Accessories Replacement Parts
5 Pages
Preview
Page 1
CARESCAPE Parameter Devices The purpose of this document is to describe the CARESCAPE Parameter device GE order part numbers, cable lengths, connection types, and field replacement unit (FRU) part numbers. Please refer to the CARESCAPE ONE User manual or OEM User manual for detailed information on specifications and usage of the devices.
CARESCAPE ECG Cable Lengths and Connection Types
1.8 m (FRU)
10 cm
GE Order Part Numbers
Field Replaceable Parts
2099884-001A1
2094688-011 FRU, Host Cable, Short, 1.8M CARESCAPE ECG
CARESCAPE ECG 1.8M AHA
1.9 m
2099884-001A3 3.6 m (FRU)
10 cm
CARESCAPE ECG 3.6M AHA
2094688-012 FRU, Host Cable, Long, 3.6M CARESCAPE ECG
3.7 m
2099884-001C1 1.8 m (FRU)
10 cm
CARESCAPE ECG 1.8M IEC
2094688-011 FRU, Host Cable, Short, 1.8M CARESCAPE ECG
1.9 m
2099884-001C3 3.6 m (FRU)
10 cm 3.7 m
gehealthcare.com
CARESCAPE ECG 3.6M IEC
2094688-012 FRU, Host Cable, Long, 3.6M CARESCAPE ECG
CARESCAPE SpO2 Cable Lengths and Connection Types
GE Order Part Numbers
Field Replaceable Parts
2097648-001 0.9 m
12 cm
0.8 m
1.8 m
CARESCAPE SPO2 TRUSIGNAL 1.8M
No FRU available
2097648-002 0.9 m
12 cm
2.0 m
3m
CARESCAPE SPO2 TRUSIGNAL 3M
No FRU available
2082747-001 0.3 m
12 cm
0.8 m
1.2 m
CARESCAPE SPO2 NELLCOR 1.2M (will be supplied until stock remains)*
No FRU available
2082747-001 0.9 m
12 cm
0.8 m
1.8 m
CARESCAPE SPO2 NELLCOR 1.8M*
No FRU available
2082747-002 0.9 m
12 cm
2.0 m
3m
0.9 m (FRU)
14 cm
CARESCAPE SPO2 NELLCOR 3M*
No FRU available
2103987-002
2094693-007 FRU CARESCAPE SPO2 MASIMO HOST CABLE 0.9M
CARESCAPE SPO2 MASIMO 0.9M*
1.0 m
2103987-001 1.8 m (FRU)
14 cm 1.9 m
* Indicates OEM CARESCAPE Parameter 2 of 5
CARESCAPE Parameter Guide
CARESCAPE SPO2 MASIMO 1.8M*
2094693-006 FRU CARESCAPE SPO2 MASIMO HOST CABLE 1.8M
INVASIVE PRESSURE
PRES
0.9 m
12 cm
0.8 m (FRU)
GE Order Part Numbers
Field Replaceable Parts
2099660-001E1
2094690-007 FRU, CARESCAPE ONE Interface Cable, Pressure Edwards Dual 0.8M
CARESCAPE PRESSURE EDWARDS DUAL 1.8M
1.8 m
2099660-001E3
PRES
0.9 m
12 cm
2.6 m (FRU)
CARESCAPE PRESSURE EDWARDS DUAL 3.6M
3.6 m
2099660-001U1
PRES
0.9 m
12 cm
0.8 m (FRU) 1.8 m
2099660-001U3
PRES
0.9 m
12 cm
2.6 m (FRU) 3.6 m
12 cm
0.8 m (FRU) 1.8 m
12 cm
2.6 (FRU) 3.6 m
12 cm
0.8 m (FRU) 1.8 m
12 cm
2.6 m (FRU) 3.6 m
12 cm
0.3 m 1.2 m
3 of 5
CARESCAPE Parameter Guide
CARESCAPE PRESSURE ARGON DUAL 3.6M
2099660-001N
PRES
0.9 m
CARESCAPE PRESSURE ARGON DUAL 1.8M
2099660-001A3
PRES
0.9 m
CARESCAPE PRESSURE ICU DUAL 3.6M
2099660-001A1
PRES
0.9 m
CARESCAPE PRESSURE ICU DUAL 1.8M
2099660-001C3
PRES
0.9 m
CARESCAPE PRESSURE UTAH DUAL 3.6M
2099660-001C1
PRES
0.9 m
CARESCAPE PRESSURE UTAH DUAL 1.8M
CARESCAPE PRESSURE DUAL ADAPTER 1.2M
2094690-008 FRU, CARESCAPE ONE Interface Cable, Pressure Edwards Dual 2.6M
2094690–003 FRU, CARESCAPE ONE Interface Cable, Pressure Utah Dual 0.8M
2094690–004 FRU, CARESCAPE ONE Interface Cable, Pressure Utah Dual 2.6M
2094690–005 FRU, CARESCAPE ONE Interface Cable, Pressure ICU Dual 0.8M
2094690–006 FRU, CARESCAPE ONE Interface Cable, Pressure ICU Medical Dual 2.6M
2094690–001 FRU, CARESCAPE ONE Interface Cable, Pressure Argon Dual 0.8M
2094690–002 FRU, CARESCAPE ONE Interface Cable, Pressure Argon Dual 2.6M
2094690–010 FRU, CARESCAPE Pressure Parameter Cable Adapter 0.3M
CARESCAPE Temperature Cable Lenghts and Connection Types
0.9 m
12 cm
0.5 m (FRU) 1.5 m
GE Order Part Numbers
Field Replaceable Parts
2099661-001A
2094689-001 FRU, CARESCAPE ONE Interface Cable, Temperature, Dual 0.5M
CARESCAPE TEMPERATURE DUAL REUSABLE 2099661-001D1
0.9 m
12 cm
0.5 m (FRU) 1.5 m
CARESCAPE TEMPERATURE DUAL DISPOSABLE 1.5M 2099661-001D3
0.9 m
12 cm
2.0 m (FRU) 3m
CARESCAPE CO2 Cable Lengths and Connection Types
2094689-002 FRU, CARESCAPE ONE Interface Cable, Temperature, Disposable, Dual, Short 0.5M
CARESCAPE TEMPERATURE DUAL DISPOSABLE 3M
2094689-003 FRU, CARESCAPE ONE Interface Cable, Temperature, Disposable, Dual, Long 2.0M
GE Order Part Numbers
Field Replaceable Parts
2099061-001 0.9 m
12 cm 3m
2.0 m
CARESCAPE CO2 - LOFLO 3M*
No FRU Available
PMC40M-GE CARESCAPE CO2 – MICROSTREAM 1.2M*
No FRU Available
GE Order Part Numbers
Field Replaceable Parts
1.2 m
CARESCAPE rSO2 Regional Oximetry
PMC71V-GE CARESCAPE rSO2 – INVOS 4.3M*
No FRU Available
4.3 m
PMAC71RSC INVOS Reusable Sensor Cable* 1.6 m
* Indicates OEM CARESCAPE Parameter 4 of 5
CARESCAPE Parameter Guide
No FRU Available
Product may not be available in all countries and regions. Full product technical specification is available upon request. Contact a GE Healthcare Representative for more information. Please visit www.gehealthcare.com/promotional-locations. Data subject to change. © 2022 GE GE and the GE monogram are trademarks of GE. All other trademarks are property of their respective owners. Reproduction in any form is forbidden without prior written permission from GE. Nothing in this material should be used to diagnose or treat any disease or condition. Readers must consult a healthcare professional. JB20054XX.1 6/2022