Liberty Starting Treament Procedure Card Rev A

Procedure Card

2 Pages

Select  • Check the package label on the Liberty cycler set to ensure it is not past its expiration date, and then remove the cycler set from its packaging.  Starting Treatment  This procedure is not intended to replace your doctor’s, practitioner’s, or peritoneal dialysis (PD) nurse’s advice or training. Refer to the Liberty® Select User’s Guide for detailed information including device description, instructions, contraindications, warnings, and precautions. As with all PD procedures, use aseptic technique. This information is provided for QUICK REFERENCE only.  Cassette   aution: Use caution when touching the cassette film to C prevent damage.  4  Note: All pictures are for example only.  • Turn on your cycler using the white power switch on the back of the cycler.  • Firmly push the door latch to open the cassette door.  5  Cassette Domes  - Liberty cycler set			  - Drain line(s) or drain bags  - stay•safe® organizer			  - Hand sanitizer  6  Cassette Catch  Caution: Do NOT force the door closed. If you’re having trouble closing the door, open the cassette door and make sure the cassette has been inserted correctly.  • Hold the cassette with the plastic domes facing outward (towards you). When directed:  • Then, snap the cassette in place using the cassette catch at the bottom of the pump module.  • Choose your heater bag volume (2L, 3L, 5L, 6L). •T  he bag you use must be at least 1000 mL larger than your first fill volume and at least as much as your maximum fill volume.  • Mask and wash hands. * Solution, Clarity, Amount, Leaks, Expiration Date  • Insert the blue stay•safe PIN connector into the stay•safe organizer clip below the control panel.  • Your cycler will pressurize the cassette door and then display the next step of the setup process (as pictured to the left).  • First, slide the cassette up and under the cassette guide pins. - stay•safe caps  • If using a nightstand, make sure the tubing is hanging down freely over the front of the nightstand.  • Gently close the cassette door. Ensure the cassette door clicks into place to lock it.  9  • Gather supplies:  480146 Liberty Procedure Card Rev A.indd 1  8  Warning: Check that the pump module is clean and free from obstructions before inserting the cassette. Keep fingers clear of moving parts.  Guide Pins  3  Cycler Cart Handle  Caution: The cassette door is pressurized. Do not attempt to open the cassette door until your machine instructs you to do so.  • Press OK to start treatment.  - Solution bags (Check S.C.A.L.E.)*  • If your cycler DOES NOT HAVE an alignment bar, the tubing should hang freely down in front of the cycler.  Caution: Avoid touching any of the sensors inside the cassette door, as this could cause damage to the pump module.  • Return to the Ready screen and make sure your prescription information is correct.  2  • If your cycler HAS an alignment bar, the tubing should hang down in front of the cycler over the alignment bar.  • If using a cycler cart, be sure the cycler tubing is hanging down behind the handle of the cart.  Warning: DO NOT USE the cassette if it is damaged. Call Customer Service at 800-323-5188 to arrange a pick-up to return the damaged set.  • If using the IQdriveTM, insert it into the USB port. When facing the front of the cycler, the USB port is located on the back left side.  • To make any changes to the therapy, patient, or hardware settings, press My Settings.  7  Alignment Bar  Warning: A damaged cassette can cause PD solution to leak into the cycler and is a potential risk for contamination. Notify your PD nurse if you find a fluid leak.  Tubing  • Make sure the cycler is plugged into a grounded outlet.  1  • Inspect the Liberty cycler set to make sure it is free from kinks or damage. Look for scratches, loose tubing, or small holes in the cassette film.  • Make sure the cassette is resting under the cassette guide pins at the top of the pump module and within the catch at the bottom of the pump module.  The cycler operates the same with or without an alignment bar. The same cassette insertion technique should be used for cyclers with or without an alignment bar.  10  Note: Place the solution bag with the largest volume on the heater tray.  9/11/2019 3:25:56 PM
File Type: PDF
File Size: 405 KB
File Name: Fresenius Medical - 480146 - Liberty Starting Treament Procedure Card Rev A - 2019-09.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions