Parts List and Quick Setup Guide
2 Pages
Preview
Page 1
fms duo + Parts List ®
Ports and Connectors on the Back
1 On/Off Switch
4 Shaver Interface Port
2 Fuses
5 Foot Pedal Port
Basic Features on the Front
Transparent Safety Cover 1
12 Alarm
3 Power Socket
1
1
Tension Rocker Arm 2
13 Shaver Suction Setting Button
Pressure Display 3
14 Suction Roller Pump
Power Button 4 Irrigation Roller Pump 5
(FMS Shaver Only) 5
Cannula Suction Setting Button 6 Irrigation Auto-Locking Port. 7
14
3
7
16 Lavage Mode Button
12
4
17
Pressure Adjustment Buttons 8
4 1 5
Pressure Transducer Port 10
3
16
6
19 Pinch Valve Button 15
11
10
19
Pump Run/Stop Button 11 21
One Day Set Irrigation Tube
17 Patient Set Auto-Locking Port 18 Pinch Valve
13
8
9
Fill Chamber Button 9
2
15 Shaver Hand Piece Port
2
18
20 Tube Holder
20
21 Fill Chamber Holder
[Red Surface]
Clamp
Pressure Chamber
Auto-Locking Device
Clamp
Clamp
[One-Color 185]
SHAVER WASTE
OUTFLOW CANNULA
Clamp
Auto-Locking Device
[Black&White Only] INFLOW
Patient Set With One-way Valve
Clamp
Shaver Interface Cable
fms duo®+ Power Cable
Waste Collection Bag
Foot Pedal
10,000 ml
[dark backgrounds]
9,000 ml
5,000 ml
GR OUP
4,000 ml
CANN
UL
CT A SU
ION
BAG
6,000 ml
WASTE
7,000 ml
ON
LLECTI CO
8,000 ml
LAVA
Re
f 2 8138
0
3,000 ml
GE 2,000 ml
1,000 ml
Shaver Interface Power Cable
500 ml
P/N 901015. Rev. A 03/08
©DePuy Mitek, Inc. 2008. All rights reserved. Printed in the USA.
1-800-382-4682 Red pedal is a timed cycle to control bleeding
www.depuymitek.com [light backgrounds] 2 Portals in the knee
3 Portals in the knee
Blue pedal increases flow only Wall suction DO NOT CONNECT
Open only when flow is required “One Day Set” Irrigation tube
Shoulder with working cannula
(with one-way valve)
Patient Set
d u o ® + f m s S e t u p D i a g r a m Q
U
I
C
K
S
E
T
U
P
G
U
I
D
E
fms duo + ®
Fluid Management System with Shaver Interface (Using Irrigation Tube as "One Day Set"*)
Sterile procedures should be followed wherever appropriate. (Reference Product Manuals and Instructions For Use for complete instructions)
[light backgrounds]
[dark backgrounds]
fms duo + Q u i c k S e t u p G u i d e ®
( Using Irrigation Tube as "One Day Set"*)
[Black&White Only]
A. Connecting the One Day Set Irrigation Tube
1
a: Insert power cable into socket.
c
b: Attach the foot pedal connector to the port.
e FOOT PEDAL
b a
c: Attach shaver interface connector to the port. d: Insert power cable into interface cable.
SHAVER INTERFACE
f
g LAVAGE
e: Connect interface cable to shaver box.
CANN
ULA SU
d
CTION
f: Connect shaver to interface cable. g: Insert power cables into wall socket.
2
a
a
a: Remove One Day Set irrigation tube from the package and close three (3) white clamps on the One Day Set irrigation tube.
*"One Day Set" allows irrigation tubing to be used for up to eight hours.
a
b
+
®
N
T
IO IRR I
GA
Fluid management system with integrated shaver
PUMP ALARM
POWER STAND-BY
b: Place and center the tube around the roller. Pull on the tube and close the tension rocker arm against the tube.
+
High Med Cannula Suction
GA
Shaver Suction
Low Min
Fluid management system with integrated shaver
Run
Stop
IR R I
+
®
N
T
IO
P R E S S U R E
Fill Chamber
®
N
T
IO
PUMP
P
GA
Fluid management system with integrated shaver
IR RI
3
a: Lift lids and roller arm, then slide the green part of the tube into the auto-locking feature on the pump.
PUMP ALARM
POWER STAND-BY
PUMP
c: Position the pressure chamber in the holder.
POWER
P R E S S U R E
ALARM
STAND-BY
d: Twist cap off of the pressure transducer tube.
P R E S S U R E
Fill Chamber
High Med Cannula Suction
Low
Shaver Suction
Fill Chamber
Lavage
High Med Cannula Suction
Low
Shaver Suction
Pinch Valve
Run Min
c
Min
Stop PUMP
P Pinch Valve
Run
Stop PUMP
GR OUP
d
4
a
a: Connect the pressure transducer tube into the fill chamber port. Turn clockwise until snug.
b
+
®
Fluid management system with integrated shaver
Fill Chamber PUMP
b: Turn pump on by pressing I switch on back.
POWER
ALARM
STAND-BY
d GR OUP
c: Close lid and press POWER STAND-BY button.
P R E S S U R E
Fill Fill Chamber Chamber
UP
TYPE B CLASS I
d: Remove caps off irrigation spikes.
Med Low Min
Run Stop
GR
IP54
High Cannula Suction
Shaver Suction
c
PUMP
0197
120/230V~50-60Hz 500VA
INPUT POWER:
REPLACE FUSES AS MARKED
5
a: Insert spikes into irrigation bags.
+
®
Fluid management system with integrated shaver
b: Open two (2) clamps on One Day Set irrigation tubes.
+
®
PUMP
Fluid management system with integrated shaver
ALARM
POWER STAND-BY
P R E S S U R E
PUMP ALARM
POWER STAND-BY
c: Press RUN STOP button. Prime pump to fifty (50). Fill Fill Chamber Chamber
d: Press FILL CHAMBER button to pump fluid into the chamber. Repeat until fluid rises to indicator window (1/3 full).
Fill Fill Chamber Chamber
P R E S S U R E
Med Low
Shaver Suction
Min
High Med
Cannula Suction
UP
Shaver Suction
Low
Run Stop
GR O
Min
PUMP
Run Stop
UP GR
PUMP
d
c
a
e: Twist cap off One Day Set irrigation tube.
High Cannula Suction
b e
B. Connecting the Patient Set (with One-way Valve)
1
a
a: Pass the patient set tube labeled WASTE to the circulating nurse. Place ends of patient set tube marked SHAVER and OUTFLOW CANNULA on the sterile field.
SHAVER WASTE
OUTFLOW CANNULA
b
b: Remove the intermediary irrigation tube with one-way valve from kit and close the white clamp.
INFLOW
c
c: Tighten white-blue connector on the intermediary irrigation tube. +
®
N
T
IO IR R I
GA
Fluid management system with integrated shaver
PUMP POWER
ALARM
STAND-BY
2
a
a: Twist blue cap off the intermediary irrigation tube.
P R E S S U R E
Fill Chamber
High Cannula Suction
Med
Shaver Suction
Low Min
Run Stop
b: Connect the One Day Set irrigation tube to the intermediary irrigation tube with one-way valve by screwing the two blue connector ends together until snug.
PUMP
c: Open both clamps until fluid exits the tube. Close the clamp nearest the end of the tube after fluid is released and place in the sterile field.
INFLOW
c
b
3
+
TI
TI
ON
ON
ON
TI
Lavage
Lavage
Lavage
Pinch Valve
Pinch Valve
PUMP
C
c
b
TI
a
ON
a: Press the PINCH VALVE button. Pinch valve will shift to the left for five (5) seconds.
SU C
C
Fluid management system with integrated shaver
Pinch Valve
b: Push the left tube into the left pinch valve with both thumbs. Pinch valve will move back to the right after five (5) seconds.
SU C
SU
Lavage
TI
TI
ON
C
ON
Pinch Valve
c: Close the cover and place both patient set tubes behind the tube holder.
Lavage
Lavage
Pinch Valve
Pinch Valve
PUMP
A W
E ST
d: Place the tube marked WASTE into the waste collection bag.
d LLEC TI CO
O
grounds]
SU
®
SU
C
b: Place and center the tube around the roller. Pull on the tube and close the tension rocker arm against the tube. c: Push the right tube into the right pinch valve with both thumbs.
4
c
b
a
a: Lift roller arm, then slide the orange part of the tube into the auto-locking device on the pump.
a
INFLOW
5
a: Connect the tube marked INFLOW to the arthroscopic scope sheath.
b SHAVER
b: Connect the tube marked SHAVER to the arthroscopic shaver. c: Connect the tube marked OUTFLOW CANNULA to the suction or working cannula and open all clamps on the tubes.
c OUTFLOW CANNULA
a
C. Set up for next operation
1
a: If other surgeries are scheduled for the same operating day, disconnect the blue luer lock of the intermediary tubing and leave the one-way valve attached to the irrigation tubing at the end of each surgery.
a
2
a: At the start of a new surgery remove the old one-way valve. b: IMMEDIATELY connect the blue luer lock of the NEW patient set intermediary tubing with one-way valve to the blue luer lock of the One Day Set irrigation tubing. c: WARNING! Never attach a one-way valve to another.
b
c
Pinch Valve