GE Healthcare

MAC ECG Analysis Systems

MAC VU360 Quick Reference Guide

Quick Reference Guide

2 Pages

MAC VU360™ Resting ECG Analysis System  Acquisition Screen  2088531-212-1 QUICK REFERENCE GUIDE  Key Icons  Starting a New Patient 1. Select Start New Patient to start a new patient test. 2. Prepare and connect the patient. 3. Enter patient information on the Patient Information screen using any of the following options: • Scanning the patient’s barcode • Performing order or ADT query • Attaching a patient record from the Patients list • Attaching an order from the Orders list • Using the device keyboard to enter the Patient ID or Visit Number on the screen and pressing the Search icon on the respective field 4. Select Save to save the patient information. 5. Verify that the Hookup Advisor status is green and review the waveform. 6. Proceed with recording an ECG, Full Disclosure (FD), or rhythm.  Recording a Rhythm					  Recording an ECG  1. Select Start Rhythm to record a rhythm. If the rhythm mode is: • Paper Only, the rhythm prints. Select Stop Rhythm at any time to stop printing the rhythm strip. • Digital Only, the rhythm digitally records for a configured duration and saved in the Files list, but not printed. Select Stop Rhythm at any time to stop recording. The saved rhythm report displays in the Rhythm tab. • Both, the rhythm digitally records and prints for a configured duration and saved in the Files list. Select Stop Rhythm at any time to stop recording and printing the rhythm strip. The saved rhythm report displays in the Rhythm tab. 2. Review the rhythm report. To continue with the same patient, go back to the Live tab and continue to record the ECG. To start a new patient, select Done or Start New Patient on the screen.  1. Select Start ECG to record an ECG. • If print preview is enabled, the patient report preview displays in the ECG tab. Select Accept to accept the ECG and save the patient report in the Files list, or select Reject to cancel the ECG. • If print preview is disabled, the patient report displays in the ECG tab and is saved in the Files list. The patient report automatically prints in the report format configured on your device. 2. Review the ECG patient report. To continue with the same patient, go back to the Live tab and continue to record the ECG. To start a new patient, select Done or Start New Patient on the screen. To start a new 10 seconds ECG on the same patient from the Full Disclosure (FD) tab, select the FD tab from the patient record menu bar to navigate to the FD waveform and application, and select 10 seconds ECG from the FD waveform.  General user documentation. Copyright General Electric company. GE proprietary. Reproduction and/or distribution is prohibited.  1
File Type: PDF
File Size: 849 KB
File Name: GE Healthcare - 2088531-212-1 - MAC VU360 Quick Reference Guide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions