OEC 9900 Elite Quick Start Rev A
Quick Start
2 Pages
Preview
Page 1
GE Healthcare
OEC 9900 Elite ®
Quick Start
Start Up
1. Power on.
2. Enter patient information.
3. Select imaging profile.
X-ray Switch Setup (Screens may vary based on model purchased) FLUORO or ROADMAP imaging HLF, DIGITAL SPOT, SUBTRACTION or DIGITAL CINE imaging DIGITAL CINE operation (on selected models) * Select PULSE button to initiate pulsed x-ray. 1. Select Mode
2. Select imaging modes. 3. Change profile if desired.
4. Refer to the status bar on the monitor for active modes.
Save/Retrieve Press
to save image
Print/Archive
1. Press on the keyboard to open image directory.
1. Select COPY TO.
2. Select SAVED EXAMS.
3. Select image or images.
3. Select patient name.
4. Select destination queue.
4. Select OK.
5. Select COPY.
2. Select print or archive device.
Dynamic Recording (Subtraction and Digital Cine are automatically recorded)
1. Select CINE.
2. Select CINE SETUP.
3. Select ACQUIRE ON/OFF.
5. Choose acquisition rate.
4. Select corresponding RATE Button.
Imaging FLUORO 1. Verify FLUORO is displayed on status bar. 2. Press left ( ) X-ray switch. HLF 1. Verify HLF is displayed on status bar. 2. Press right ( ) X-ray switch. DIGITAL SPOT 1. Verify DIG. SPOT is displayed on status bar. 2. Press left ( ) X-ray switch while positioning. 3. Press and hold right ( ) X-ray switch. 4. Release switch after beep.
ROADMAP 1. Change to profile that supports Roadmap 2. Verify Roadmap is displayed on status bar. 3. Press and hold left ( ) X-ray switch. 4. Inject contrast. 5. Release X-ray switch. 6. Press left ( ) X-ray switch. DIGITAL CINE PULSE Vascular-Neuro Vascular Systems 1. Change to profile that supports Cine. 2. Verify HLF is displayed on status bar. 3. Set a pulse rate of 15 or 30 (12 or 25) pps. 4. Press the right ( ) X-ray switch.
SUBTRACT 1. Change to profile that supports Subtract. 2. Verify Subtract is displayed on status bar. 3. Press left ( ) X-ray switch while positioning. 4. Press and hold ( ) X-ray switch. 5. Inject contrast when syringe icon displays. 6. Release X-ray switch when finished. Cardiac Systems 1. Change to Cardiac profile. 2. Display the Mode screen to verify or change Digital Cinepulse rate. 3. Press the far right ( ) X-ray switch.
© 2005 All rights reserved. GE OEC Medical Systems, Inc. 384 Wright Brothers Drive Salt Lake City, Utah 84116 U.S.A. GE OEC Medical Systems, a General Electric company, going to market as GE Healthcare.
imagination at work
00-887361-01 Rev A