GE Healthcare
LOGIQ E10s Basic User Manual Rev 2 May 2021
Basic User Manual
1472 Pages
Preview
Page 1
Technical Publications 5860662-1EN Rev. 2 LOGIQ™ E10s Basic User Manual Version R3
Operating Documentation Copyright 2021 By General Electric Co.
Regulatory Requirement LOGIQ E10s complies with regulatory requirements of the following European Regulation 2017/745 EU concerning medical devices.
First CE Marked in 2021. This Basic User Manual is a reference for the LOGIQ E10s. It applies to Version R3 software for the LOGIQ E10s ultrasound system.
GE Healthcare P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A. (Asia, Pacific, Latin America, North America) GE Healthcare GmbH Beethovenstrasse 239 Postfach 11 05 60 D-42655 Solingen GERMANY TEL: 49 212.28.02.208; FAX: 49 212.28.02.380
Revision History Reason for Change DATE (YYYY/MM/DD)
REV Rev. 2
2021/05/21
REASON FOR CHANGE Initial Release
List of Effective Pages
PAGE NUMBER
REVISION NUMBER
PAGE NUMBER
REVISION NUMBER
Title Page
Rev. 2
Chapter 6
Rev. 2
Revision History
Rev. 2
Chapter 7
Rev. 2
Regulatory Requirements
Rev. 2
Chapter 8
Rev. 2
Table of Contents
Rev. 2
Chapter 9
Rev. 2
Chapter 1
Rev. 2
Chapter 10
Rev. 2
Chapter 2
Rev. 2
Chapter 11
Rev. 2
Chapter 3
Rev. 2
Chapter 12
Rev. 2
Chapter 4
Rev. 2
Chapter 13
Rev. 2
Chapter 5
Rev. 2
Index
Rev. 2
Please verify that you are using the latest revision of this document. Information pertaining to this document is maintained on MyWorkshop. If you need to know the latest revision, contact your distributor, local GE Sales Representative or in the USA call the GE Ultrasound Clinical Answer Center at 1 800 682 5327 or 1 262 524 5698.
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-1
Regulatory Requirements
Conformance Standards The following classifications are in accordance with the IEC/ EN 60601-1:6.8.1: •
According to 2017/745 EU Medical Device Regulations, this is Class IIa Medical Device.
•
According to IEC/EN 60601-1, •
•
Equipment is Class I, Type B with BF or CF Applied Parts.
According to CISPR 11, •
Equipment is Group 1, Class A ISM Equipment.
This product complies with the regulatory requirement of the following: •
The LOGIQ E10s console and related probes are an Active Diagnostic Medical Product belonging to Class IIa according to the MDR - REGULATION (EU) 2017/745 for use on human patients.
•
Medical Device Regulation (EU) 2017/745: the CE label affixed to the product testifies compliance to the Regulation. The location of the CE marking is shown in the Safety chapter of this manual. Authorized EU Representative European registered place of business: GE Medical Systems SCS 283 rue de la Minière 78530 BUC, France
i-2
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Conformance Standards (continued) •
•
International Electrotechnical Commission (IEC). •
IEC/EN 60601-1 Medical Electrical Equipment, Part 1 General Requirements for Safety.
•
IEC/EN 60601-1-2 Electromagnetic disturbances Requirements and tests.
•
IEC 60601-1-6 (Usability), EN 1041 (Information supplied with medical devices)
•
IEC 60601-2-37 Medical electrical equipment. Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment.
International Organization of Standards (ISO) •
•
ISO 10993-1 Biological evaluation of medical devices.
Underwriters’ Laboratories, Inc. (UL), an independent testing laboratory. •
UL 60601-1 Medical Electrical Equipment, Part 1 General Requirements for Safety.
•
ANSI/AAMI ES60601-1:2005/(R)2012 Medical electrical equipment -Part 1: General requirements for basic safety and essential performance
•
Canadian Standards Association (CSA). •
CSA 22.2, 60601-1 Medical Electrical Equipment, Part 1 General Requirements for Safety.
•
Medical Device Good Manufacturing Practice Manual issued by the FDA (Food and Drug Administration, Department of Health, USA).
•
EN/ISO 15223-1 Medical devices -- Symbols to be used with medical device labels, labelling and information to be supplied -- Part 1: General requirements
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-3
Certifications •
General Electric Medical Systems is ISO 13485 certified.
Original Documentation •
The original document was written in English.
Importer Information •
i-4
Turkey
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Table of Contents
Conformance Standards - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i-2 Certifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i-4 Original Documentation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i-4 Importer Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i-4
Table of Contents Chapter 1 - Introduction System Overview Attention - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 Documentation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-3 Principles of Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-9 Indications for Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-10 Contraindication - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-11 Prescription Device - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-11 Clinical Benefit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-11 Patient Population- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-11
Contact Information Contacting GE Ultrasound - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-12 Manufacturer - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-17
Chapter 2 - Safety Owner Responsibility Owner requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Notice against user modification- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Reporting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-3
Safety Precautions Precaution Levels - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-4 Hazard Symbols - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-5 Patient Safety- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-7 Equipment and Personnel Safety - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-11 Classifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-18 EMC (Electromagnetic Compatibility) - - - - - - - - - - - - - - - - - - - - - - - - 2-19 Patient Environmental Devices- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-38 Acoustic Output - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-40 RoHS LOGIQ E10s Hazardous Substances - - - - - - - - - - - - - - - - - - - 2-44 WEEE Passport - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-46 Safe Product and Packaging Disposal - - - - - - - - - - - - - - - - - - - - - - - 2-46
Device Labels Label Icon Description- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-47 CE mark statement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-55 Probe Labeling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-56
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-5
Chapter 3 - Preparing the System for Use Site Requirements Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-2 Before the system arrives - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-3 Environmental Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-4
Console Overview Console Graphics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-6 Peripheral/Accessory Connection- - - - - - - - - - - - - - - - - - - - - - - - - - - 3-11
Powering the System Connecting the System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-19 Circuit breaker - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-21 Power On - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-22 Power Off- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-37
System Language Configuration Select the System Language and Date/Time Format - - - - - - - - - - - - - 3-40
Connecting the Probe Connecting the Probe - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-43 Cable Handling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-45 Probe Management - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-45 Selecting probes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-46 Deactivating the Probe - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-47 Disconnecting the Probe - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-47 Storing the Probe - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-48 Storage/Transportation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-48
Operator Controls Control Panel Map - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-49 Operator Panel Movement Controls - - - - - - - - - - - - - - - - - - - - - - - - - 3-50 Keyboard - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-53 Touch Panel- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-54 Mode, Display and Print - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-56 Measurement and Annotation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-57
Monitor Adjusting the Monitor Position - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-58 Locking/unlocking the Monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-60 Adjusting the Monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-61 Wide Screen Monitor Display Settings - - - - - - - - - - - - - - - - - - - - - - - 3-63 Test Patterns - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-67
Monitor Display Monitor Display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-69 Monitor Display Layout - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-71 Using the Monitor Display Controls to Manage Images- - - - - - - - - - - - 3-76
System Positioning/Transporting Moving the System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-77 Wheels - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-81 Transporting the System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-84 Acclimation Time - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-85
i-6
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Chapter 4 - Preparing for an Exam Beginning an Exam Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-2 Patient Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3 OB Exam - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7
Starting an examination Cautions and Warnings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10 Creating a new patient record - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-12 Perform an exam - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-13 Ending an exam - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-14 Scanning without entering any patient data - - - - - - - - - - - - - - - - - - - - 4-14 Starting a new exam on an existing patient - - - - - - - - - - - - - - - - - - - - 4-15 Retrieve Patient/Exam Information from Worklist - - - - - - - - - - - - - - - - 4-16 Sending Multiple Exams and Patients with Single Click to PACS- - - - - 4-17 Change Patient Information except Patient ID and scan - - - - - - - - - - 4-17 Change Patient ID of the existing patient (Edit & Copy) - - - - - - - - - - - 4-18
Retrieving and editing archived information Searching for an existing patient - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-21 Changing Patient Information or an Exam - - - - - - - - - - - - - - - - - - - - - 4-24 Deleting the existing patient/exam/image - - - - - - - - - - - - - - - - - - - - - 4-25
MyPreset Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-27 Activating MyPreset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-27 Arranging MyPreset Tab - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-29
Chapter 5 - Optimizing the Image Optimizing B-Mode Intended Uses - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-2 B-Mode Scanning Hints- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3 B-Mode Controls- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-4 Auto Optimize - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-8 Continuous Tissue Optimization (CTO) - - - - - - - - - - - - - - - - - - - - - - - - 5-9 SRI-HD (High Detection Speckle Reduction Imaging)- - - - - - - - - - - - - 5-10 CrossXBeam - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-13 B-Flow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-14 LOGIQView - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-18 B Steer+ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-20 Touch TGC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-21 Speed of Sound (SoS) Tissue Imaging - - - - - - - - - - - - - - - - - - - - - - - 5-23 Minimizing Grating Lobe/Side Lobe Artifacts - - - - - - - - - - - - - - - - - - - 5-24
Optimizing M-Mode Intended Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-26 Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-26 Typical exam protocol - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-27 M-Mode Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-27 Anatomical M-Mode (AMM) and Anatomical Color M-Mode (ACMM) - - 5-28
Optimizing Color Flow Intended Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-7
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-30 Activating Color Flow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-31 Color Flow Mode Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-31 Radiantflow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-34 Flow Model Shortcuts - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-35 Power Doppler Imaging (PDI) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-38
Optimizing M Color Flow M Color Flow Mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-42
Optimizing Spectral Doppler Intended Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-43 Spectral Doppler Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-45 PW Doppler Mode Display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-46 Doppler Mode Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-47
Using 3D Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-51 3D Acquisition - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-52 3D Acquisition Parameter Description- - - - - - - - - - - - - - - - - - - - - - - - 5-54 Manipulating the Volume of Interest - - - - - - - - - - - - - - - - - - - - - - - - - 5-56 Easy 3D- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-58 Advanced 3D - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-60 Movie 3D - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-63 Tru3D and Volume Measurement - - - - - - - - - - - - - - - - - - - - - - - - - - 5-64
Chapter 6 - Scanning/Display Functions Freezing an Image Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-2 Freezing an image - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-2
Using CINE Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-3 Using CINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-5 Mark CINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-7 Preview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-8 Background Store - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-8 Image Storage Hints - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-9 Cine Capture - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-10
Image Zoom Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-14 HD Zoom - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-15 Pan Zoom - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-16 Magnification Zoom- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-17
Split Screen Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-18 Dual screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-18 Quad screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-19 Simultaneous mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-19 Dual Caliper - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-19
Annotating an Image Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-23
i-8
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Adding Comments to an Image - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-25 Body Patterns- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-35
Using the Fast Key Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-44 Create a Fast Key - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-44 Start a Fast Key - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-45 Backup and Restore the Fast Key - - - - - - - - - - - - - - - - - - - - - - - - - - 6-45
Chapter 7 - General Measurements and Calculations Introduction Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-2 Basic Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-3 Measurement Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-6 Touch Panel- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-7 Exam category/Study/Measurement - - - - - - - - - - - - - - - - - - - - - - - - - 7-11 General Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-12 Measurement Cursor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-14 Copy, move and paste measurement tools - - - - - - - - - - - - - - - - - - - - 7-15 Performing Measurements on Saved Images - - - - - - - - - - - - - - - - - - 7-16
Generic Measurements Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-18 B-Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-19 M-Mode Measurements- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-29 Doppler Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-32 Helpful hints - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-37
Mode Measurements B-Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-38 Doppler Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-45 M-Mode Measurements- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-56
Worksheet Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-58 To view a worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-59 To edit a worksheet- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-60 Recording Worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-64 OB Worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-65 Vascular Worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-67
Anatomical Survey Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-71 Editing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-72
Measurement and Calculation Setup Starting Study and Measurement Setup - - - - - - - - - - - - - - - - - - - - - - 7-75 Display/hide a folder or a measurement in the Touch Panel - - - - - - - - 7-80 Setting up an automatic measurement flow - - - - - - - - - - - - - - - - - - - - 7-85 Change the tool used to make a measurement - - - - - - - - - - - - - - - - - 7-86 Adding Folders and Measurements - - - - - - - - - - - - - - - - - - - - - - - - - 7-87 M & A Advanced Preset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-100 Doppler tab - Modify Calculation- - - - - - - - - - - - - - - - - - - - - - - - - - - 7-105 Application Measurement Preset - - - - - - - - - - - - - - - - - - - - - - - - - - 7-106
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-9
Chapter 8 - Application M&A General Information Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-2 General Guidelines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-2
Abdomen Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-3
Small Parts B-Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-4
OB Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-6 OB Type change- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-7 To Start an Obstetrics Exam - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-8 OB Measurements Performed Over Multiple Planes- - - - - - - - - - - - - - 8-12 OB Calculation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-15 OB Graphs- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-17 OB-Multigestational- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-26 OB Table Editor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-28
GYN Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-42 B-Mode Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-42
Cardiac Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-45 Naming Format for Cardiac Measurements - - - - - - - - - - - - - - - - - - - - 8-45 Cardiac Doppler Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-49
Vascular Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-50 IMT Measurement- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-55 Auto Vascular Calculation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-65 Manual Vascular Calculation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-69 Intravessel ratio - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-70 Bypass Graft Anastomosis Graph - - - - - - - - - - - - - - - - - - - - - - - - - - 8-72
Urology Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-75 Bladder Volume - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-75 Renal Volume- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-76 Prostate Volume - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-76 Pelvic Floor Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-78
Pediatrics Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-81 Pediatrics Hip - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8-82
Chapter 9 - Recording images Getting Set Up to Record Images Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-2 Image Management Guide - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-4 Adding Devices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-5 Adding a Dataflow- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-5 Adding Devices to a Print Button - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-5
i-10
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Formatting Removable Media - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-5
Storing Images and Cineloops Storing an image - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-6 Storing a cine loop - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-7
Review images in archive Review the patient exam/image - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-10 Active Images- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-11 Image Reorder - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-13 Image History - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-15
Clipboard Clipboard icon - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-17 Saving the image /cine to the Clipboard - - - - - - - - - - - - - - - - - - - - - - 9-17 Previewing Clipboard Images- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-18 Recalling Images from the Clipboard - - - - - - - - - - - - - - - - - - - - - - - - 9-18 To delete an image from the clipboard - - - - - - - - - - - - - - - - - - - - - - - 9-18
Save As Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-19 SaveAs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-19 ’SaveAs’ Images- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-23 Notes on Transfer to CD/DVD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-24 Storing Images with More Resolution - - - - - - - - - - - - - - - - - - - - - - - - 9-24
EZBackup Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-25 Perform EZBackup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-28 To Review EZBacked Up Images - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-31
Data Transfer Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-32 Export/Import - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-32 Worklist (Search and retrieve the Patient/Exam information) - - - - - - - - 9-36 MPEGvue - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-37
External drives Intended Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-43 DVD Drive - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-44 USB Hard Disk Drive and USB Flash Drive - - - - - - - - - - - - - - - - - - - - 9-46 USB Quick Save- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-52
Printing Options Setting up Digital Peripherals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-53 External Paper Printer - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9-61
Portable Exam Perform a Portable Exam (Using the Worklist) - - - - - - - - - - - - - - - - - 9-65
Chapter 10 - Customizing Your System Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-2
System Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-6 Changing system parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-7 System/General Preset Menu - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-8
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-11
System/System Display Preset Menu - - - - - - - - - - - - - - - - - - - - - - - 10-12 System/System Imaging Preset Menu - - - - - - - - - - - - - - - - - - - - - - 10-15 System/System Measure Preset Menu - - - - - - - - - - - - - - - - - - - - - - 10-18 System Backup and Restore Preset Menu - - - - - - - - - - - - - - - - - - - 10-21 System/Peripherals Preset Menu - - - - - - - - - - - - - - - - - - - - - - - - - - 10-23 System/User Configurable Key - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-25 System/About Preset Menu - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-28 Licenses - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-28
Imaging Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-29 Changing imaging presets - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-30 General - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-30
Comments Libraries Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-32 Comments Libraries/Libraries Preset Menu - - - - - - - - - - - - - - - - - - - 10-32 Comments Libraries/Comments Preset Menu - - - - - - - - - - - - - - - - - 10-35 Comments Libraries/Applications Preset Menu - - - - - - - - - - - - - - - - 10-36 Comments Libraries/Mapping Preset Menu - - - - - - - - - - - - - - - - - - - 10-38
Body Patterns Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-41 Body Pattern Libraries/Libraries Preset Menu - - - - - - - - - - - - - - - - - 10-41 Body Pattern Libraries/Body Patterns Preset Menu - - - - - - - - - - - - - 10-43 Body Pattern Libraries/Applications Preset Menu- - - - - - - - - - - - - - - 10-44
Application Presets Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-46
User Specific Test Patterns 3D/4D Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-54 4D Presets - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-54
Configuring Connectivity Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-59 Connectivity Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-59 TCP/IP- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-61 Device - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-66 Service - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-69 Dataflow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-84 Button - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-85 Removable Media- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-87 Miscellaneous - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-89 Tricefy Activation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-93 Koios DS Configuration (not available in all countries) - - - - - - - - - - - 10-94 Device Mgmt Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-97
Measure Reports System Administration Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-104
i-12
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Administrator Tasks - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-105 Privacy and Security - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-105 System Admin - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-113 Users- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-116 Logon - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-117 Groups - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-130 System Password - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-133 Disk Encryption - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-134 Audit Report and System Log Server Configuration - - - - - - - - - - - - 10-142
Imaging Preset Manager Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-145 Creating a User-Defined Application Preset- - - - - - - - - - - - - - - - - - 10-145 Sharing User Presets between LOGIQ E10s Systems - - - - - - - - - - 10-150 Retain Field of View - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-151
Backup and Restore Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-152
Search Utility Parameter Search - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-156
Chapter 11 - Probes and Biopsy Probe Overview Ergonomics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-2 Supported Probes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-2 Probe orientation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-11 Probe Naming Conventions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-11
Probe Safety Care and Handling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-12 Handling precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-13 Electrical shock hazard - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-14 Special handling instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-15 Probe handling and infection control - - - - - - - - - - - - - - - - - - - - - - - - 11-17
Care and Maintenance Inspecting probes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-18 Probe Reprocessing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-19 Probe Cleaning and Disinfecting Notes - - - - - - - - - - - - - - - - - - - - - - 11-38 Probe Disinfectants - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-41 Coupling Gels- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-45 V Nav Cleaning Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-48 Planned Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-49 Automatic Probe Diagnostics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-49 Probe Care Cards- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-50 Returning/Shipping Probes and Repair Parts- - - - - - - - - - - - - - - - - - 11-51
Biopsy Special Concerns Precautions Concerning the Use of Biopsy Procedures - - - - - - - - - - 11-52 Biopsy Guide Sterilization - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-54
Performing a Biopsy Displaying the Guidezone - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-55 Preparing the Biopsy Guide Attachment - - - - - - - - - - - - - - - - - - - - - 11-60
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-13
4D Probe Biopsy Needle Path Selection - - - - - - - - - - - - - - - - - - - - - 11-80 Biopsy Needle Path Verification - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-80 The Biopsy Procedure- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-81 Post Biopsy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-82 Probe Biopsy Reprocessing- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11-83
Surgery/Intra-operative Use Preparing for Surgery/Intra-operative Procedures - - - - - - - - - - - - - - 11-85
Chapter 12 - User Maintenance System Data Features/Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-2 Clinical Measurement Accuracy - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-7
Privacy and Security Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-14 Privacy & Security Environment - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-14 Identity Provisioning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-15 Network Infrastructure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-16
Anti-Virus Software Note LOGIQ E10s Security - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-17
Loading Windows Patches Loading a Windows Patch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-20 Performing Software Patch Verification - - - - - - - - - - - - - - - - - - - - - - 12-21 Patch Installation Notes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-24 Reloading Software- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-24
Software Download Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-25
Base Image and Software Load Base Image and Software Load Procedure - - - - - - - - - - - - - - - - - - - 12-30
Copyrighted Material Viewing Copyrighted Third Party Software License Information - - - - - 12-31
System Care and Maintenance Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-32 Maintenance Schedule - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-33 Cleaning and Disinfecting the System- - - - - - - - - - - - - - - - - - - - - - - 12-34 Other Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-44
Quality Assurance Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-50 Typical Tests to Perform - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-51 Baselines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-53 Periodic Checks - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-53 Results - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-54 System Setup- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-54 Test Procedures - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-55 Setting up a Record Keeping System - - - - - - - - - - - - - - - - - - - - - - - 12-64 Ultrasound Quality Assurance Checklist - - - - - - - - - - - - - - - - - - - - - 12-65
Image Quality Check Image Quality Check (IQC) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-66
i-14
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Assistance Supplies/Accessories - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12-67
Chapter 13 - Advanced Features List of Advanced Features Table of Contents - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-2
Using 4D 4D Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-4 Features supported with 4D - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-4 4D Principles of Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-5 4D Operational Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-14 4D Presets - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-16 Performing a 4D Scan - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-17 Tomographic Ultrasound Imaging (TUI) - - - - - - - - - - - - - - - - - - - - - 13-40 SonoRenderlive - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-44 OmniView - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-46 STIC (Spatio-Temporal Image Correlation) - - - - - - - - - - - - - - - - - - - 13-50
Contrast Imaging Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-54 Contrast Imaging Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-55 Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-57 Contrast MVI Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-57 Contrast Presets- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-58 Sonazoid™ Contrast Agent - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-58 Contrast Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-59 Static 3D with Contrast - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-64 Time Intensity Curve (TIC) Analysis - - - - - - - - - - - - - - - - - - - - - - - - 13-66 Parametric Imaging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-96
Strain Elastography Description- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-111 Using Strain Elastography - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-112 Clinical Applications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-114 Strain Elastography Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-114 Application Parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-116 General Imaging Parameters by Application/Probe/Feature - - - - - - 13-116
Elastography Analysis Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-117 Using Elastography Analysis - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-117 Elastography Analysis Display Description - - - - - - - - - - - - - - - - - - 13-120 Additional Notes for Elastography Analysis - - - - - - - - - - - - - - - - - - 13-121
Shear Wave Elastography Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-122 Intended Uses - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-124 Configuring Shear Wave - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-124 Activating Shear Wave - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-128 Shear Wave Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-129 Shear Wave Touch Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-135 Using Shear Wave (SW) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-140
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-15
Typical Exam Protocol (Liver) - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-141 Shear Wave Measurements- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-143 Scanning Hints - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-151
Ultrasound-Guided Attenuation Parameter (UGAP) Option Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-152 Activation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-153 Measurement and Worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-154 2D Color Map - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-157
Continuous Wave Doppler (CWD) Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-158 Steerable - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-158 Non-Imaging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-158 Activating CW Doppler - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-159 Exiting CW Doppler- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-159
Tissue Velocity Imaging (TVI) Intended Use - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-160 Activating TVI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-160 Optimizing TVI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-161 TVI and TVD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-162
Quantitative Analysis (QAnalysis) Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-163 Quantitative Flow Analysis- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-163 Selecting QAnalysis Image Range - - - - - - - - - - - - - - - - - - - - - - - - 13-169 Activating QAnalysis - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-169 Common QAnalysis Function- - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-170
Stress Echo Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-183 Getting started with a stress study - - - - - - - - - - - - - - - - - - - - - - - - 13-184 Image acquisition - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-187 Continuous Capture mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-193 Analysis - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-205 Editing/Creating template - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-209 Wall Motion Segment Setup - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-216 Utility Application Settings for Protocol - - - - - - - - - - - - - - - - - - - - - 13-216 Report - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-217
Cardiac Automated Functional Imaging (Cardiac Strain) Cardiac Strain - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-219
Auto EF Auto EF Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-243 Acquisition - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-244 Starting AutoEF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-245 Defining the endocardial border (EB) - - - - - - - - - - - - - - - - - - - - - - 13-245 Selecting “Recalc”- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-245 Defining Endocardial Border (EB) in semi-automatic 3 Point mode - 13-246 Editing the endocardial border trace - - - - - - - - - - - - - - - - - - - - - - - 13-247 EF results screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-249 Tracking Validation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-251 Possible causes of poor tracking - - - - - - - - - - - - - - - - - - - - - - - - - 13-252
i-16
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
Results - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-253 Exit AutoEF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-254
ECG Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-255 ECG Cable/Respiration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-257 Physiological Trace Monitor Display - - - - - - - - - - - - - - - - - - - - - - - 13-258 ECG Touch Panel- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-259
Volume Navigation Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-261 Load the Volume Dataset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-266 Query/Retrieve - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-267 Setting Up V Nav sensors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-275 Activate V-Nav - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-279 Using V-Nav- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-285 Perform the registration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-287 Advanced GPS Markers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-301 V Nav Trackers- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-310
Breast Productivity Package Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-322 Breast Lesion M&A - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-322 Breast Measure Assistant (Auto Contour) - - - - - - - - - - - - - - - - - - - 13-325 Breast Assistant, Powered by Koios DS (not available in all countries) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-326
Thyroid Productivity Package Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-328 Worksheet and Summary Worksheets - - - - - - - - - - - - - - - - - - - - - 13-332 Thyroid Assistant, Powered by Koios DS (not available in all countries) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-333
Start Assistant Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-335 Start Assistant Mapping Editor - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-337
Scan Assistant Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-340 Scan Assistant Definitions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-341 Scan Assistant Description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-342 Setting up Scan Assistant - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-343 Using Scan Assistant - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-345 Exporting Scan Assistant Programs to Another LOGIQ E10s - - - - - 13-349 Scan Assistant Creator - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-350
Compare Assistant Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-378 Workflow example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-380 Setting Up Compare Assistant - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-381
OB Measure Assistant Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-389
Hepatic Assistant Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-391
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2
i-17
Activate Hepatic Assistant - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-392 Visualization- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-394
EZ Imaging Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-398 Activate EZ Touch Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-398 Quick Patient Change - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-405
Anonymize the patient Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-406 Anonymize the patient- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-407
Report Writer Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-408 Creating a report- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-409 Activating the Report- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-410 Editing a Report - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-414 Accessing Worksheet, OB Graph and Anatomical Survey Pages - - 13-427 Storing the Report- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-427 Retrieving an Archived Report - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-427 Deleting a Report from Archive - - - - - - - - - - - - - - - - - - - - - - - - - - 13-428 Printing the Report - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-428 Exporting the Report to Media - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-429 Exiting the report - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-429 Designing Your Own Template- - - - - - - - - - - - - - - - - - - - - - - - - - - 13-430 Direct Report - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-455 Report Presets - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-459
Configuring DICOM Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-465 Step 1 - Set up the Network Addresses for the LOGIQ E10s - - - - - 13-466 Step 2 - Set up the PACS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-467 Step 3 - Set up the DICOM Services for the Device - - - - - - - - - - - - 13-468 Step 4 - Set Up a Typical Dataflow - - - - - - - - - - - - - - - - - - - - - - - - 13-471 Step 5 - Set up the Print Keys - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-473 DICOM Job Spooler - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-476 Patient Menu DICOM Functionality- - - - - - - - - - - - - - - - - - - - - - - - 13-477 Troubleshooting DICOM Connectivity Issues- - - - - - - - - - - - - - - - - 13-478
Configuring the Wireless Network Wireless LAN (WLAN)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-479 Wireless LAN (WLAN) Specifications - - - - - - - - - - - - - - - - - - - - - - 13-480 Connecting to the WLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-482 Network and Spooler Status Icons - - - - - - - - - - - - - - - - - - - - - - - - 13-483 Adding a Wireless Network - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-484 Removing a WLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-485 Customizing Wireless Network Settings - - - - - - - - - - - - - - - - - - - - 13-486 Setting an IP Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-487 Refreshing a WLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-488 Managing Connectivity to a Wireless Network - - - - - - - - - - - - - - - - 13-488 Monitoring the WLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-488 WLAN Diagnostics - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-489 Repairing the WLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13-489
i-18
LOGIQ E10s – Basic User Manual 5860662-1EN Rev. 2