ConMed Linvatec
ConMed Linvatec Medical Monitors
26” LCD Medical Monitor Instruction Manual Models VP 4726 and VP4726F Rev AA Jan 2009
Instruction Manual
280 Pages
Preview
Page 1
W41-147-004AA.book Page 1 Wednesday, February 18, 2009 2:47 PM
The ConMed Linvatec 26” LCD Medical Monitor Instruction Manual (VP4726 and VP4726F)
E
Manuel d'instruction du moniteur médical LCD ConMed Linvatec 66 cm (VP4726 et VP4726F)
F
ConMed Linvatec 26-Zoll-LCD-Monitor Bedienungsanleitung (VP4726 und VP4726F)
G
Monitor medicale LCD 26" ConMed Linvatec Manuale di istruzioni (VP4726 e VP4726F)
I
Manual de instrucciones del monitor LCD médico ConMed Linvatec de 26 pulgadas (VP4726 y VP4726F)
S
W41-147-004AA.book Page 2 Wednesday, February 18, 2009 2:47 PM
E
Proprietary Information This manual contains information deemed proprietary to Linvatec Corporation. The information contained herein, including all of the designs and related materials, is the sole property of ConMed Linvatec and/or its licensors. ConMed Linvatec and/or its licensors reserve all patent, copyright and other proprietary rights to this document, including all design, manufacturing methodology and reproduction. This document, and any related materials, is confidential and is protected by copyright laws and shall not be duplicated, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties, in whole or in part, without the prior express written consent of ConMed Linvatec. ConMed Linvatec reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes, unless otherwise required by law. Linvatec is a trademark or registered trademark of ConMed Linvatec
Linvatec Corporation 2009. All Rights Reserved. Printed in USA
Record the Model and Serial Numbers of the VP4726 and/or VP4726F LCD Monitor(s) and date received. Retain for future reference. Monitor Model No. Monitor Model No. Monitor Model No.
Serial No Serial No Serial No
Date Date Date
W41-147-004AA.book Page i Wednesday, February 18, 2009 2:47 PM
Table of Contents
1.0
Page
INTRODUCTION 1.1
Intended Use... E-1
1.2
Warnings and Precautions... E-1
1.3
1.2.1
Warnings... E-1
1.2.2
Precautions... E-3
Environmental Directives... E-4
1.4
Symbol Definitions... E-5
1.5
Unpacking and Inspecting the Monitor... E-6
1.6
Returning the Monitor... E-6
1.7
System Indicators... E-7 1.7.1
Front Panel On-Screen Display (OSD) Button Functionality... E-7
1.7.2
Rear Panel... E-8
1.8
Monitor Operation... E-9
1.9
On-Screen Display Menus... E-10 1.9.1
DSUB ANALOG/RGBS Input Source... E-10
1.9.2
DVI OPTICAL / DVI DIGITAL Input Source... E-13
1.9.3
YPbPr Input Source... E-15
1.9.4
SVIDEO / CVIDEO Input Source... E-18
1.9.5
SDI Input Source... E-21
1.10 OSD System Overview... E-24 1.11 Standard Signal Table... E-30 1.12 SDI Video Format... E-31 1.13 VGA (15 Pin D-Sub)... E-31 1.14 DVI In, Out (24 DVI-D)... E-32 1.15 C-Video (BNC)... E-32 1.16 S-Video (BNC)... E-33 1.17 RS232C (D-SUB 9 Pin)... E-33 1.18 SDI (BNC)... E-33 1.19 RGBHV / RGBS / YPbPr (BNC)... E-34 1.20 OPTICAL (available on VP4726F Monitor Only)... E-34 E-i
E
W41-147-004AA.book Page ii Wednesday, February 18, 2009 2:47 PM
Table of Contents
E 2.0
Page
MAINTENANCE 2.1
Life Expectancy... E-35
2.2
Periodic Maintenance... E-35
2.3
Cleaning Instructions... E-35
2.4
Recommended Annual Monitor Maintenance Requirements... E-36
2.5
Technical Specifications... E-38
2.6
Detailed EMC Information... E-41
2.7
Obtaining Parts and Accessories... E-47
2.8
Customer Service... E-48 2.8.1
Assistance... E-48
2.8.2
Repairs... E-48
E-ii
W41-147-004AA.book Page 1 Wednesday, February 18, 2009 2:47 PM
1.0 INTRODUCTION
1.2
I
The words WARNING, PRECAUTION, and NOTE carry special meanings and they should be read carefully.
t is recommended that personnel study this manual before attempting to connect, operate, adjust and/or clean the ConMed Linvatec VP4726 and VP4726F Medical LCD 26” Monitors. The safe and effective use of this equipment requires the understanding of and compliance with all warnings, precautionary notices, and instructions marked on the product, and included in this manual.
WARNING: The safety and/or health of the patient, user, or a third party is at risk. Comply with this warning to avoid injury to the patient, user, or third party. PRECAUTION: This contains information concerning the intended use of the device or accessory. Damage to the equipment is possible if these instructions are not followed.
The VP4726F Monitor is identical to the VP4726 Monitor except it is equipped with Optical input connectors. See “1.20 OPTICAL (available on VP4726F Monitor Only)” on page E-34 for connector information.
1.1
Warnings and Precautions
NOTE: A note is added to provide additional, focused, information.
Intended Use
1.2.1
The VP4726 and VP4726F Medical LCD 26” Monitors are used to display live and recorded images captured with a medical grade camera system or previously recorded using various recording devices.
E-1
Warnings
1.
This equipment is designed for use by medical professionals completely familiar with the required techniques and instructions for use of the equipment. Prior to using the device, read and follow all warning and precautionary notices and instructions marked on the product and included in this manual.
2.
Do not attempt to open or service the monitor, as this may void your warranty. There are no userserviceable parts inside. Removing the cover may introduce an electric shock hazard by exposing you to dangerous high voltages or other risks. If the system malfunctions, return it for service immediately.
E
W41-147-004AA.book Page 2 Wednesday, February 18, 2009 2:47 PM
E
3.
Dangerous voltages are present inside the monitor. The unit should be used only in rooms that comply with recommendations concerning electrical safety when used for medical purposes (as stated in IEC 60601 Series and UL 60601-1).
4.
Never insert anything metallic into the cabinet openings of the monitor. Doing so may cause electric shock.
5.
This equipment is not suitable for use in the presence of flammable anesthetic mixture with air, oxygen, or nitrous oxide.
7.
Some disinfectants and cleaning agents vaporize to form explosive mixtures and, if such agents are used, the vapor must be allowed to disperse before the monitor is put to use.
9.
13. Grounding reliability is achieved only when the monitor is connected to a “hospital only” or “hospital grade” receptacle. Inspect routinely and do not use if damage is discovered.
System installation shall be in accordance with the requirements of IEC 60601-1-1, The Standard for Safety Requirements of Medical Electrical Systems.
6.
8.
12. Equipment grounding is vital for safe operation. Plug power cord into a properly earthed mains supply outlet whose voltage and frequency characteristics are compatible with those listed on the monitor or in this manual. Do not use plug adapters or extension cords; such devices defeat the safety ground and could cause injury.
14. If one or more mains powered units are connected simultaneously to one socket by the means of a distribution box, the sum of the individual leakage currents may exceed the tolerated limits. 15. Be sure to hold the plug, not the cord, when disconnecting the monitor from an electric socket. Doing so may cause electric shock. 16. Do not touch signal input, signal output or other connectors, and the patient simultaneously.
Before connecting the AC power cord to the DC adapter outlet make sure the voltage designation of the DC adapter corresponds to the local electrical supply.
17. If your monitor does not operate normally, in particular, if there are any unusual sounds or smells coming from it, unplug it immediately and return for service.
Disconnect monitor prior to applying cardiac defibrillation to patient.
18. For the protection of service personnel, and for safety during transportation, all devices and accessories that are returned for repair must be prepared for shipment as described in “1.6 Returning the Monitor” on page E-6 of this manual. The manufacturer has the right to refuse to carry out repairs if the product is contaminated.
10. This monitor should not share an electrical outlet or grounding with life supporting or life sustaining equipment. 11. This monitor may not be used in connection with life support equipment.
E-2
W41-147-004AA.book Page 3 Wednesday, February 18, 2009 2:47 PM
1.2.2
Precautions
1.
United States Federal law restricts sale of this device to or on the order of a physician.
2.
The monitor should only be used in compliance with its intended use.
3.
Do not use the monitor with incompatible equipment not authorized by ConMed Linvatec. Doing so may void certifications and/or warranties.
4.
The warranty becomes void and the manufacturer is not liable for direct or resulting damage if:
Rx ONLY
• The monitor or the accessories are improperly used, prepared or maintained; • The instructions in the manual are not adhered to;
5.
Prior to each use the monitor and all associated equipment must be inspected for proper operation.
6.
Do not expose the monitor to moisture, operate in wet areas, or place liquids on or above unit.
7.
Electrical cords and attaching cables used with the monitor must be appropriate for the rated voltage and current, and in compliance with all international, national, and local electrical codes and regulations pertaining to the use of medical devices.
8.
Ensure that the available mains voltage matches the mains voltage data on the rear of the monitor which is located near the appliance inlet module.
9.
Do not excessively bend or kink the instrument power cord.
10. Handle all equipment carefully. If the monitor is dropped or otherwise damaged, return it immediately for service.
• Non-authorized persons open and / or perform repairs, adjustments or alterations to the monitor;
11. Openings in the monitor cabinet are provided for ventilation. To prevent overheating, these openings should not be blocked or covered.
NOTE: Receipt of technical documentation from the manufacturer does not authorize individuals to perform repairs, adjustments, or alterations to the monitor or accessories.
12. Thoroughly clean the monitor as needed (reference “2.3 Cleaning Instructions” on page E-35).
Only authorized service personnel may perform repairs, adjustments or alterations on the monitor and accessories. Any violation will void the manufacturer’s warranty. Authorized service technicians are trained and certified only by the manufacturer.
E-3
E
W41-147-004AA.book Page 4 Wednesday, February 18, 2009 2:47 PM
E
13. External equipment that will be connected to signal input and signal output ports or other connectors shall comply with relevant IEC standard (i.e., IEC 60950 for IT equipment and IEC 60601 series for medical electrical equipment). In addition, all such combinations / systems - shall comply with the standard IEC 60601-1-1 (Safety requirements for medical electrical systems).
1.3
Environmental Directives
WEEE Directive [2002/96/EC] on Waste Electrical and Electronic Equipment The Directive on Waste Electrical and Electronic Equipment obliges manufacturers, importers, and/or distributors of electronic equipment to provide for recycling of the electronic equipment at the end of its useful life.
Any person who connects external equipment to signal input and signal output ports or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. If in doubt, contact a qualified technician or your local representative.
Do not dispose of WEEE in unsorted municipal waste. The WEEE symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of Waste Electrical and Electronic Equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your medical equipment at the end of its useful life for recycling, please contact ConMed Linvatec.
(a) Reorient or relocate the receiving device. (b) Increase the separation between the equipment. (c) Connect the equipment into an outlet on a circuit different from that to which the other devices are connected. (d) Consult the manufacturer or field service technician for assistance.
E-4
W41-147-004AA.book Page 5 Wednesday, February 18, 2009 2:47 PM
1.4
Flammable Anesthetics - Risk of explosion if used in the presence of flammable anesthetics
Symbol Definitions Power Standby / ON
Fragile
Follow instructions for use. This side up Precaution or warning notice
~
3
Electrical hazard. Dangerous voltages are present within the cabinet. Never attempt to repair the equipment. Only trained service personnel may remove the cover, or obtain access to the system components.
Maximum Stacking Keep Dry
Temperature limits for storage and transport
Alternating Current.
Humidity limits for storage and transport
Direct Current
Protective Earth (ground). Pressure limits for storage and transport
Warning - For continued protection against risk of fire, replace only with same type and rating fuse. Waste Electronics and Electrical Equipment (WEEE) Symbol. Regarding European Union endof-life of product. RF Symbol. Non-ionizing Electromagnetic Radiation
Rx ONLY
Caution: Federal Law restricts this device to sale by or on the order of a physician.
E-5
GPIO
General Purpose Input / Output
PACS
Picture Archive Communications System
PIP
Picture in Picture
PBP
Picture By Picture (side by side images)
IPX1
Indicates that the device is protected against the effects of vertically falling water.
E
W41-147-004AA.book Page 6 Wednesday, February 18, 2009 2:47 PM
E
1.5
Unpacking and Inspecting the Monitor
1.6
Returning the Monitor
If it becomes necessary to return the monitor, always use the original packaging. The manufacturer does not take responsibility for damage that has occurred during transportation if the damage was caused by inadequate transport packaging.
Upon receipt, carefully unpack the monitor and accessories. Ensure contents are complete and are free from damage. If any damage is noted contact your ConMed Linvatec Customer Service Representative. Save ALL packaging materials; they may be needed to verify any claims of damage by the shipper.
Contact ConMed Linvatec Customer Service for Return Authorization PRIOR to shipping your monitor for service.
VP4726 / VP4726F LCD 26” Monitor: •
1 - DVI Cable, 6 ft. (IM9021)
•
1 - BNC Cable (8175-06)
•
1 - AC Adapter (023933)
• Owner’s Name
•
2 - DC Cable Terminal male / female (Optional)
• Owner’s Address
•
4 - Screws FH M4x12 (Screws for Vesa mount - Optional)
• Device type and model.
•
2 - Ferrite Core, ZCAT2035-0930A-M-K (Optional)
•
1 - Instruction Manual
Please make sure that all required information has been supplied.
• Owner’s Daytime Telephone Number • Serial Number • Detailed explanation of the damage.
The power cord is sold separately and is packaged in a separate box. •
C7104 Power Cord - 115VAC
•
C7105 Power Cord - 230VAC
E-6
W41-147-004AA.book Page 7 Wednesday, February 18, 2009 2:47 PM
E
❶
❷
1.7
❸ ❹
❺ ❻
❽
❾
➎ MENU Button - With the OSD deactivated,
System Indicators
1.7.1
❼
pressing this button activates the OSD menu. With OSD activated, pressing this button exits the main menu or sub-menu.
Front Panel On-Screen Display (OSD) Button Functionality
➏ Down Arrow - With the OSD deactivated,
press this area to decrease the brightness of the monitor. With the OSD activated, press this area to move the cursor downward.
❶ “POWER” Button - Press to set the
monitor to Normal Mode or Stand-by Mode.
❼ Right Arrow - With the OSD deactivated,
❷ Power Status Indicator - Indicator is off
press this area to increase the contrast of the monitor. With the OSD activated, press this area to enter a sub-menu and increase the adjustment of the selected function.
when monitor is in stand-by mode, and is illuminated green when the monitor is activated.
❸ Up Arrow - With the OSD deactivated, press
❽ INPUT Button - Used to change the
this area to increase the brightness of the monitor. With the OSD activated, press this area to move the cursor upward in a menu.
monitor’s signal source; select DVI OPTICAL / DVI DIGITAL / DSUB ANALOG / SDI YPbPR / RGBS / SVIDEO / CVIDEO. With OSD deactivated, press this button to switch signal inputs.
❹ Left Arrow - With the OSD deactivated,
press this area to decrease the contrast of the monitor. With the OSD activated, press this area to enter a sub-menu and decrease the adjustment of the selected function.
➒ PIP Button - Pressing this button enables
the Picture-In-Picture function. Select PIP, PBP1, PBP2.
E-7
W41-147-004AA.book Page 8 Wednesday, February 18, 2009 2:47 PM
17
E
18
16
❾
10
11
❶
❷ ❸
1.7.2
Rear Panel
12
13
14
15
❹ ❺
❻
❼
❽
12
GREEN / Y Connector
13
BLUE / Pb Connector
14
C-SYNC / H-SYNC Connector
15
VS (V-SYNC) Connector
16
S-VIDEO / Y Connector
❹ DVI IN Connector
17
S-VIDEO / C Connector
➎ DVI OUT Connector
18
Composite (C) VIDEO Connector
❶ AC / DC IN Jack ❷ ON / OFF Switch ❸ OPTICAL IN (OPTIONAL) Connector (Available only on the VP4726F Model)
➏ VGA IN Connector ❼ GPIO Connector ❽ RS232C Connector ➒ HD SDI IN Connector ➓ HD SDI OUT Connector 11
RED / Pr Connector
E-8
W41-147-004AA.book Page 9 Wednesday, February 18, 2009 2:47 PM
1.8
E
Monitor Operation
1.
Connect the DC input jack to the DC IN connector on the back of the monitor.
2.
Plug the female end of the AC Power Cord into the AC Inlet of the DC Adapter.
3.
Plug the AC Power Cord into a Hospital Grade outlet.
4.
Connect the appropriate video source to the monitor.
5.
Apply power to all connected peripheral devices.
6.
Turn the monitor on by pressing the power switch on the back of the monitor.
7.
Set your preferred settings using the OnScreen Menus listed on the following pages.
E-9
W41-147-004AA.book Page 10 Wednesday, February 18, 2009 2:47 PM
E
1.9
On-Screen Display Menus
1.9.1
DSUB ANALOG/RGBS Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast (Range: 0~100).
❸ CLOCK - Increase or decrease the sampling frequency (Range: 0~100).
❹ PHASE - Increase or decrease the phase level (Range: 0~100).
➎ BACK LIGHT - Increase or decrease the back light dimming level (Range: 0~100).
➏ AUTO ADJUST - Fit to the most appropriate screen on the D-SUB Analog signal.
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a sub-menu displays allowing the user to adjust the RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode (Range: 0~100).
❸ GREEN - Green balance- Only works with USER mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER mode (Range: 0~100).
E-10
W41-147-004AA.book Page 11 Wednesday, February 18, 2009 2:47 PM
Image Menu
❶ IMAGE SIZE - Change the image size (Scaling mode) (Full; Fill aspect, 1:1; Normal; Video; Zoom; Video only).
❷ H POSITION - Adjust the horizontal (left or right) position of the displayed source image (Range: 0~100).
❸ V POSITION - Adjust the vertical (up or down) position of the displayed source image (Range: 0~100).
❹ GAMMA - Adjust GAMMA value (VIDEO, BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
➎ FILTER - Set the sharpness of the image (Softest, Soft, Normal, Sharp, Sharpest).
➏ OVER SCAN - Adjust the displayed size ( 0~8) ❼ IMAGE SETTING - Allow selection of one of five user defined image presets.
Setup Menu
❶ LANGUAGE - Change the OSD language
(8 languages - Korean, English, French, Spanish, German, Chinese, Japanese, Italian).
❷ OSD POSITION - Change the OSD position. ❸ DURATION - Adjust time until the OSD Menu will disappear after adjusting the duration (5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all possible input sources until an active video source is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a Preset to the Users Name, etc.
E-11
E
W41-147-004AA.book Page 12 Wednesday, February 18, 2009 2:47 PM
E
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP, PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus are available:
❷ SOURCE - Changes the secondary source. ❸ SIZE - Changes the PIP size (Small, Medium, Large).
❹ POSITION - Changes the PIP location. ➎ SWAP - Swaps the position and size of the Primary and Secondary image.
E-12
W41-147-004AA.book Page 13 Wednesday, February 18, 2009 2:47 PM
1.9.2
DVI OPTICAL / DVI DIGITAL Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast (Range: 0~100).
❸ BACK LIGHT - Adjust the back light dimming level (Range: 0~100).
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a sub-menu displays allowing the user to adjust the RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode (Range: 0~100).
❸ GREEN - Green balance- Only works with USER mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER mode (Range: 0~100).
E-13
E
W41-147-004AA.book Page 14 Wednesday, February 18, 2009 2:47 PM
E
Image Menu
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill aspect, 1:1; Normal).
❷ GAMMA - Adjust GAMMA value (VIDEO, BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
❸ FILTER - Set the sharpness of the image (Softest, Soft, Normal, Sharp, Sharpest).
❹ OVER SCAN - Adjust the displayed size ( 0~8). ➎ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2, USER 3).
➏ ZOOM / PAN - Enlarge the image. ❼ FREEZE FRAME - Freezes the image.
Setup Menu
❶ LANGUAGE - Change the OSD language
(8 languages - Korean, English, French, Spanish, German, Chinese, Japanese, Italian).
❷ OSD POSITION - Change the OSD position (9 Positions).
❸ DURATION - Adjust time until the OSD Menu will disappear after adjusting the duration (5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all possible input sources until an active video source is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a Preset to the Users Name, etc.
E-14
W41-147-004AA.book Page 15 Wednesday, February 18, 2009 2:47 PM
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP, PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus are available:
❷ SOURCE - Changes the secondary source. ❸ SIZE - Changes the PIP size (Small, Medium, Large).
❹ POSITION - Changes the PIP location. ➎ SWAP - Swaps the position and size of the Primary and Secondary image.
1.9.3
YPbPr Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast (Range: 0~100).
❸ SHARPNESS - Adjust the sharpness of the video image (Range: 0~100).
❹ SATURATION - Changes the tone of the color (Range: 0~100).
➎ COLOR - Changes the richness of the color (Range: Green 0~50, Red 0~50).
➏ BACK LIGHT - Increase or decrease the back light dimming level (Range: 0~100).
❼ PHASE - Increase or decrease the phase level (Range: 0~100).
E-15
E
W41-147-004AA.book Page 16 Wednesday, February 18, 2009 2:47 PM
E
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a sub-menu displays allowing the user to adjust the RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode (Range: 0~100).
❸ GREEN - Green balance- Only works with USER mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER mode (Range: 0~100).
Image Menu
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill aspect, 1:1; Normal).
❷ H POSITION - Adjust the horizontal (left or right) position of the displayed source image (Range: 0~100).
❸ V POSITION - Adjust the vertical (up or down) position of the displayed source image (Range: 0~100).
❹ GAMMA - Adjust GAMMA value (VIDEO, BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
➎ FILTER - Set the sharpness of the image (Softest, Soft, Normal, Sharp, Sharpest).
➏ OVER SCAN - Adjust the displayed size ( 0~8) ❼ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2, USER 3).
E-16