Emprint

Emprint Ablation System

Emprint Alert Procedures Guide

Guide

2 Pages

Emprint Ablation System TM  ALERT PROCEDURES  WITH THERMOSPHERE  TM  TECHNOLOGY  Generator Reset Button RTP Temperature Display  Remote Temperature Probe Connector Port  High Efficiency Cable Connection Port  Power Controls  RTP Shutoff Enable Button  Treatment Time Controls  Alert Bank  Ablation START/STOP Button  Generator ON/OFF Button  Alert & Alarm  Cause  Remediation  Antenna Not Identified  Meaning: When an antenna is not properly connected this warning is activated. Generator Response: Generator will not start Microwave power.  Check connections between antenna and generator. Replace antenna if a secure connection doesn’t resolve alert state.  Meaning: Reflected power is unusually high. Generator Response: Microwave power delivery is disabled until the condition is resolved.  Indication that device was activated in the presence of air. Ensure antenna is placed in tissue before activation. If antenna is properly placed this may indicate antenna is damaged and should be replaced before proceeding. Clear the alarm by pressing RESET and continue the procedure.  Meaning: Internal Antenna temperature has exceeded limit. Generator Response: Microwave power is disabled until internal temperature drops below 45° C.  Ensure cooling system is turned on and saline flow is not obstructed. Clear the alarm by pressing RESET and continue the procedure.  Meaning: RTP shutoff feature was enabled and measured probe temperature has met or exceeded 45° C during ablation. Generator Response: Microwave power delivery is disabled.  When the measured probe temperature is below 45° C, clear the alarm by pressing RESET and continue the procedure.  Meaning: The generator has detected a fault. Generator Response: Power is disabled on this trip.  Restart generator. If issue persists, power off generator completely for 10 minutes. If issue persists after 10 minutes power off, consult Covidien sales and service department.  ?  +  Reflected Power Trip  + Antenna Temperature Limit Exceeded  + RTP Trip Alarm  + General Warning  + External Control  Meaning: External Control can only be accessed and activated by removing the EXTERNAL CONTROL PANEL and is for use by Covidien service personnel only.  Manual Operation  Meaning: The Manual Control function can only be accessed and activated by removing the cover on SERVICE PORT and is for use by Covidien service personnel only.  Switch is Closed  Meaning: The Switch Is Closed indicator illuminates while the START/STOP button or footswitch is actively being depressed.
File Type: PDF
File Size: 1.05 MB
File Name: Emprint - 1077537 - Emprint Alert Procedures Guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions