the suspension page 88 system 4 Limiting the suspension arm's downward movement page 142 5 Removing/mounting the coupling for the page 88 surgical microscope 6 Balancing the suspension arm page 140 7 Locking the stand in position page 96 8 Locking the suspension arm in its horizontal position page 88 9 Connecting the foot control panel or hand switch, page 98 connecting the remote control connector 10 Rated voltage display page 98 11 Connector panel page 98 12 Switching on the suspension system page 98
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
13
Functions at a glance
1
2
7
G-30-1529-en
3
4
4
5
6
8 9 10, 11, 12
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
14
Functions at a glance
S8 ceiling mount 1 2
Locking the suspension arm in its horizontal position page 88 Releasing the magnetic brakes of the suspension page 88 system 3 Balancing the suspension arm page 140 4 Illumination system page 72 5 Control panel (rotatable through 180° or 70°) page 158 6 Connecting the foot control panel or hand switch, page 106 connecting the remote control connector 7 Switching on the suspension system page 106 8 Releasing - moving - locking the lift arm page 104 9 Removing/mounting the coupling for the page 88 surgical microscope 10 Limiting the suspension arm's downward movement page 142
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
15
Functions at a glance
2
1
7
G-30-1529-en
3
8
4
2
5
9
6
10
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
16
Functions at a glance
S81 ceiling mount 1 2
Locking the suspension arm in its horizontal position page 88 Releasing the magnetic brakes of the suspension page 88 system 3 Balancing the suspension arm page 140 4 Illumination system page 72 5 Control panel (rotatable through 180° or 70°) page 158 6 Option: hand control panel socket for ceiling track mount page 112 7 Connecting the remote control connector page 112 8 Connecting the foot control panel or hand switch page 112 9 Switching on the suspension system page 112 10 Removing/mounting the coupling for the page 88 surgical microscope 11 Limiting the suspension arm's downward movement page 142
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
17
Functions at a glance
1
2
3
4
9
G-30-1529-en
2
5
10
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
6
7
8
11
Issue 5.0 Printed on 09. 10. 2006
18
Functions at a glance
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
Safety
19
Notes on installation and use
21
When using a wide-angle observation system (e.g. BIOM 3)
27
Phototoxic retinal injury in eye surgery
27
Safety devices of the suspension systems
32
Warning labels and notes
42
Safety
G-30-1529-en
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006
20
Safety
The device described in this manual has been designed and tested in accordance with Carl Zeiss safety standards as well as German and international standards. This guarantees a high degree of instrument safety. The system described in this user manual has been designed in compliance with the requirements of: –
EN
–
IEC
–
UL
– CSA
In accordance with Directive 93/42/EEC for medical devices, the complete quality management system of the company Carl Zeiss Surgical GmbH, 73446 Oberkochen, Germany, has been certified by DQS Deutsche Gesellschaft zur Zertifizierung von Managementsystemen mbH, a notified body, under registration number 250758 MP23. –
As per Directive 93/42/EEC, the unit is a Class I instrument.
–
For USA: FDA classification Class I.
We would like to provide you with information about safety aspects which must be observed when handling this device. This chapter contains a summary of the most important information concerning matters relevant to instrument safety. Important safety information has been incorporated in this manual and is marked with a warning triangle accordingly. Please give this information your special attention. The correct use of the system is absolutely vital for safe operation. Please make yourself totally familiar with the contents of this manual prior to startup of the instrument. Please also observe the user manuals of any additional equipment. Further information is available from our service department or from authorized representatives.
G-30-1529-en
•
Please observe all applicable accident prevention regulations.
•
The instrument must be connected to a special emergency backup line supply in accordance with the regulations or directives which apply in your country.
OPMI® VISU 160 on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 09. 10. 2006