Reference Manual
19 Pages
Preview
Page 1
GE Datex-Ohmeda S/5 FM Supplies and Accessories
Conformity according to the Council Directive 93/42/EEC concerning Medical Devices CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed medical practitioner. Outside the USA, check local laws for any restriction that may apply. All specifications are subject to change without notice. Document no. M1023052-01 June, 2004
Datex-Ohmeda Inc. P.O. Box 7550 Madison, WI 53707-7550, USA Tel: +1-608-221 1551 Fax: +1-608-222 9147
Datex-Ohmeda Division, Instrumentarium Corporation P.O. Box 900 FI-00031 DATEX-OHMEDA, FINLAND Tel: +358 10 39411 Fax: +358 9 1463310
www.us.datex-ohmeda.com
www.datex-ohmeda.com/
© Instrumentarium Corp. All rights reserved.
Supplies and Accessories
Table of contents 1 About this document
1
2 Instructions for use
3
Multi-Link ECG accessories ... 3 NIBP cuff hoses ... 4 OxyTip+ pulse oximetry accessories... 5 Temperature adapter cables ... 6 Invasive blood pressure adapter cables... 7
3 List of accessories
9
ECG accessories... 10 NIBP accessories... 13 Pulse oximetry accessories ... 14 Temperature accessories ... 14 Invasive pressure accessories ... 14 Airway gas accessories ... 14 Interfacing cables... 14 Mounting elements... 14 Other ... 15 Device Interfacing Solution ... 15
Supplies and Accessories
1 About this document This document introduces the accessories for the Datex-Ohmeda S/5 FM, and provides supplemental instructions. Also refer to the “User's Guide.” Some of the information in this document may already be included in the “User's Guide” that you have. For those accessories that do not have instructions for use included in this document, please, refer to the accessory package.
IMPORTANT: This document contains very important information about these accessories and their use, please keep it in a safe place near other user documentation.
WARNING: Use only defibrillator-proof cables and invasive pressure transducers approved by Datex-Ohmeda. Using other cables and transducers may cause a safety hazard. Protection against cardiac defibrillator discharge is due in part to the accessories for pulse oximetry (SpO2), temperature (T), and invasive pressure (P) measurement.
NOTE: Please refer to the “User's Guide” for other warnings and cautions.
Calibration check of temperature, NIBP and invasive blood pressures Calibration check of temperature, NIBP and invasive blood pressures should be performed at least once a year by qualified service personnel. Please see the "Technical Reference Manual."
1
GE Datex-Ohmeda S/5 FM
2
Supplies and Accessories
2 Instructions for use All these accessories are indicated for use by qualified medical personnel only.
Multi-Link ECG accessories R=RED (IEC) RA=WHITE (AAMI)
R/RA
L=YELLOW (IEC) LA=BLACK (AAMI)
LEAD I L/LA
R=RED (IEC) RA=WHITE (AAMI)
R/RA
L/LA V1
II
V2
V3
LEAD III
LE AD
1. Multi-Link 5-lead or 12-lead standard cable
L=YELLOW (IEC) LA=BLACK (AAMI)
V4 V5
V6
1 2
3
4 5
6
F/LL
F=GREEN (IEC) LL=RED (AAMI)
F/LL F=GREEN (IEC) LL=RED (AAMI)
N/RL N=BLACK (IEC) RL=GREEN (AAMI)
1 RA
LA
1
RL
2 345 6
LL
RL RA LA LL V V1
2
V2 V3 V4 V5 V6
3
1
Disinfection Wipe the cleaned product with chemical disinfectant, such as ethanol, isopropanol, phenolic disinfectant or glutaraldehyde. NOTE: Do not immerse the products in liquids. Protect from strong UV radiation. Sterilization
Multi-Link ECG accessories enable ECG monitoring with new Datex-Ohmeda S/5 modules.
Starting measurement
3. 4. 5.
3. Multi-Link leadwire set (C2-C6 IEC, V2-V6 AHA)
2
Intended use
1. 2.
2. Multi-Link leadwire set (3 or 5 leads)
Connect the trunk cable to the monitor. Connect the leadwire set to the trunk cable. • For 3-lead ECG, use the Multi-Link 3-lead ECG cable with integrated leadwires or connect a 3 leadwire set to the Multi-Link 5- or 12-lead ECG trunk cable. • For 5-lead ECG, connect a 5 leadwire set to the MultiLink 5- or 12-lead ECG trunk cable. • For 12-lead ECG, connect a 5 leadwire set together with a 5 leadwire C2 -C6 or V2 -V6 set to the MultiLink 12-lead ECG trunk cable. Prepare the skin: shave any hair from the selected electrode sites, and clean and dry the skin. Attach the electrodes to the correct positions. See the monitor user documentation for instructions on positioning the electrodes. Connect the leadwire set to the electrodes.
Sterilize with ethylene oxide (EtO) at a max. temperature of 50°C/122°F or with STERRAD® Systems. After ethylene oxide sterilization, follow the recommendations of the sterilizer manufacturer for the required aeration period.
Precautions Use only supplies and accessories approved by Datex-Ohmeda for proper and accurate functioning of measurement. Using components other than the ones supplied might result in a measurement error. Ensure proper contact of the electrosurgery unit return electrode to the patient to avoid burns at monitor measurement sites. Do not allow humidity or liquid to enter the cables. Do not use cables if you see any visual signs of damages.
CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.
Maintenance Before use, check that the product is intact and clean. NOTE: Do not treat the cables with oils (like household or lubricating) or aggressive fluids or solvents (like acetone). Cleaning Wipe with a cloth moistened with mild detergent or soap solution. Allow the product to dry completely after cleaning.
Ordering information For further information, please consult the Supplies & Accessories Catalog http://supplies.datex-ohmeda.com or your local sales company.
3
GE Datex-Ohmeda S/5 FM
NIBP cuff hoses 1. Cuff hose 2. Cuff of correct size
1 2
E X LIN INDE
Intended use
Sterilization The cuff hoses can be sterilized with ethylene oxide mixture (EtO) at a maximum temperature of +50°C or with STERRAD® Systems. After ethylene oxide sterilization, follow the recommendations from the sterilizer manufacturer for required aeration period.
The cuff hose is used for connecting the NIBP cuffs to new Datex-Ohmeda S/5 modules. The black adult cuff hose includes cuff identification and is recognized by the monitor as an adult cuff hose. The light blue infant hose does not include cuff identification and thus the pediatric NIBP mode has to be selected in the monitor menu.
Precautions
Starting the measurement
Use only supplies and accessories approved by DatexOhmeda for proper and accurate functioning of measurement. Using components other than the ones supplied might result in a measurement error. Mating connectors with force without proper alignment may damage the connectors and prevent proper airflow to the cuff. Make sure no liquid enters the hose.
1.
Connect the cuff hose to the adult size NIBP cuff by placing opposite connectors in contact and locking them together. 2. Plug the NIBP cuff hose to the monitor or module. 3. Refer to the monitor user documentation for detailed information. NOTE: O-rings of hose connectors should be lubricated from time to time.
CAUTION
Maintenance
Federal (USA) law restricts this device to sale by or on the order of a physician.
Cleaning Wipe with a cloth moistened with mild detergent or soap solution.
Ordering information For further information, please consult the Supplies & Accessories catalog http://supplies.datex-ohmeda.com or your local sales company.
Disinfection Disinfect with a chemical disinfectant, such as ethanol (70%), isopropanol, phenolic disinfectant or aldehydes.
4
Supplies and Accessories
OxyTip+ pulse oximetry accessories OXY-E-UN
1. OxyTip+ Interconnect cable
OXY-SE-3
OXY-F-UN
1
OXY-W-UN
OXY-AP
OXY-AF
Sterilization Do not sterilize the sensor or cable.
Intended use OxyTip+ Interconnect Cable connects OxyTip+ SpO2 sensors to new Datex-Ohmeda S/5 modules.
Precautions
Starting the measurement 1. 2.
Use only supplies and accessories approved by DatexOhmeda for proper and accurate functioning of measurement. Using components other than the ones supplied might result in a measurement error. Mating connectors with force without proper alignment may damage the connectors and disrupt the electrical continuity.
Connect the Interconnect Cable to the module. Connect the selected SpO2 sensor to the Interconnect Cable.
Maintenance Cleaning Wipe with a cloth moistened with mild detergent or soap solution. Do not spray or soak the connectors.
CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.
Disinfection Spray or wip with pad moistened with 70% alcohol or 3.4% gluteraldehyde (Cidex). Although discoloration may occur, you may also use 1.6% phenol (Sporicidin), quaternary germicides (Virex), or 0.5% sodium hypochlorite.
Ordering information For further information, please consult the Supplies & Accessories Catalog http://supplies.datex-ohmeda.com or your local sales company.
5
GE Datex-Ohmeda S/5 FM
Temperature adapter cables 1. Adapter cable for temperature probes
2
2. Reusable temperature probe 2
3. Adapter cable for disposable temperature probes
1
4. Disposable temperature probe interconnect cable
4 1
3
Sterilization Sterilize with ethylene oxide gas (EtO) at a maximum temperature of +50 °C/ 122 °F or with STERRAD® Systems. After ethylene oxide sterilization, follow the recommendations from the sterilizer manufacturer for required aeration period.
Intended use The temperature adapter cables are intended to be used for connecting one or two reusable or disposable temperature probes to new Datex-Ohmeda S/5 modules.
Starting the measurement 1. 2. 3.
Precautions
Connect the adapter cable to the monitor or module. Connect the other end of the adapter cable to the reusable temperature probe or to the disposable temperature interconnect cable. Connect the disposable temperature probe to the disposable temperature probe interconnect cable.
Use only supplies and accessories approved by DatexOhmeda for proper and accurate functioning of the measurement. Substitution of a component with other than that supplied might result in measurement error. Mating connectors with force without proper alignment may damage the connectors and disrupt the electrical continuity.
Maintenance Cleaning Wipe with a cloth moistened with mild detergent or soap solution.
Do not entwine this cable with other electrical cables.
CAUTION
Disinfection Disinfect with a chemical disinfectant, such as ethanol, propanol, phenolic disinfectant or glutaraldehyde NOTE: Do not immerse the cable in liquids.
Federal (USA) law restricts this device to sale by or on the order of a physician.
Ordering information For further information, please consult the Supplies & Accessories Catalog http://supplies.datex-ohmeda.com or your local sales company.
6
Supplies and Accessories
Invasive blood pressure adapter cables 1. Adapter cable for the InvBP transducer 2. Transducer 3. Adapter cable for dual InvBP measurement
1
Sterilization Sterilize with ethylene oxide gas (EtO) at a maximum temperature of +50 °C/ 122 °F or with STERRAD® Systems. After ethylene oxide sterilization, follow the recommendations from the sterilizer manufacturer for required aeration period.
Intended use These invasive blood pressure adapter cables are intended to be used for connecting one or two invasive blood pressure transducers to new Datex-Ohmeda S/5 modules.
Starting the measurement 1. 2. 3. 4.
Precautions
Connect the single adapter cable to suitable transducer products for which it is designed. Plug the adapter cable to the module, or to the dual invasive pressure adapter cable if two invasive pressures are monitored simultaneously. Please, refer to the monitor’s user documentation for detailed information. When the invasive blood pressure monitoring is completed, disconnect the cable from the transducer product and monitor.
Use only supplies and accessories approved by DatexOhmeda for proper and accurate functioning of the measurement. Substitution of a component with other than that supplied might result in measurement error. Mating connectors with force without proper alignment may damage the connectors and disrupt the electrical continuity. Do not entwine this cable with other electrical cables.
Maintenance
CAUTION
Cleaning Wipe with a cloth moistened with mild detergent or soap solution. Allow the product to dry completely after cleaning.
Federal (USA) law restricts this device to sale by or on the order of a physician.
Ordering information
Disinfection Wipe the cleaned product with a chemical disinfectant, such as ethanol, propanol, phenolic disinfectant or glutaraldehyde NOTE: Do not immerse the cable in liquids.
For further information, please consult the Supplies & Accessories catalog http://supplies.datex-ohmeda.com or your local sales company
7
GE Datex-Ohmeda S/5 FM
8
Supplies and Accessories
3 List of accessories The accessories below are approved and specified for the Datex-Ohmeda S/5 FM. Patient accessories designed for use with this device are made of biocompatible materials conforming to requirements of the standard EN 30993 Biological Evaluation of Medical Devices and therefore do not contain toxic ingredients or primary skin irritants. The conformity is based either on laboratory testing or material knowledge and the long history of the materials used. Please note that some products are not available worldwide. You can check the availability with your local Datex-Ohmeda office or distributor. Please, also refer to our catalog: http://supplies.datexohmeda.com/DO Explanation of symbols Symbol
What it means Batch code Catalog number Does not contain latex Caution, consult accompanying documents Date of manufacture
9
GE Datex-Ohmeda S/5 FM
ECG accessories Multi-Link ECG Cable Adapters
Multi-Link 3-lead ECG Trunk Cables
414370-001 Multi-Link 5-Lead DIN Adapter To convert 5-Lead trunk cable for use with 5-Lead DIN style radiotranslucent leadwires 414370-002 Multi-Link 3-Lead DIN Adapter To convert 5-Lead trunk cable for use with 3-Lead DIN style radiotranslucent leadwires
412944-001 Multi-Link 3-lead ECG Trunk Cable, DIN, AAMI/AHA, 3.6 m/12 ft 412944-002 Multi-Link 3-lead ECG Trunk Cable, DIN, IEC, 3.6 m/12 ft
Multi-Link 3-Lead Integrated Cable and Leadwire Systems 2001292-001 Multi-Link 3-Lead ECG Cable with Integrated Grabber Leadwires, AHA, 3.6 m/12 ft 2001292-002 Multi-Link 3-Lead ECG Cable with Integrated Grabber Leadwires, IEC, 3.6 m/12 ft
Multi-Link ECG Leadwire Sets - Grouped - Grabber 412681-001 Multi-Link 5-Leadwire Set, Grouped, Grabber, AHA, 74 cm/29 in, 5/set 412681-002 Multi-Link 5-Leadwire Set, Grouped, Grabber, AHA, 130 cm/51 in, 5/set 412681-003 Multi-Link 5-Leadwire Set , Grouped , Grabber, IEC, 74 cm/29 in, 5/set 412681-004 Multi-Link 5-Leadwire Set, Grouped, Grabber, IEC, 130 cm/51 in, 5/set 412681-005 Multi-Link 5-Leadwire Set , Grouped, Grabber, AHA, Mixed Length - RL, LL, V: 130 cm/51 in, RA, LA: 74 cm/29 in, 5/set 412681-006 Multi-Link 5-Leadwire Set, Grouped, Grabber, IEC, Mixed Length - N, F, C: 130 cm/ 51 in, R,L: 74 cm/29 in, 5/set 412682-001 Multi-Link 3-Leadwire Set, Grouped, Grabber, AHA, 74 cm/29 in, 3/set 412682-002 Multi-Link 3-Leadwire Set, Grouped, Grabber, AHA, 130 cm/51 in, 3/set 412682-003 Multi-Link 3-Leadwire Set, Grouped, Grabber, IEC, 74 cm/29 in, 3/set 412682-004 Multi-Link 3-Leadwire Set, Grouped, Grabber, IEC, 130 cm/51 in, 3/set
Multi-Link 5-Lead Standard ECG Trunk Cables 412931-001 Multi-Link 5-lead Standard ECG Cable, AHA, 3.6 m/12 ft 412931-002 Multi-Link 5-lead Standard ECG Cable, IEC, 3.6 m/12 ft 412931-021 Multi-Link 5-lead Standard ECG Cable, AHA, 6 m/20 ft 412931-022 Multi-Link 5-lead Standard ECG Cable, IEC, 6 m/20 ft
Multi-Link 12-Lead Standard ECG Trunk Cables 416035-001 Multi-Link 12-lead Standard ECG Cable, AHA, 3.6 m/12 ft 416035-002 Multi-Link 12-lead Standard ECG Cable, IEC, 3.6 m/12 ft 416035-100 Multi-Link V-lead Dust Cap for 12-Lead ECG Cable
10
Supplies and Accessories Multi-Link ECG Leadwire Sets - Individually Replaced - Snap
Multi-Link ECG Leadwire Sets - Individually Replaced - Grabber
411200-001 Multi-Link 5-Leadwire Set, Snap , AAMI/AHA, 74 cm/29 in, 5/set 411200-002 Multi-Link 5-Leadwire Set, Snap , AAMI/AHA, 130 cm/51 in, 5/set 411200-003 Multi-Link 5-Leadwire Set, Snap , IEC, 74 cm/29 in, 5/set 411200-004 Multi-Link 5-Leadwire Set, Snap , IEC, 130 cm/51 in, 5/set 411200-005 Multi-Link 5-Leadwire Set, Snap , AAMI/AHA, Mixed Length - RL, LL, V:130 cm/51 in, RA, LA: 74 cm/29 in, 5/set 416468-001 Multi-Link 5-Leadwire Set, Snap, V2-V6, AAMI/AHA, 130 cm/51 in, 5/set 416468-002 Multi-Link 5-Leadwire Set, Snap, C2-C6, IEC, 130 cm/51 in, 5/set 416468-003 Multi-Link 5-Leadwire Set, Snap, V2-V6, AAMI/AHA, 74 cm/29 in, 5/set 416468-004 Multi-Link 5-Leadwire Set, Snap, C2-C6, IEC, 74 cm/29 in, 5/set
414556-001 Multi-Link 5-Leadwire Set, Grabber, AAMI/AHA, 74 cm/29 in, 5/set 414556-002 Multi-Link 5-Leadwire Set, Grabber, AAMI/AHA, 130 cm/51 in, 5/set 414556-003 Multi-Link 5-Leadwire Set, Grabber, IEC, 74 cm/29 in, 5/set 414556-004 Multi-Link 5-Leadwire Set, Grabber, IEC, 130 cm/51 in, 5/set 414556-005 Multi-Link 5-Leadwire Set, Grouped, Grabber, AAMI/AHA, Mixed Length - RL, LL, V: 130 cm/51 in, RA, LA: 74 cm/29 in, 5/set 414556-006 Multi-Link 5-Leadwire Set, Grouped, Grabber, IEC, Mixed Length - N, F, C: 130 cm/51 in, R, L: 74 cm/29 in, 5/set 416467-001 Multi-Link 5-Leadwire Set, Grabber, AAMI/AHA, V2-V6, 130 cm/51 in, 5/set 416467-003 Multi-Link 5-Leadwire Set, Grabber, AAMI/AHA, V2-V6, 74 cm/29 in, 5/set 416467-002 Multi-Link 5-Leadwire Set, Grabber, IEC, C2-C6, 130 cm/51 in, 5/set 416467-004 Multi-Link 5-Leadwire Set, Grabber, IEC, C2-C6, 74 cm/29 in, 5/set
Multi-Link ECG Leadwires - Individually Replaced Snap
Multi-Link ECG Leadwires - Individually Replaced Grabber
412596-001 Multi-Link Leadwire, Snap, AAMI/AHA, LL, 7 4 cm/29 in 412596-002 Multi-Link Leadwire, Snap, AAMI/AHA, RA, 74 cm/29 in 412596-003 Multi-Link Leadwire, Snap, AAMI/AHA, RL, 74 cm/29 in 412596-004 Multi-Link Leadwire, Snap, AAMI/AHA, LA, 74 cm/29 in 412596-005 Multi-Link Leadwire, Snap, AAMI/AHA, V1, 74 cm/29 in 412596-101 Multi-Link Leadwire, Snap, AAMI/AHA, LL, 130 cm/51 in 412596-102 Multi-Link Leadwire, Snap, AAMI/AHA, RA, 130 cm/51 in 412596-103 Multi-Link Leadwire, Snap, AAMI/AHA, RL, 130 cm/51 in 412596-104 Multi-Link Leadwire, Snap, AAMI/AHA, LA, 130 cm/51 in 412596-105 Multi-Link Leadwire, Snap, AAMI/AHA, V1, 130 cm/51 in
412680-001 Multi-Link Leadwire, Grabber, Red, LL, AAMI/AHA, 74 cm/29 in 412680-002 Multi-Link Leadwire, Grabber, White, RA, AAMI/AHA, 74 cm/29 in 412680-003 Multi-Link Leadwire, Grabber, Green, RL, AAMI/AHA, 74 cm/29 in 412680-004 Multi-Link Leadwire, Grabber, LA, AAMI/AHA, 74 cm/29 in 412680-005 Multi-Link Leadwire, Grabber, Brown, V1, AAMI/AHA, 74 cm/29 in 412680-101 Multi-Link Leadwire, Grabber, Red, LL, AAMI/AHA, 130 cm/51 in 412680-102 Multi-Link Leadwire, Grabber, White, RA, AAMI/AHA, 130 cm/51 in 412680-103 Multi-Link Leadwire, Grabber, Green, RL, AAMI/AHA, 130 cm/51 in 412680-104 Multi-Link Leadwire, Grabber, Black, LA, AAMI/AHA, 130 cm/51 in 412680-105 Multi-Link Leadwire, Grabber, Brown, V1, AAMI/AHA, 130 cm/51 in 416447-011 Multi-Link Leadwire, Grabber, Brown, V2, AAMI/AHA, 130 cm/51 in 416447-012 Multi-Link Leadwire, Grabber, Brown, V3, AAMI/AHA, 130 cm/51 in 416447-013 Multi-Link Leadwire, Grabber, Brown, V4, AAMI/AHA, 130 cm/51 in 416447-014 Multi-Link Leadwire, Grabber, Brown, V5, AAMI/AHA, 130 cm/51 in 416447-015 Multi-Link Leadwire, Grabber, Brown, V6, AAMI/AHA, 130 cm/51 in
Multi-Link ECG Leadwire Sets - Grouped - Snap 411202-001 Multi-Link 5-Leadwire Set, Grouped, Snap, AAMI/AHA, 74 cm/29 in, 5/set 411202-002 Multi-Link 5-Leadwire Set, Group, Snap, AAMI/AHA, 130 cm/51 in, 5/set 411202-003 Multi-Link 5-Leadwire Set , Group , Snap, IEC, 74 cm/29 in, 5/set 411202-004 Multi-Link 5-Leadwire Set, Group, Snap, IEC, 130 cm/51 in, 5/set
11
GE Datex-Ohmeda S/5 FM 411202-005 Multi-Link 5-Leadwire Set, Group, Snap, AAMI/AHA, Mixed Length - RL,LL,V: 130 cm/ 51 in, RA,LA: 74 cm/29 in, 5/set 411202-006 Multi-Link 5-Leadwire Set, Group, Snap, IEC, Mixed Length - RL, LL, V: 130 cm/ 51 in, RA,LA: 74 cm/29 in, 5/set
403751-014 Leadwire Set, Radiotranslucent, Grabber/DIN, IEC, 122 cm/48 in, 5/set 403751-015 Leadwire Set, Radiotranslucent, Grabber/DIN, AAMI/AHA, limb leads, 5/set
Multi-Link ECG Leadwire Sets - Radiotranslucent Grabber/DIN Connectors - Individually Replaced
Multi-Link ECG Leadwire Sets - Grouped - Snap (cont.)
403751-006 Leadwire Set, Radiotranslucent, Grabber/DIN, AAMI/AHA, 122 cm/48 in 403751-008 Leadwire Set, Radiotranslucent, Grabber/DIN, AAMI/AHA, 152 cm/60 in
411203-001 Multi-Link 3-Leadwire Set, Group, Snap, AAMI/AHA, 74 cm/29 in, 3/set 411203-002 Multi-Link 3-Leadwire Set, Group, Snap, AAMI/AHA, 130 cm/51 in, 3/set 411203-003 Multi-Link 3-Leadwire Set, Group, Snap, IEC, 74 cm/29 in, 3/set 411203-004 Multi-Link 3-Leadwire Set, Group, Snap, IEC, 130 cm/51 in, 3/set
Multi-Link Cable and Leadwire Management Accessories 411195-004 Multi-Link Combiner, 5-lead, Limb Lead, 3/pack 414763-002 Multi-Link Leadwire Separator, 3-lead, Limb Lead 416212-001 Multi-Link Bedsheet Clip 401498-004 ECG Cable Clips, 50/pack
Multi-Link ECG Leadwire Sets - Individually Replaced - Universal/Banana Plug 417949-001 Multi-Link Leadwire Set, Universal/Banana Plug, AAMI/AHA, 74 cm/29 in, 5/set 417483-201 Multi-Link Leadwire Set, Universal/Banana Plug, AAMI/AHA, V2-V6, 130 cm/51 in, 5/set 417483-401 Multi-Link Leadwire Set, Universal/Banana Plug, AAMI/AHA, V2-V6, 74 cm/29 in, 5/set
Compatibility ECG Trunk Cables - for using 300 series leadwire sets below M1020453 Compatibility ECG Trunk Cable, 3-lead, from Multi-Link connector to 300 Series Leadset, IEC, 3.0 m/10 ft M1020454 Compatibility ECG Trunk Cable, 3-lead, from Multi-Link connector to 300 Series Leadset, AHA, 3.0 m/10 ft M1020541 Compatibility ECG Trunk Cable, 5-lead, from Multi-Link connector to 300 Series Leadset, IEC, 3.0 m/10 ft M1020546 Compatibility ECG Trunk Cable, 5-lead, from Multi-Link connector to 300 Series Leadset, AHA, 3.0 m/10 ft
Multi-Link ECG Leadwire Sets - Radiotranslucent 403751-019 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/Grabber, AAMI/AHA, 122 cm/48 in, 5/set 403751-020 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/Grabber, AAMI/AHA, 122 cm/48 in, 10/set 403751-023 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/Grabber, AAMI/AHA, 152 cm/60 in, 5/set 403751-024 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/Grabber, AAMI/AHA, 152 cm/60 in, 10/set 403751-033 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/Grabber, IEC, 152 cm/60 in, C2-C6, 5/set 403751-101 Multi-Link Leadwire Set, Radiotranslucent/ Multi-Link/ Grabber, Gray Generic Connectors, 122 cm/48 in, 5/set
300 Series Leadwire Sets - when using Compatibility ECG Trunk Cables above
Leadwire sets, IEC color coding 545315 3 Leadwire Set, clip, 0.75 m/2.5 ft 545316 5 Leadwire Set, clip, 1.25 m/4.1 ft 8001960 3 Leadwire Set, clip, 1.5 m/4.9 ft 8001961 5 Leadwire Set, clip, 1.5 m/4.9 ft
Leadwire sets, AAMI color coding 545317 3 Leadwire Set, clip, 0.75 m/2.5 ft 545318 5 Leadwire Set, clip, 1.25 m/4.1 ft 545327 3 Leadwire Set, snap, 0.75 m/2.5 ft 545328 5 Leadwire Set, snap, 1.25 m/4.1 ft 8001958 3 Leadwire Set, clip, 1.5 m/4.9 ft 8001959 5 Leadwire Set, clip, 1.5 m/4.9 ft
Multi-Link ECG Leadwire Sets - Radiotranslucent Grabber/ DIN Connectors - Sets 403751-007 Leadwire Set, Radiotranslucent, Grabber/DIN, AAMI/AHA, 122 cm/48 in, 5/set 403751-009 Leadwire Set, Radiotranslucent, Grabber/DIN, AAMI/AHA, 152 cm/60 in, 5/set
12
Supplies and Accessories 2755
Replacement Leads: IEC 545340 545341 545342 545343 545347 545348
2751E
Clip Lead R, 0.75 m/2.5 ft Clip Lead F, 0.75 m/2.5 ft Clip Lead L, 0.75 m/2.5 ft Clip Lead C, 0.75 m/2.5 ft Clip Lead F, 1.25 m/4.1 ft Clip Lead N, 1.25 m/4.1 ft
2752E 2753E 002756E
Replacement Leads: AAMI/AHA
2754E
545344 Clip Lead LA, 0.75 m/2.5 ft 545345 Clip Lead V, 0.75 m/2.5 ft 545358 Clip Lead LL, 0.75 m/2.5 ft 545359 Clip Lead RA, 0.75 m/2.5 ft 545346 Clip Lead LL, 1.25 m/4.1 ft 545349 Clip Lead RL, 1.25 m/4.1 ft 545350 Snap Lead LL, 0.75 m/2.5 ft 545351 Snap Lead LA, 0.75 m/2.5 ft 545352 Snap Lead RA, 0.75 m/2.5 ft 545353 Snap Lead V, 0.75 m/2.5 ft 545354 Snap Lead LL, 1.25 m/4.1 ft 545355 Snap Lead RL, 1.25 m/4.1 ft 8003274 Clip Lead LL, 1.5 m/4.9 ft 8003275 Clip Lead V, 1.5 m/4.9 ft 8003276 Clip Lead RL, 1.5 m/4.9 ft
002757E 2755E
Dura-Cuf, Thigh, Brown, 38 - 50 cm, pkg of 5 pcs Dura-Cuf, Child, Green, 12 - 19 cm, pkg of 1 pcs Dura-Cuf, Small Adult, Royal Blue, 17 - 25 cm, pkg of 1 pcs Dura-Cuf, Adult, Navy, 23 - 33 cm, pkg of 1 pcs Dura-Cuf, Adult Long, Navy, 23 - 33 cm, pkg of 1 pcs Dura-Cuf, Large Adult, Wine, 31 - 40 cm, pkg of 1 pcs Dura-Cuf, Large Adult Long, Wine, 31 - 40 cm, pkg of 1 pcs Dura-Cuf, Thigh, Brown, 38 - 50 cm, pkg of 1 pcs
Reusable color coded latex-free cuffs 572429 Large adult cuff, red 572428 Standard adult cuff, blue 572427 Small adult cuff, gray 572426 Child cuff, green 572425 Infant cuff, tan 8002248 Long large adult cuff, red 8001997 Thigh NIBP cuff
NIBP accessories
Disposable Soft-Cufs
NOTE: The NIBP measurement is intended for patients who weigh 5 kg (11 lb) and up. NOTE: The NIBP cuffs listed below are latex-free.
NOTE: Soft-Cufs are disposable and interchangeable with the disposable cuffs of the same size listed below. 2451 Soft-Cuf, Child, Green/White, 12 -19 cm, pkg of 20 pcs 2452 Soft-Cuf, Small Adult, Lt. Blue/White, 17 - 25 cm, pkg of 20 pcs 2453 Soft-Cuf, Adult, Navy/White, 23 - 33 cm, pkg of 20 pcs 2454 Soft-Cuf, Adult Long, Navy/White, 23 - 33 cm, pkg of 20 pcs 2455 Soft-Cuf, Large Adult, Rose/White, 31 - 40 cm, pkg of 20 pcs 2456 Soft-Cuf, Large Adult Long, Rose/White, 31 - 40 cm, pkg of 20 pcs 2457 Soft-Cuf, Thigh, Brown/White, 38 - 50 cm, pkg of 20 pcs
2021285-001 Adult NIBP cuff hose with cuff identification, black, 3.6 m/12 ft 414874-001 Infant/Neonatal NIBP cuff hose, without cuff identification, light blue 330085 Cuff adapter from male/male to male/female 8001997 Thigh NIBP cuff, 44 - 57 cm
Reusable Dura-Cufs NOTE: Dura-Cufs are reusable and interchangeable with the reusable color coded cuffs of the same size listed below. 2751 Dura-Cuf, Child, Green, 12 - 19 cm, pkg of 5 pcs 2752 Dura-Cuf, Small Adult, Royal Blue, 17 - 25 cm, pkg of 5 pcs 2753 Dura-Cuf, Adult, Navy, 23 - 33 cm, pkg of 5 pcs 002756 Dura-Cuf, Adult Long, Navy, 23 - 33 cm, pkg of 5 pcs 2754 Dura-Cuf, Large Adult, Wine, 31 - 40 cm, pkg of 5 pcs 002757 Dura-Cuf, Large Adult Long, Wine, 31 - 40 cm, pkg of 5 pcs
Disposable cuffs 8001991 Long large adult cuff, pkg of 10 pcs 8001992 Large adult cuff, pkg of 10 pcs 8002562 Long standard adult cuff, pkg of 10 pcs 8001993 Standard adult cuff, pkg of 10 pcs 8001994 Small adult cuff, pkg of 10 pcs 8001995 Child cuff, pkg of 10 pcs 572403 Infant cuff #3, pkg of 10 pcs 572404 Infant cuff #4, pkg of 10 pcs 572405 Infant cuff #5, pkg of 10 pcs
13
GE Datex-Ohmeda S/5 FM
Pulse oximetry accessories
Invasive pressure accessories
OXY-ES3
2005772-001 Dual invasive blood pressure adapter cable 700078-001 Utah transducer adapter cable 700077-001 Becton & Dickinson transducer adapter cable
OxyTip+ Interconnect Cable
OxyTip+ Reusable SpO2 Sensors OXY-E-UN
OxyTip+ Interconnect Ear Sensor with Universal connector OXY-SE-3 OxyTip+ Sensitive Skin Sensor OXY-F-UN OxyTip+ Interconnect Finger Sensor with Universal connector OXY-W-UN OxyTip+ Interconnect Wrap sensor with Universal connector
Airway gas accessories 8002174 Mini D-fend, pkg of 10 pcs
Disposable airway adapters 73385 73386
OxyTip+ Adhesive Sensors OXY-AP OXY-AF
OxyTip+ Adult/Pediatric Adhesive Sensor (10/package, 25/package) OxyTip+ AllFit Adhesive Sensor (10/package)
Anesthesia gas sampling lines 73318 73319 733188 733199 73306
Temperature accessories 402015-004 Dual temperature cable, 8 inches, accepts YSI 400 series probes 2022009-001 Single temperature adapter cable, 8 inches, accepts YSI 400 series probes
165612
Disposable, 2 m/7 ft, pkg of 10 pcs Disposable, 3 m/10 ft, pkg of 10 pcs Disposable, 2 m/7 ft, pkg of 100 pcs Disposable, 3 m/10 ft, pkg of 100 pcs Disposable, 6 m/19.7 ft, pkg of 10 pcs
Nasal sampling lines 878033 878034 878035
Reusable probes 16560 165602 16561 165622 165611
Straight T-adapter, pkg of 10 pcs Elbow adapter, pkg of 10 pcs
Skin temp probe, 3.5 m/11.5 ft Skin temp probe, 1.5 m/4.9ft Central temp probe, adult, 2.8 m/9 ft Central temp probe, adult, 1.5 m/4.9 ft Central temp probe, pedi, 2.8 m/9 ft Central temp probe, pedi, 1.5 m/4.9 ft
Nasal sampling line, pediatric, pkg of 10 pcs Nasal sampling line, adult, pkg of 10 pcs Nasal sampling line, large adult, pkg of 10 pcs
Calibration accessories 755534 755580
D-gate calibration gas regulator Quick Cal calibration gas, pkg of 4 pcs
Low dead space adapters 8001540 For ET tubes with ID 2.5 mm 8001541 For ET tubes with ID 3.0 mm 8001543 For ET tubes with ID 3.5 mm 8000062 For ET tubes with ID 4.0 mm 8000063 For ET tubes with ID 5.0 mm
Disposable probes 8001642 Skin temperature probe, pkg of 25 8001643 Central temperature probe 12F, pkg of 25 pcs 8001644 Central temperature probe 9F, pkg of 25 pcs
Interfacing cables
Esophageal stethoscopes
881167 78031 713701
8002910 Esophageal stethoscope with temperature probe, 9F 8002911 Esophageal stethoscope with temperature probe, 12F 8002908 Esophageal stethoscope with temperature probe, 18F 8002909 Esophageal stethoscope with temperature probe, 24F
UPI-PC serial cable, 3 m/10 ft Serial to parallel converter interface cable Parallel printer cable
Mounting elements 572238 572235 8000725 8000726
14
Wall mount, 15” pivoting arm Roll stand Wall mount, 12” fixed arm Counter top mount
Supplies and Accessories
Other M1008142 M1020847 74205 85969 78030 78032
Device Interfacing Solution
Battery Multi I/O Adapter with connectors for serial port, network ID and K-CREMCO Thermal recorder paper, 20 rolls Cleaning fluid Serial to parallel converter Gender changer (for parallel printers)
8001460 8001461 8001433 900501 900502 900503
Simulators M1010831 M1010832 M1010832 M1010832 M1010846
Hemodynamic simulator Adapter cable for temperature simulator (Fluke Biomedical MedSim) Adapter cable for invasive blood pressure simulator (Fluke Biomedical MedSim) Adapter cable for temperature simulator (Fluke Biomedical Lionheart & MPS450) Adapter cable for invasive blood pressure simulator (Fluke Biomedical Lionheart & MPS450)
Accessory kits M1022220 M1022222 M1022225 M1022227 M1023471
Basic accessory kit for new S/5 modules, IEC Basic accessory kit for new S/5 modules, AAMI/AHA Advanced accessory kit for new S/5 modules, IEC Advanced accessory kit for new S/5 modules with ECG snaps, AAMI/AHA Advanced accessory kit for new S/5 modules with ECG grabbers, AAMI/AHA
15
Small device mount Small IV pole mount BUS extension cable Cable, 1 m/3 ft Cable, 2 m/7 ft Cable, 6 m/20 ft