GE Healthcare
MAC 2000 Supplies and Accessories Guide Rev D Jan 2014
Supplies and Accessories Guide
26 Pages
Preview
Page 1
GE Healthcare
MAC™2000 ECG Analysis System Supplies and Accessories Reference Guide 2053535-004 Revision D
English © 2013-2014 General Electric Company. All Rights Reserved.
Publication Information The information in this manual applies only to MAC™2000. Due to continuing product innovation, specifications in this manual are subject to change without notice. MAC is a trademark owned by GE Medical Systems Information Technologies, Inc., a General Electric Company going to market as GE Healthcare. All other trademarks contained herein are the property of their respective owners. This product complies with the requirements concerning medical devices from the following regulatory bodies:
The document part number and revision are on each page of the document. The revision identifies the document’s update level. The revision history of this document is summarized in the following table. Revision
Date
Comments
A
17 October 2012
Internal release
B
19 April 2013
Customer release
C
19 August 2013
All references to the software version number were removed from the manual per SPR HCSDM00229788.
D
31 January 2014
Added CE mark information to Publication Information and on back page; added sentence in Chapter 2, Supplies & Accessories, noting that CE information is on individual item packaging and labeling: per SPR HCSDM00264047.
To access other GE Healthcare Diagnostic Cardiology manuals, go to the Common Documentation Library (CDL), located at www.gehealthcare.com/documents, and click Cardiology. To access Original Equipment Manufacturer (OEM) manuals, go to the device manufacturer's Web site.
2
MAC™2000 ECG Analysis System
2053535-004D 31 January 2014
Contents
1
Introduction Ordering Information ... 5 Regulatory and Safety Information... 6 Safety Messages... 7
2
Supplies and Accessories Supplies... 9 Accessories ... 10
3
Maintenance Cleaning, Disinfecting, and Storing ECG Cables and Leadwires... 17 Cleaning Guidelines... 17 Cleaning and Disinfecting Cables and Leadwires... 18 Storing Cables and Leadwires... 19
Cleaning, Disinfecting, and Sterilizing Reusable Electrodes ... 19 Replacing Leadwire Adapters ... 20 Paper Maintenance ... 21 Replacing Paper... 21 Storing Thermal Paper... 22
2053535-004D
MAC™2000 ECG Analysis System
3
4
MAC™2000 ECG Analysis System
2053535-004D
1
Introduction
Quality supplies and accessories for your GE Healthcare device play an important role in ensuring that your system performs at the high level you have come to expect from GE Healthcare. Use this manual as your guide for the GE Healthcare supplies and accessories that have proven compatibility with your device. From electrodes, cables, and leadwires to recording paper, you can be assured that each product listed was tested and validated with the device, enabling your system's performance to be representative of GE Healthcare's quality. You can rely on GE Healthcare as your trusted source for supplies and accessories after your original purchase and throughout the life of your system. Additional information regarding the use of supplies and accessories with this device may be found in the product operator manual or the instructions for use of the particular supply or accessory.
Ordering Information The availability of supplies and accessories varies by country. Contact your local GE Healthcare representative to check on the availability of selected supplies and accessories in your region. Americas
Asia Pacific
North America
Australia
T: 1–800–558–7044, option #2
T: +61 1800 223 615
F: 1–800–421–4841
F: +612 9846 4762
Canada and Latin America for VSD Products
India
T: 1–800–932–0760
T: +91 80 28452923/25/26
F: 1–973–956–5437
F: +91 80 28452924
2053535-004D
MAC™2000 ECG Analysis System
5
Introduction
Canada for GE Legacy Products
Japan
T: 1–800–668–0732, option #3
T: +81 42 585 5111
F: 1–888–988–6822
Korea
T: +82 2 6201 3114 Association of Southeast Asian Nations T: +65 6291 8528
Europe Denmark
Norway
T: +45 43 29 5885
T: +47 23 18 50 50
F: +45 43 29 5701
F: +47 23 18 60 40
[email protected] Finland
Russia
T: +358 10 394 5466
T: +7 495 739 6931
T: +358 10 394 5422
F: +7 495 739 6932
F: +358 9 146 3310 [email protected] France
Spain
T: +33 4 78 66 62 10
T: (0034) 902 100 163
F: +33 4 78 66 79 04 [email protected]
F: (0034) 902 100 178 [email protected]
Germany T: +49 761 4543 601
Sweden
F: +49 761 4543 608
T: +46 8 559 500 10 F: +46 8 559 500 15 [email protected]
Italy T: (0039) 022 6001622
Turkey T: +90 312 289 77 00
F: (0039) 022 6001625
F: +90 312 289 78 02
Netherlands
United Kingdom
T: +31(0) 33 25 41 222 F: +31(0) 33 25 41 223
T: +44 (0) 1707 274183 F: [email protected]
Regulatory and Safety Information This section provides information about the safe use and regulatory compliance of the supplies and accessories for this system. Familiarize yourself with this information, and read and understand all instructions before attempting to use these supplies and accessories.
6
MAC™2000 ECG Analysis System
2053535-004D
Introduction
Safety Messages WARNING: PATIENT SAFETY/EQUIPMENT FAILURE - Using unauthorized supplies or accessories can result in patient injury or equipment failure. To ensure patient safety, use only supplies and accessories manufactured or validated by GE Healthcare and recommended for use with this device. Parts, supplies, and accessories must meet the requirements of the applicable safety standards. The system configuration must meet the requirements of the IEC60601/EN60601-1 Medical Electrical Systems standard. Using accessory equipment that does not comply with the equivalent safety requirements of this equipment may lead to a reduced level of safety of the resulting system. When choosing accessories, consider the following: • Use of the accessory in the patient vicinity. Patient vicinity is defined as a space, within a location intended for the examination and treatment of patients, extending 1.83m (6 ft.) beyond the normal location of the bed, chair, table, treadmill, or other device(s) supporting the patient during examination and treatment, and extending vertically to 2.5m (8 ft., 2.4 in.) above the floor. • Evidence that the safety certification of the accessory was performed in accordance with the appropriate IEC60601/EN60601-1 standard(s). Contact GE Healthcare for information before connecting the device to any accessories that are not recommended in this manual.
2053535-004D
MAC™2000 ECG Analysis System
7
Introduction
8
MAC™2000 ECG Analysis System
2053535-004D
Supplies and Accessories
2
This chapter identifies supplies and accessories that are approved for use with your system. See individual supplies and accessories packaging and labeling for CE marking information.
Supplies Paper Part Number
Description
2009828-061
GE Premium Thermal-Sensitive Chart Paper, Red Grid Blank Interpretation Area, 8.43 in x 11 in. (214.2 mm x 279.4 mm) Sheet, Z-fold, Queue Hole, 150 sheets/pack, 16 packs/case, 2400 sheets/case.
2020314-001
GE Premium Thermal-Sensitive Chart Paper, Full Page Red Grid, A4, 210 mm x 295 mm (8.26 in x 11.61 in.) Sheet, Z-fold, Queue Mark, 150 sheets/pack, 10 packs/case, 1500 sheets/case
22616605
GE Contrast Thermal-Sensitive Chart Paper, Full Page Red Grid, A4, 210 mm x 295 mm (8.26 in x 11.61 in.) Sheet, Z-fold, Queue Mark, 150 sheets/pack, 10 packs/case, 1500 sheets/case
22616606
GE Contrast Thermal-Sensitive Chart Paper, Full Page Red Grid, 216 mm x 280 mm (8.5 in x 11 in.) Sheet, Z-fold, Queue Mark, 150 sheets/pack, 10 packs/case, 1500 sheets/case
22616611
GE Archivist Thermal-Sensitive Chart Paper, Full Page Red Grid, A4, 210 mm x 295 mm (8.26 in x 11.61 in.) Sheet, Z-fold, Queue Mark, 150 sheets/pack, 10 packs/case, 1500 sheets/case
Creams, Gels, Sprays, Pads
2053535-004D
Part Number
Description
2034731-002
Electrode Gel, 250 ml bottle, 4/case
2034741-002
Epicont Cream, 250 ml bottle, 4/case
2046978-001
Electrode Cream, 250 ml bottle, 4/case
21708318
Electrode Cream, 250 ml bottle
21730701
Electrode Contact Spray, 200 ml bottle
MAC™2000 ECG Analysis System
9
Supplies and Accessories
Creams, Gels, Sprays, Pads (cont'd.) Part Number
Description
21730702
Electrode Contact Spray, 200 ml bottle, 10/box
21730705
Electrode Contact Spray, 2 L
401210-001
Signacreme® Electrode Cream, 5 oz bottle, 12/case
401210-003
Signacreme® Electrode Cream, 70 oz bottle w/pump
Accessories Electrodes, Non-polarizing Part Number
Description
2014780-001
SilverTRACE ECG Electrodes, Soft Stress PS50MO, foam round, wet gel, 30/pouch, 300/box
2014783-001
SilverTRACE ECG Electrodes, Window P50TR, clear tape round, solid gel, 30/pouch, 300/box
2014784-001
SilverTRACE ECG Electrodes, Window P50TR, clear tape round, solid gel, 5/strip, 300/box
2014785-001
SilverTRACE ECG Electrodes, Window P50TR, clear tape round, solid gel, 7/strip, 350/box
2014786-001
SilverTRACE ECG Electrodes, First Carbon P28MOC, foam rectangle, wet gel, carbon snap, 30/pouch, 300/box
2046545-001
ECG Electrode, Wet Gel P28 MOC, SilverTRACE Electrodes, 30/pack
21714401
Suction Bulb Electrode, Thorax Electrode
402207-810
BabyMAC Electrodes, Resting ECG Electrodes, 10/card, 50/pack, 500/case
42101600
Suction Bulb 32 x 33 rubber blue
900703-805
SilverTRACE Ag/AgCl Electrodes, Adult Holter/Stress Electrode, Foam Oval, Wet Gel, 5/pkg, 150/box, 600/case
900703-830
SilverTRACE Ag/AgCl Electrodes, Adult Holter/Stress Electrode, Foam Oval, Wet Gel, 30/pouch, 300/case
91920031
SilverTRACE ECG Electrodes, Soft P55MO, foam round, wet gel, 25/pouch, 200/box
9623-810
Silver Mactrode Resting ECG Electrodes, 10/card, 100/pack, 1000/case
9623-810P
Silver Mactrode Plus Resting ECG Electrodes, 10/card, 100/pack, 1000/case
Leadwires
10
Part Number
Description
2001925-003
CAM 14 ECG Leadwire, Universal, 40 in (102 cm)
2001925-004
CAM 14 ECG Leadwire, Universal, 51 in (130 cm) MAC™2000 ECG Analysis System
2053535-004D
Supplies and Accessories
Leadwires (cont'd.)
2053535-004D
Part Number
Description
2001925-005
CAM 14 ECG Leadwire, Universal, 26 in (66 cm)
2001925-006
CAM 14 ECG Leadwire, Universal, 36 in (90 cm)
2016032-001
CAM 14 Leadwire Set, Dedicated Banana, AHA, 10/set, mixed lengths
2016032-002
CAM 14 Leadwire Set, Dedicated Banana, IEC, 10/set, mixed lengths
2020558-001
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 36 in (90 cm), RA
2020558-002
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 36 in (90 cm), LA
2020558-003
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 40 in (102 cm), LL
2020558-004
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 40 in (102 cm), RL
2020558-005
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V1
2020558-006
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V2
2020558-007
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V3
2020558-008
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V4
2020558-009
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V5
2020558-010
CAM 14 ECG Leadwire, Dedicated Banana, AHA, 26 in (66 cm), V6
2020559-001
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 36 in (90 cm), R
2020559-002
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 36 in (90 cm), L
2020559-003
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 40 in (102 cm), F
2020559-004
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 40 in (102 cm), N
2020559-005
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C1
2020559-006
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C2
2020559-007
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C3
2020559-008
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C4
2020559-009
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C5
2020559-010
CAM 14 ECG Leadwire, Dedicated Banana, IEC, 26 in (66 cm), C6
38401765
ECG Leadwire Set with Resistance, Banana, IEC, 10/set, mixed lengths
38401766
ECG Leadwire Set with Resistance, Banana, IEC, NST & NAX, 27 in (70 cm)
38401816
ECG Leadwire Set, Banana, 10/set, IEC, mixed lengths
MAC™2000 ECG Analysis System
11
Supplies and Accessories
Leadwires (cont'd.) Part Number
Description
38401817
ECG Leadwire Set, Banana, 10/set, AHA, mixed lengths
420101-002
CAM 14 ECG Leadwire Set, Universal, mixed length, 10/set
Leadwire Accessories Part Number
Description
401089-003
Leadwire Organizers, 4 3-L Separators, 2 4-L Separators
414763-002
Multi-Link Leadwire Separator, 3-L, 3/pack
Cables Part Number
Description
2029890-001
Value ECG Cable/Leadwires, 10-L, IEC
2029893-001
Value ECG Cable/Leadwires, 10-L, AHA
22336203
Connection cable to CardioSys
22338002
Connection cable for eBike
22339003
Connection cable for T2000/T2100
22340305
ECG Cable, 14-L, IEC, 2.5m (8 ft)
22341808
ECG Cable, Multi-Link, 10-L, IEC, 2.5m (8 ft)
22341809
ECG Cable, Multi-Link, MAC 500/1200, 10-L, AHA, 3m (10 ft)
ECG Adapters and Connectors
12
Part Number
Description
2029891-001
Reusable Limb Clamps, IEC, 4/set
2029892-001
Reusable Bulb Electrodes, 6/set
2029894-001
Reusable Limb Clamps, AHA, 4/set
2056813-010
Electrode Adapter Set, 10/set
900178-001
CAM 14 ECG Connector Set, Banana, 10/set, AHA
900178-002
CAM 14 ECG Connector Set, Mactrode, 10/set, AHA
900178-003
CAM 14 ECG Connector Set, Grabber, 10/set, AHA
900178-101
CAM 14 ECG Connector Set, Banana, 10/set, IEC
MAC™2000 ECG Analysis System
2053535-004D
Supplies and Accessories
ECG Adapters and Connectors (cont'd.) Part Number
Description
900178-102
CAM 14 ECG Connector Set, Mactrode, 10/set, IEC
900178-103
CAM 14 ECG Connector Set, Grabber, 10/set, IEC
KISS Accessories
2053535-004D
Part Number
Description
2024037-001
KISS ES600 Electrodes & Leadwires, Standard, 10/set, mixed lengths
2024039-001
KISS Upgrade Electrodes & Leadwires, NEHB, 2/set, 127 cm (50 in), Nst, Nax
21612113
Electrode Application System KISS 10 Lead without pump
21612202
Electrode Application System KISS 12 Lead without pump
21732801
Suction Electrode, KISS ES600
22341410
Trunk Cable, KISS, 12-L with Tube
22341415
Cable, KISS, 12-L
30344365
Leadwire, KISS, IEC, 127 cm (50 in), C1
30344366
Leadwire, KISS, IEC, 127 cm (50 in), C2
30344367
Leadwire, KISS, IEC, 127 cm (50 in), C3
30344368
Leadwire, KISS, IEC, 127 cm (50 in), C4
30344369
Leadwire, KISS, IEC, 127 cm (50 in), C5
30344370
Leadwire, KISS, IEC, 127 cm (50 in), C6
30344371
Leadwire, KISS, IEC, 147 cm (57 in), F
30344372
Leadwire, KISS, IEC, 147 cm (57 in), L
30344373
Leadwire, KISS, IEC, 147 cm (57 in), R
30344374
Leadwire, KISS, IEC, 147 cm (57 in), N
30344375
Leadwire, KISS, IEC, 127 cm (50 in), NST
30344376
Leadwire, KISS, IEC, 127 cm (50 in), NAX
30344377
Swivel Attachment Arm for Kiss
30344419
Extension tube for KISS ES600 Pump, 1.5m (5 ft)
30344420
Ergometer Mounting Arm, KISS
30344421
Leadwire Clip Adapter, KISS, for disposable electrodes
30344427
Blind Plug for KISS
30344434
Leadwire, KISS, AHA, 127 cm (50 in), V1
30344435
Leadwire, KISS, AHA, 127 cm (50 in), V2
30344436
Leadwire, KISS, AHA, 127 cm (50 in), V3
30344437
Leadwire, KISS, AHA, 127 cm (50 in), V4
30344438
Leadwire, KISS, AHA, 127 cm (50 in), V5 MAC™2000 ECG Analysis System
13
Supplies and Accessories
KISS Accessories (cont'd.) Part Number
Description
30344439
Leadwire, KISS, AHA, 127 cm (50 in), V6
30344440
Leadwire, KISS, AHA, 147 cm (57 in), LL
30344441
Leadwire, KISS, AHA, 147 cm (57 in), LA
30344442
Leadwire, KISS, AHA, 147 cm (57 in), RA
30344443
Leadwire, KISS, AHA, 147 cm (57 in), RL
38401584
KISS Mounting Table Kit
38401590
KISS Leadwire Set, IEC, 10/set, mixed lengths
43252125
Suction Dome, KISS
93204775
KISS Electrode Filter Disc, 100/bag
Barcode Accessories
14
Part Number
Description
2035979-001
Barcode Scanner - English
2035979-002
Barcode Scanner - German
2035979-003
Barcode Scanner - French
2035979-004
Barcode Scanner - Spanish
2035979-005
Barcode Scanner - Swedish
2035979-006
Barcode Scanner - Italian
2035979-008
Barcode Scanner - Dutch
2035979-009
Barcode Scanner - Norwegian
2035979-010
Barcode Scanner - Danish
2035979-011
Barcode Scanner - Czech
2035979-014
Barcode Scanner - Hungarian
2035979-016
Barcode Scanner - Russian
2035979-017
Barcode Scanner - Slovene
MAC™2000 ECG Analysis System
2053535-004D
Supplies and Accessories
Barcode Accessories (cont'd.) Part Number
Description
2035979-018
Barcode Scanner - Portuguese
2035979-020
Barcode Scanner - Finnish
Storage Accessories Part Number
Description
2073012-001
CARD SECURE DIGITAL - 4 GB
Power Cords
2053535-004D
Part Number
Description
401855-001
EURO - PWR SPLY CRD RA CONT EURO 10A 250V 2.5M
401855-002
British - PWR SPLY CRD RA BRITSH 10A 250V 2.5M FSD
401855-003
Italian - PWR SPLY CRD RA ITALIAN 10A 250V 2.5M
401855-004
Israel - PWR SPLY CRD RA ISRAELI 10A 250V 2.5M
401855-110
Australia - PWR SPLY CRD RA AUSTRALIAN 10A 250V 2.5M
401855-018
China - PWR CRD ST CHINA RA PLUG 10A 250V 2.5M
401855-107
Swiss - PWR SPLY CRD ST SWISS 10A 250V 2.5M
401855-108
India - PWR SPLY CRD ST INDIAN 10A 250V 2.5M
405535-006
US - PWR SPLY CRD RA HOSP GRD 13A 125V 10 FT
405535-011
Japan - PWR SPLY CRD ST-RA PSE 10A 250V 10 FT
401855-041
Brazil - PWR SPLY CRD ST BRAZIL 10A 250V 2.5M
MAC™2000 ECG Analysis System
15
Supplies and Accessories
16
MAC™2000 ECG Analysis System
2053535-004D
3
Maintenance
This chapter provides information about the maintenance of the accessories used with your system.
Cleaning, Disinfecting, and Storing ECG Cables and Leadwires In addition to keeping the system clean and in good repair, it is important to keep the cables and leadwires clean and disinfected. This section provides instructions for cleaning, disinfecting, and storing ECG cables and leadwires to extend their life and protect patients. Cables and leadwires come into contact with patients and should be cleaned and disinfected after every use. NOTE: For devices with the KISS system, refer to the KISS operator's manual for cleaning and disinfecting information.
Cleaning Guidelines Observe the following guidelines when cleaning and disinfecting the cables, leadwires, and electrodes for your system. • Follow the cleaning instructions exactly. • Wring excess disinfectant from the wipe before using it. • Never immerse the device, cables, or leadwires in any liquid, as this may corrode metal contacts and affect signal quality. • Do not allow liquids to collect around the connection pins. If this happens, blot them dry with a soft, lint-free cloth. • Never use conductive solutions or solutions that contain chlorides, wax, or wax compounds to clean the device, cables, or leadwires. • Never use solutions or products that contain any type of Ammonium Chloride such as, but not limited to: • Dimethyl Benzyl Ammonium Chloride • Quaternary Ammonium Chloride solutions • Abrasive cleaners or solvents of any kind • Acetone 2053535-004D
MAC™2000 ECG Analysis System
17
Maintenance
• Ketone • Betadine • Alcohol-based cleaning agents • Sodium salts • Never autoclave or steam clean the device, cables, or leadwires. • Do not use any of the accessories until thoroughly dry. • Do NOT immerse either end of a cable or leadwire connector in any solution. Immersing or soaking the connector ends may corrode metal contact ends and affect signal quality. • Do NOT let liquids collect around the connection pins. If this happens, blot them dry with a soft, lint-free cloth.
Cleaning and Disinfecting Cables and Leadwires Proper cleaning and disinfecting prolongs the life of the cables and leadwires. Failure to use the proper cleaning solutions or to follow the proper procedures can result in the following: • Damage or corrosion • Diminished signal quality • Product discoloration • Metal part corrosion • Brittle wires and connectors • Reduced cables and leadwires life • Device malfunction • Voided warranty Cleaning the Cables and Leadwires Use the following procedure to clean the cables and leadwires: NOTE: • While performing the following procedure, use care in cleaning the leadwires to prevent pulling the wires from the connector ends, because the metal connections can be pulled away from the connectors. • Cleaning removes dirt and marks but does not disinfect the cables and leadwires. 1.
Remove the cables and leadwires from the device before cleaning.
2.
Wipe them with a cloth lightly moistened with a mild solution of soap and water. Do not use any of the following cleaning products, or products that contain the same active ingredients and solutions, which are known to cause the problems previously listed: • Sani-Cloth® Wipes • Ascepti® Wipes • HB Quat®
18
MAC™2000 ECG Analysis System
2053535-004D
Maintenance
• Clorox® Wipes (they do not contain bleach) • Over-the-counter detergents (such as Fantastic®, Tilex®, and so on) 3.
Wipe the cables and leadwires with a dry, clean cloth or paper towel and let them air dry.
Disinfecting the Cables and Leadwires Use the following procedure to disinfect the cables and leadwires: 1.
Clean and dry the cables and leadwires before disinfecting them. See “Cleaning the Cables and Leadwires” on page 18 for instructions.
2.
Wipe the cables and leadwires with a soft, lint-free cloth that is moistened with an appropriate disinfectant. Use the following solutions, as recommended in APIC Guidelines for Selection and Use of Disinfectants (1996): • Sodium hypochlorite (5.2% household bleach) minimum 1:500 dilution (minimum 100 ppm free chlorine) and maximum 1:10 dilution. • Any sodium hypochlorite wipe product that meets the previous guidelines.
3.
Dry the cables and leadwires with a clean cloth or paper towel and let them air dry for at least 30 minutes. NOTE: • Drying times vary based on the environmental conditions. • DO NOT use excessive drying techniques, such as ovens, forced heat, or sun drying.
Storing Cables and Leadwires To ensure that the cables and leadwires are in proper working order, use the following guidelines to store them when not in use: • Store cables and leadwires in a dry, well-ventilated area. • Hang cables and leadwires vertically • Do NOT coil cables or leadwires around the device.
Cleaning, Disinfecting, and Sterilizing Reusable Electrodes Clean reusable electrodes immediately after using them on a patient.
2053535-004D
MAC™2000 ECG Analysis System
19
Maintenance
Cleaning and Disinfecting Reusable Electrodes Use the following procedure to clean and disinfect the reusable electrodes: 1.
Use warm water and a small brush to remove any cream or gel from the electrode. Do not use pointed or sharp objects for cleaning.
2.
Disinfect the electrodes with alcohol-free disinfectant. Ensure that the connectors and sockets do not get wet.
Sterilizing Reusable Electrodes Use the following procedure to sterilize reusable electrodes: The only approved sterilization method is gas sterilization. 1.
Sterilize reusable electrodes with ethylene oxide gas (EtO) at a maximum temperature of 50°C (122°F).
2.
After sterilization is complete, follow the manufacturer's recommendations for required aeration.
Replacing Leadwire Adapters Although proper cleaning and storage prolong the life of leadwires, you eventually need to replace the leadwire adapters. The following illustration shows the proper method for replacing adapters.
20
MAC™2000 ECG Analysis System
2053535-004D