HAAG-STREIT

HAAG-STREIT Perimetry OCTOPUS Series

OCTOPUS 301 Perimeter Quick Reference Guide Rev 2

Quick Reference Guide

2 Pages

6.  Installation & Set-Up  Attention: Do not carry the perimeter with the head-rest ! Handle the unit here  7.  Set-up Parameters  For your particular application, you may wish to modify the set-up parameters.  1. Precision by Tradition  Quick Start  ƒ Switch the power ON to get into the main screen.  Here are the most common selections. ƒ On the main screen, touch on the  button.  ƒ Under “Configuration – GENERAL” - select the desired date / time format and the language.  OCTOPUS 301 Perimeter  ƒ Under “Examination – SETUP” specify your default settings such as: enter or skip the patient’s name and ID and which program is routinely used. Patient button socket  ƒ Switch the stimulus beeper ON / OFF. Important: The OCTOPUS 300 Series has an LCD touch screen to operate the perimeter directed by a menu dialog. Although the buttons can be activated with the tip of your finger, you will find it more convenient to use the pointer pen.  ƒ With the pointer pen touch on examination.  to start an  Direct the pointer pen under an angle toward the screen (like in writing) to enable you to see your entries.  The “Examination – PROGRAMS” site allows defining three versions of each program marked P-V1 to P-V3 with different parameters for test strategy, number of catch trials, fixation marks, etc. The perimeter connects to any Voltage from 100– 240 VAC, 50/60 Hz, 40VA. Attention: On the original motorized table, set the voltage selector at the inside panel. ƒ Connect the perimeter power cord to the socket in the table.  For installation instructions and set-up parameters turn to § 6 and 7 in this guide. For more detailed instructions refer to the User’s Manual. Your OCTOPUS distributor will be pleased to help and answer your questions.  ƒ On the “Connections – Setup” site you can edit your reference address that appears on the print-out and the details of a PC connection.  ƒ At minimum, you need to enter the date of birth and select the OD/OS eye.  ƒ Touch on “Connections – Printer” to define the paper size of your printer. All modified settings must be saved with touching on the icon. With every change the icon turns blue to remind you that a modification has been made. 8.  ƒ Connect USB printer cable or PC serial cable to the respective sockets. ƒ Plug the patient button to the socket underneath the head-rest.  The window on the main screen displays information about the software version and installed options.  Upgrading Software  A new Software Version is normally installed with the replacement of the Flash-Module board within the unit. From software version V3.05 such upgrade is also possible by connecting a PC to the OCTOPUS 301 to upload the new version from the HAAG-STREIT web site. To upgrade the OCTOPUS 301 with a new optional feature, such upgrading is usually done by entering a specific key code supplied by the factory.  HAAG-STREIT AG Gartenstadtstrasse 10, 3098 Köniz/Bern, Switzerland Tel: +41 31 978 0111 Fax: +41 31 978 0282 E-mail: info@haag-streit.ch  01-02 HAAG-STREIT No. 4-0200-1000 (Revision 2)  ƒ Touch on the input fields corresponding to Name and or Date of Birth and type in the patient data. You may use capital, small characters and numbers as they appear on the three keyboard levels. ƒ Continue by touching Esc . ƒ The OK button will turn blue OK to inform you that you can start the examination. (Close the ocular cap during calibration before the first examination).
File Type: PDF
File Size: 285 KB
File Name: HAAG-STREIT - OCTOPUS 301 Perimeter Quick Reference Guide Rev 2.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions