Carl Zeiss

OPMI TIVATO Microscopes and Fluorescence Devices

TIVATO 700 Release Notes for sw release Ver 1.6

Release Notes

4 Pages

Release Notes for ZEISS TIVATO® 700 Version 1.6 Please read the release notes before the installation of ZEISS TIVATO® 700. The following instructions only apply for the operation of ZEISS TIVATO® 700 Version 1.6.  Topic  Description  Action / Workaround  System Start  The device may display a “KINEMATICS” error message for after power on.    Do not use handgrip and not manually reposition the device during the startup phase. Wait until user selection dialogue before interacting with the device.  The device may have only limited function after restarting.    Ensure waiting at least 10 seconds between switching off and starting of the device.  The device is only fully functional in the specified operating temperature (10°C/50°F – 40°C/104°F) range. After transportation in cold environment the device may require some time to acclimatize.    In case the temperature is outside of the operating temperature range, please wait until the temperature has reached the operating temperature range before starting the device. Please consider the time it takes for the device to get into the operating temperature range when planning demos and presentations. Restart the device to restore normal behavior.   Balancing  The device is not balanced after completing the balancing workflow.    Restart the balancing workflow and closely follow the instructions on the screen. Especially ensure the individual axis calibration by holding the device in the balancing range and tapping the joystick button for multiple times until the microscope is precisely balanced in the pre-defined balancing positions. The axis is precisely balanced when the microscope would not move with open brakes. The microscope is only balanced after the balancing has been fully completed.  XY Movement  Under certain conditions the XY movement may be temporarily inactive.    Press AB brake button on handgrip to re-enable the XY movement function.  Light  No automatic lamp exchange is performed when the active lamp is detected as defective on start up.    Exchanged the lamp manually by using the GUI or physically in the lamp container.  RN-30-9066-en Version 3.0  Page 1
File Type: PDF
File Size: 107 KB
File Name: Carl Zeiss - RN-30-9066-en Ver 3.0 - TIVATO 700 Release Notes for sw release Ver 1.6.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions