Carl Zeiss
OPMI VARIO Microscopes
OPMI VARIO on S8-S81-S88 Suspension Systems Instructions for use Issue 5.0 Jan 2009
Instructions for Use
264 Pages
Preview
Page 1
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Instructions for use G-30-1607-en Issue 5.0 Printed on 30. 01. 2009
2
Key to symbols Different symbols used in this manual draw your attention to safety aspects and useful tips. These symbols are explained in the following.
Warning! The warning triangle indicates potential sources of danger which may constitute a risk of injury for the user or a health hazard.
Caution: The square indicates situations which may lead to malfunction, defects, collision or damage of the instrument.
Note: The hand provides hints on the use of the instrument or other tips for the user.
OPMI® is a registered trademark of Carl Zeiss Surgical GmbH.
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
3
Contents –
G-30-1607-en
Key to symbols
2
Functions at a glance
7
–
OPMI® VARIO
8
–
S88 floor stand
10
–
S88 floor stand with lifting column
12
–
S8 ceiling mount
14
–
S81 ceiling mount
16
Safety
19
–
Notes on installation and use
21
–
Safety devices of the suspension systems
28
–
Warning labels and notes
38
Description
47
OPMI® VARIO surgical microscope
50
–
Intended use
50
–
Special properties
51
–
Design
52
–
Controls, displays, connections
54
–
Binocular tubes and eyepieces
62
Xenon illumination system
66
Identical modules of the suspension systems
72
–
Suspension arm
72
–
Display field with control keys
74
S88 floor stand
76
–
Intended use
76
–
Description of the modules
77
–
Design
78
–
Stand base with column
80
–
Connection panel
82
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
4
G-30-1607-en
–
Instrument tray (option)
84
–
Video monitor (option)
86
S88 floor stand with lifting column
94
–
Intended use
94
–
Description of the modules
95
–
Design
96
–
Stand base with lifting column
98
–
Connector panel
100
S8 ceiling mount
102
–
Intended use
102
–
Description of the modules
103
–
Design
104
–
Power switch with connector (option)
106
S81 ceiling mount
108
–
Intended use
108
–
Description of the modules
109
–
Design
110
–
Power switch, connector and socket (option)
112
VARIO surgical microscope on S88 floor stand
114
–
Intended use
114
–
Design
114
VARIO surgical microscope on S88 floor stand with lifting column
116
–
Intended use
116
–
Design
116
VARIO surgical microscope on S8 ceiling mount
118
–
Intended use
118
–
Design
118
VARIO surgical microscope on S81 ceiling mount
120
–
Intended use
120
–
Design
120
Foot control panel (option)
122
–
Intended use
122
–
Design
122
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
5
G-30-1607-en
–
Foot control panel with 14 functions
124
–
Foot control panel with 8 functions
125
Preparations
127
Attaching the equipment
128
–
Mounting the surgical microscope
128
–
Attaching accessories
130
–
Mounting the tube and eyepieces
132
Connections
134
–
Connecting the surgical microscope
134
–
Mounting the light guide
134
–
Aligning the X-Y coupling
138
–
Strain relief device on S88 floor stand
140
–
Connecting the S88 floor stand
142
Adjusting the supension system
144
– S88 floor stand with lifting column Setting the ergonomic working height
144
–
Adjusting the balance setting of the suspension arm
146
–
Adjusting the limit of downward movement
148
–
Positioning the S8 ceiling mount
150
Settings on the control and display panel
153
–
153
Adjusting the suspension system
Balancing the surgical microscope
154
Adjusting the surgical microscope
156
Surgical microscope with a laser micromanipulator
157
Relocating the system
160
Operation
163
Checklist
164
Positioning the S88 floor stand
168
Using the display and key field
170
–
170
General functions
– OPMI Vario on the suspension system, user interface with SpeedFokus option
174
Procedure
194
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
6
What to do in an emergency
196
–
Failure of a xenon lamp
196
–
Failure of lamp control
200
–
Failure of the zoom function
201
–
Failure of the focusing function
202
–
Failure of magnetic brakes
203
Maintenance / Further information
205
–
Trouble-shooting
206
–
Changing the xenon lamp module
214
–
Adjusting the monitor arm
218
–
Magnifications / Fields of view
220
–
Care of the unit
222
–
Sterilization
223
–
Disinfecting the control keys
224
–
Ordering data
226
–
Spare parts
230
–
Accessories
231
–
Disposal
233
Technical data
235
–
Technical data of OPMI VARIO
237
–
Technical data of S88 floor stand
238
–
Technical data of S88 floor stand with lifting column
240
–
Technical data of S8 ceiling mount
246
–
Technical data of S81 ceiling mount
250
–
Ambient requirements
253
–
CE conformity
253
–
Changes to the system
253
Index
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
255
Issue 5.0 Printed on 30. 01. 2009
7
Functions at a glance
Functions at a glance
G-30-1607-en
OPMI® VARIO
8
S88 floor stand
10
S88 floor stand with lifting column
12
S8 ceiling mount
14
S81 ceiling mount
16
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
8
Functions at a glance
® OPMI VARIO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
G-30-1607-en
Adjusting the eyecup and the prescription Adjusting the interpupillary distance Adjusting the friction of vertical adjustment Recentering the X-Y coupling Adjusting the friction of the OPMI® axis of rotation Manual zoom setting Manual focusing Manual setting of the illuminated field diameter Connecting the light guide Balance setting of the microscope's front-to-back tilt Balance setting of the microscope's lateral tilt Motorized focusing Motorized zoom setting Display of the magnification factor of the zoom system Releasing the magnetic brakes Programmable release buttons Switching off the electrical drive of the focusing system Connecting the mouth switch
OPMI® VARIO on S8, S81 & S88 Suspension Systems
page 64 page 62 page 54 page 60 page 60 page 56 page 56 page 56 page 134 page 54 page 54 page 58 page 58 page 54 page 58 page 58 page 56 page 54
Issue 5.0 Printed on 30. 01. 2009
9
Functions at a glance
2
1
6
G-30-1607-en
3
7
8
4
9
10
11 12
13
OPMI® VARIO on S8, S81 & S88 Suspension Systems
14
5
15 16 17 18
Issue 5.0 Printed on 30. 01. 2009
10
Functions at a glance
S88 floor stand 1 2 3
Control panel page 70 Illumination system page 66 Releasing the magnetic brakes of the suspension page 72 system 4 Limiting the suspension arm's downward movement page 72 5 Removing/mounting the coupling for the page 72 surgical microscope 6 Balance setting page 72 7 Locking the stand in position page 80 8 Locking the suspension arm in its horizontal position page 72 9 Connecting the foot control panel or hand switch, page 82 plugging in the remote control connector 10 Rated voltage display page 82 11 Connector panel page 82 12 Switching on the suspension system page 82
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
11
Functions at a glance
1
2
7
G-30-1607-en
3
4
4
5
6
8 9 10, 11, 12
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
12
Functions at a glance
S88 floor stand with lifting column
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Xenon illumination system Selecting a filter Manual activation of backup bulb Resetting the counter Opening the lamp module Red segment is lit - backup bulb is in use
Control panel Lamp housing of xenon illumination system page 66 Unlocking the magnetic brakes of the suspension page 72 system Limiting the suspension arm's downward movement Removing/mounting the coupling for the page 72 surgical microscope Balance setting Locking the stand in position page 80 Raising/lowering the lifting column page 144 Locking the suspension arm in its horizontal position page 72 Connecting the foot control panel or hand switch, page 82 Connecting the remote control connector Rated voltage display page 82 Connector panel page 82 Turning on the suspension system page 82
1
G-30-1607-en
page 68 page 66 page 68 page 68 page 66
2
3
4
5
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
13
Functions at a glance
6
7
12
G-30-1607-en
8
13
9
9
10
11
14 15 16, 17, 18
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
14
Functions at a glance
S8 ceiling mount 1 2 3 4 5 6
Locking the suspension arm in its horizontal position page 72 Releasing the magnetic brakes of the suspension system page 72 Balance setting page 72 Illumination system page 66 Control panel (rotatable through 180° or 70°) page 70 Connecting the foot control panel or hand switch, page 106 plugging in the remote control connector 7 Switching on the suspension system page 106 8 Releasing - moving - locking the lift arm page 104 9 Removing/mounting the coupling for the page 72 surgical microscope 10 Setting the limit of downward travel page 72
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
15
Functions at a glance
2
1
7
G-30-1607-en
3
8
4
2
5
9
6
10
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
16
Functions at a glance
S81 ceiling mount 1 2 3 4 5 6 7 8 9 10
Locking the suspension arm in its horizontal position page 72 Releasing the magnetic brakes of the suspension system page 72 Balance setting page 72 Illumination system page 66 Control panel (rotatable through 180° or 70°) page 70 Option: hand control panel socket for ceiling track mount page 112 Plugging in the remote control connector page 112 Connecting the foot control panel or hand switch page 112 Switching on the suspension system page 112 Removing/mounting the coupling for the page 72 surgical microscope 11 Setting the limit of downward travel page 72
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
17
Functions at a glance
1
2
3
4
9
G-30-1607-en
2
5
10
OPMI® VARIO on S8, S81 & S88 Suspension Systems
6
7
8
11
Issue 5.0 Printed on 30. 01. 2009
18
Functions at a glance
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
Safety
19
Notes on installation and use
21
Safety devices of the suspension systems
28
Warning labels and notes
38
Safety
G-30-1607-en
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009
20
Safety
The device described in this manual has been designed and tested in accordance with Carl Zeiss safety standards as well as German and international standards. This guarantees a high degree of instrument safety. The system described in this user manual has been designed in compliance with the requirements of: –
EN
–
IEC
–
UL
– CSA
In accordance with Directive 93/42/EEC for medical devices, the complete quality management system of the company Carl Zeiss Surgical GmbH, 73446 Oberkochen, Germany, has been certified by DQS Deutsche Gesellschaft zur Zertifizierung von Managementsystemen GmbH, a notified body, under registration number 250758 MP23. –
As per Directive 93/42/EEC, the unit is a Class I instrument.
–
For USA: FDA classification Class I.
We would like to provide you with information about safety aspects which must be observed when handling this device. This chapter contains a summary of the most important information concerning matters relevant to instrument safety. Important safety information has been incorporated in this manual and is marked with a warning triangle accordingly. Please give this information your special attention. The correct use of the system is absolutely vital for safe operation. Please make yourself totally familiar with the contents of this manual prior to startup of the instrument. Please also observe the user manuals of any additional equipment. Further information is available from our service department or from authorized representatives.
G-30-1607-en
•
Please observe all applicable accident prevention regulations.
•
The instrument must be connected to a special emergency backup line supply in accordance with the regulations or directives which apply in your country.
OPMI® VARIO on S8, S81 & S88 Suspension Systems
Issue 5.0 Printed on 30. 01. 2009