Deltec 3000 and Deltec Mirco 3100 Operators Guide

Operators Guide

2 Pages

Model 3000 and Model 3100 Micro Modular Infusion Systems  O P E R AT O R ’ S G U I D E PRIMING 1. Remove administration set (tubing) from pouch. Discard if package is damaged or if protective end caps are missing or loose inside package. 2. Close lower roller clamp.Verify upper clamp is open. 3. Insert spike into solution container. Fill drip chamber at least one-third full. A completely filled drip chamber is acceptable. 4. Prime administration set by inverting cassette with flat side facing you. Slowly open lower roller clamp and allow solution to fill entire set. When all air has been expelled, close lower roller clamp. 5. Hang solution container so bottom of drip chamber is at least 6 to 12 inches above pump.  PUMP OPERATION  Options  Occlusion Alarm Setting  Total Volume  *  Primary  Rate  Secondary  Volume to be Infused  1  2  3  4  5  6  7  8  9  Options  2. Hold the cassette with flat side facing you. Place cassette in pump by aligning 4 holes in cassette with 4 pins.  3. Place safety clip in slot and push fully inward.  Rate  Secondary  Volume to be Infused  Run  Hold  5. Press Rate and enter desired rate.  Occlusion Alarm Setting  Primary  1  2  3  4  5  6  7  8  9  0  1. Pull door latch to open door.  Total Volume  *  Run  Hold  0  6. Press Volume to be Infused and enter desired volume.  4. Close and latch door.  Pump  Options  Total Volume  *  Occlusion Alarm Setting  Rate  Primary  Volume to be Infused  Secondary  1  2  3  4  5  6  7  8  9  Occlusion Alarm Setting  Primary  Rate  Secondary  Volume to be Infused  Run  Hold  0  Total Volume  *  Options  1  2  3  4  5  6  7  8  9  Options  Run  Total Volume  *  Primary  Rate  Secondary  Volume to be Infused  1  2  3  4  5  6  7  8  9  Hold  (Optional Operation)  (Optional Operation)  7. Press Total Volume and press * to clear previous total volume.  8. Press Occlusion Alarm Setting to select the correct setting.  9. Open roller clamp.  Occlusion Alarm Setting  Run  Hold  0  10. Press Run to begin infusion. To stop infusion press Hold. When Volume to be Infused reaches zero, pump switches automatically to KVO rate.  SECONDARY INFUSION  1. Press Hold. 2. Press Secondary.  p  Vo  3. Press Rate and enter secondary rate. Primary  Secondary  Options  Total Volume  *  Occlusion Alarm Setting  Primary  Rate  Secondary  Volume to be Infused  On  1  2  3  4  5  6  7  8  9  0  .  Run  Hold  1  2  3  4  5  6  7  8  9  0  .  4. Press Volume to be Infused and enter secondary volume. 5. Press Run.  Deltec SIMS Deltec, Inc., St. Paul, MN 55112 U.S.A.  On Off Charge  Battery  Silence  Modular 3000  Distributed by SIMS Deltec, Inc. U.S. Patent No. 4,236,880 ©1999 SIMS Deltec, Inc. All rights reserved. Printed in U.S.A.  8/99  19969
File Type: PDF
File Size: 135 KB
File Name: Deltec - Deltec 3000 and Deltec Mirco 3100 Operators Guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions