HAAG-STREIT

HAAG-STREIT Applanation Tonometers

Short Instructions for Disinfection of Measuring Prisms Feb 2014

Short Instructions

1 Page

Short instructions for disinfection of measuring prisms  Excerpt from HAAG-STREIT instruction for use ‘cleaning and disinfection’. Complete instructions for use: www. haag-streit.com  Cleaning  English  60''  ≤60'  600 ml  6. Add at least 600 ml of disinfectant solution. ÎÎ Measuring prisms must be completely immersed in the disinfectant solution. 7. Maximum material-compatible exposure time: 60 minutes.  NOTE! The disinfectant must be replaced as follows: ÎÎ When visibly soiled ÎÎ Once a day or as specified by the manufacturer •• List of Disinfectants: www.haag-streit.com •• HAAG-STREIT recommends Desinset  Rinse off the cleansing agent under running, cold drinking water for 60 seconds. ÎÎ Repeat this cleaning process if visible contamination is still present. 3. Dry with a lint-free disposable cloth. ÎÎ Perform a visual inspection for cleanliness and integrity. ÎÎ  10'–15'  4. Place the cleaned measuring prisms in the Desinset plastic tray. 5. Remove the measuring prisms from the plastic tray and place them on the lower level of the Desinset plastic insert. ÎÎ Measuring prisms must not overlap.  Drying / storing  Disposable gloves recommended (personal security). 1. Remove measuring prism from the holder. 2. Clean for 60 seconds under running water. If necessary, use a pHneutral cleansing agent. ÎÎ  Disinfection / rinsing  FORBIDDEN! Never use damaged measuring prisms. NOTE: If using ‘Tristel Pre-Clean Wipes’, ‘Tristel DUO’ and ‘Tristel Rinse Wipes’, refer to the manufacturers instructions for use.  8. Allow the plastic insert to drip dry and place it in the other measuring beaker. 9. Place the funnel on the plastic insert. ÎÎ Rinse the contents under running water for a minimum of 10 minutes and a maximum of 15 minutes.  10. Remove the plastic insert with the measuring prisms. 11. Dry each measuring prism individually using a soft disposable cloth. 12. Store the measuring prisms in a closed Desinset glass container.  FORBIDDEN! •• Disinfection with alcohol •• Cleaning with acetone •• Disinfection using UV radiation •• Sterilization using steam or ethylene oxide •• Temperatures above 60°C  © HAAG-STREIT AG, 3098 Koeniz, Switzerland - Doc. No. 1500.7220315.04040 – 4. Edition – 2014 – 09  01-IFU_HowToDisinfect-7220315-04040_eng.indd 1  04.09.2014 15:48:37
File Type: PDF
File Size: 486 KB
File Name: HAAG-STREIT - Short Instructions for Disinfection of Measuring Prisms Feb 2014 - 2014-02.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions