DirectMed EasiLift Address: Phone: Email:
2/39 Gatwick Road, Bayswater North Victoria, 3153, Australia 1300 905 420 [email protected]
INTENDED USE In the event of a patient fall, The EasiLift patient lift system is used to raise the patient in a supine position from the floor to bed or stretcher height, utilizing the recommended air supply to inflate the EasiLift.
CONTRAINDICATIONS Patients who are experiencing thoracic, cervical, or lumbar fractures that are deemed unstable should not use the EasiLift system unless a clinical decision has been made by your facility. A spinal board can be used to stabilize the patient prior to raising with the EasiLift.
INTENDED CARE SETTINGS Hospitals, long term or extended care facilities
PRECAUTIONS *Make sure patient safety straps are secured before moving. *Never use patient safety straps to pull the EasiLift , as they may tear. *Move the EasiLift using the transport handles. *When moving a patient on the inflated EasiLift, use caution and move slowly. *Additional caregivers are recommended when moving a patient over 250Kgs *Never attempt to move a patient on an un-inflated EasiLift *Never leave a patient unattended on an inflated EasiLift *Use this product only for its intended purpose as described in this manual *Only use authorized attachments and accessories. *For safety, always use a minimum of two caregivers while using the EasiLift. *See product-specific user manuals for additional operating instructions.
PRECAUTIONS FOR AIR SUPPLY *Not for use in the presence of flammable anesthetics or in a hyperbaric chamber or oxygen tent *Route the power cord in a manner to ensure freedom from hazards *Avoid blocking the air intakes of the air supply *To avoid electric shock do not open the air supply
Part Identifications of the EasiLift
Instructions for Use 1. Place the EasiLift on the floor next to the patient, making sure the chamber with the inlet valve is closest to the floor 2. Ensure all four deflation valves are capped tightly 3. Log roll patient onto the deflated EasiLift and position patient with feet at the valve end where indicated. Loosely secure patient safety straps. Straps will tighten during inflation. 4. The patient can be placed on top of the EasiLift using an air transfer mattress
system. If a transfer mattress system is used, make sure that the air transfer mattress and patient are properly centered on the EasiLift. Always deflate the air transfer mattress prior to inflating the EasiLift. 5. Plug the air supply power cord into a 240vac electrical outlet. 6. Turn on the air supply to initiate air flow. 7. To begin inflation, hold hose nozzle firmly against inlet valve 8. When chamber 1 is fully inflated, the air will go into the second chamber automatically. The same process happens for chambers 3 and 4. DO NOT REMOVE HOSE UNTIL ALL 4 CHAMBERS ARE FULLY INFLATED! 9. When fully inflated, remove hose, valve will automatically close, keeping the EasiLift inflated 10. Turn off the air supply, and attach inlet valve cap before transferring 11. Do not lower the patient by deflating the EasiLift. The EasiLift will become unstable if any f the chambers are deflated.
PRODUCT SPECIFICATION Material
Main body material: Nylon Oxford
Construction
RF-Welded
width
32”(81cm) or 39” (99cm)
Length
72”(183cm) or 78” (198cm)
Height
30” (76cm) inflated, each chamber 19cm
Latex Free Weight Limit 1000Lbs (453kg)
Cleaning instructions In between patient uses, the EasiLift should be wiped down with a neutral detergent. Do not launder the EasiLift
PREVENTIVE MAINTENANCE The EasiLift should be periodically inspected to ensure the following: *All deflation valves are equipped with a cap *All caps are intact * All patient safety straps are attached *All buckles are intact and operational *Transfer handles are all attached and undamaged *Inlet valve is self-sealing with no evident air leakage *There are no punctures or tears
Warranty The EasiLift is warranted to be free from defects in materials and workmanship for a period of one (1) Year from the date of installation. In the unlikely event that a problem arises as a result of defective materials or workmanship, please contact your local supplier to arrange a repair or replacement.