Hill-Rom
Compella Bariatric Bed System P7800A Quick Tips Rev 1 Nov 2014
Quick Tips
25 Pages
Preview
Page 1
Compella™ Bariatric Bed Advancing Bariatric Care
Quick Tips
© 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Compella™ at a glance
Patient Controls Intellidrive® Power Transport
Sturdy, increased Siderail Coverage
FlexAFoot™ Length Adjustment
Surface Options: Foam, Air and Pulmonary
One-Button Chair 3 Mode Bed Exit Head of Bed Alarm
Integrated Scale Central Brake & Alarm
Battery Backup Page 1 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Powered frame & surface width adjustment (101 – 127cm)
Caregiver Controls Cardiac Chair
Width Adjustment Page 2 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Bed not Down Flashing Indicator
Bed Flat
Lock Controls
Caregiver Control Pod Weigh Function OIML Zero the Scale
Digital display
HOB Alarm
Zero Instructions
Scale reference position Steer pedal indicator
Page 3 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Bed exit silence Raise the bed
Enable Key
3 Mode PPM Alarm
Zeroing Scale - Set up for new patient Scale should be zeroed prior to placing a patient on the bed. Be sure to put ALL linens, pillows, and equipment on the bed prior to zeroing the scale.
How to Zero the Scale: • Press the “Enable Key” • Make sure that the bed is in the “Scale Reference” position. When you release the brake for this position the “Brake Not Set” alarm will sound • Press and hold the “O/T” control. ‘Hold’ will show on the display • Continue to hold the “O/T” control until ‘CALC’ flashes on the display, then release the control. Do not touch the bed until the display stops flashing ‘CALC’ and shows 0.0 on the display. • The zero procedure is complete when 0.0 is displayed, the “O/T” control is green and a single beep is heard • The brakes can now be engaged Page 4 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Weighing Patient Verify patient is lying in the center of bed. Remove all equipment, drainage bags, excess linens that have been added on the bed since the scale was zeroed Ensure the bed is not in Transport Mode and is in the Scale Reference position (head of bed flat, bed in lowest position and brake and steer pedal in neutral position
How To Weigh A Patient: •
Patient weight range 113kg - 454 kg
To weigh patient, simply press and release the “Scale” control
• Once released, the current patient weight will be displayed in increments of 1 whole kg • Once completed the brake may be set and head section raised • If weight is needed to be seen to the nearest 0.5kg, press the “Mag Mode” control, the previous weight will be shown to the nearest 0.5kg for 5 seconds Page 5 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Caregiver Control Pod – Non OIML version a
d
Page 6 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
c
b
e
f
g
a
Weigh
b
Zero Scale
c
Head of Bed Alert
d
Raise Bed Indicator
e
Enable Control
f
Bed Exit Silence
g
Bed Exit Modes
Zeroing Scale - Non OIML version Scale should be zeroed prior to placing a patient on the bed. Be sure to put ALL linens, pillows, and equipment on the bed prior to zeroing the scale.
How to Zero the Scale: • Press the “Enable Control” • Press and hold the “Zero Control” until 00.0 is shown. • Release the control pod • Scale display will show ‘CALC’. Do not touch the bed until the display stops flashing ‘CALC’ and shows 0.0.
Note: Bed exit cannot be armed if bed is in transport mode. If you attempt to arm, a triple beep alert will sound and the raise bed indicator light will flash. Remove bed from transport mode by pressing and holding the raise bed indicator until single audible confirmation beep sounds. Bed exit is ready to be armed
Page 7 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Weighing Patient - Non OIML version Verify patient is lying in the center of bed. Remove all equipment, excess linens not included on the bed when the scale was zeroed
How To Weigh A Patient: •
To weigh patient, simply press the “Weigh” control
• Once released, the current patient weight will be displayed • The default setting for the scale is kg
Note: Bed exit cannot be armed if bed is in transport mode. If you attempt to arm, a triple beep alert will sound and the raise bed indicator light will flash. Remove bed from transport mode by pressing and holding the raise bed indicator until single audible confirmation beep sounds. Bed exit is ready to be armed
Page 8 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Lockout Controls Lockout controls allow caregiver to disable the bed articulating functions to prevent patient positioning features from being used.
To Activate: • Simultaneously press “Lock” button and specific lockout control desired •
A single audible confirmation beep will sound and amber indicator light will illuminate on the lock for feature
•
Both patient and caregiver controls are locked out
To Deactivate: • Simultaneously press “Lock” button and specific locked control desired • A single audible confirmation beep sounds and amber light disappears when a lockout is deactivated Longer Shorter Page 9 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
CPR The CPR controls are located on the patient right hand side of the footboard.
1.
Deflate air surface • Turn CPR mechanism a quarter turn clockwise. Mattress will begin to deflate. When mattress is completely deflated the bed’s sleep deck can be used as a backboard.
2.
Lower head of bed • To quickly level bed, pull and hold red CPR handle until head section is lowered to a flat position
Note, if using a foam mattress, only activation of CPR on bed frame is required (Step 2).
Page 10 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Powered Width Expansions The bed width can be adjusted to either 101-127cm with the push of a button. The automated adjustment controls both the bed frame and surface.
To adjust, press and hold the “Width Expand” or “Width Retract” until bed adjustment is complete •
A single audible confirmation beep will sound and green indicator light will illuminate to confirm the bed has reached transport mode
•
If bed adjustment is NOT completed, a triple beep alert will sound and an amber indicator light will flash. Continue to press and hold expand or retract until width adjustment is completed
Page 11 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
FlexAFoot® Bed Length Adjustment The bed length can be adjusted to either 80”or 88” with the push of a button. The automated adjustment controls both the bed frame and surface.
To lengthen the foot section-press and hold the “Foot Longer” control until the foot section is at the desired length
To shorten the foot section-press and hold the “Foot Shorter” control until the foot section is at the desired length
Page 12 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Bed Exit Patient Position: patient moves toward either siderail or moves away from the head section, such as sitting up in bed. Exiting: patient moves away from the center of the bed towards an egress point. Out of Bed: patient’s weight shifts significantly off the frame of the bed.
To Activate: • • •
Ensure patient is on the bed. Press “Enable” control. Press desired mode control. When system beeps and indicator light illuminates, the system is armed
To Deactivate: • •
Press the “Enable” Control. Press desired mode control. When system beeps one time and the indicator light goes off, system is deactivated
Note: Bed exit cannot be armed if bed is in transport mode. If you attempt to arm, a triple beep alert will sound and the raise bed indicator light will flash. Remove bed from transport mode by pressing and holding the raise bed indicator until single audible confirmation beep sounds. Bed exit is ready to be armed
Page 13 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Bed Exit Silence Bed Exit can be silenced without deactivating system – system stops monitoring patient movement and will not alert so you can help reposition the patient or assist the patient out of the bed.
To silence before bed exit alerts: • Press “Enable” control • Press “Alert Silence” control until indicator light illuminates
To silence during an alert: • Silence alert by pressing “Alert Silence” control until indicator light illuminates
The system will attempt to re-arm every 30 seconds. Once patient is positioned in center of bed and patient weight is detected:
System will automatically arm to the previously set bed exit mode -- OR -System can manually be re-arm by pressing “alert silence” control.
The system will exit silence mode and re-arm to monitor patient movement
Page 14 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Head-of-Bed (HOB) Angle Alert The digital display on control pod continuously shows angle of head section. To help maintain a head elevation of greater than 30-degrees, an alert can be set to sound if head of bed drops below 30-degrees
To Activate: • Raise the HOB above 30-degrees • Press “Enable” control • Press the “HOB alert” control. A single beep confirmation will sound and the HOB indicator light will illuminate.
To Deactivate: • Press the “Enable” control • Press the 30° head-of-bed button
Page 15 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Engaging Transport Mode Powered transport option enables caregiver to move bed with minimal effort during transport.
1.
Press green Transport control to lower the bed into transport position •
2.
A single audible confirmation beep will sound and green indicator light will illuminate to confirm the bed has reached transport mode
Set the green brake pedal to Steer •
A green indicator light will illuminate once brake pedal has been set to steer
Page 16 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Preparing Bed for Transport 1.
Raise siderails into locked position
2.
Press and hold “Width Retracted” control until bed is fully retracted
3.
Press and hold “FlexAFoot” control to adjust length of bed, if necessary
4.
Unplug power cords and store on blue cord wraps
5.
On Transport Pod, press green Transport control to lower the bed into transport position
6.
Set the green brake pedal to “Steer”
7.
To move bed, grip blue transport handles and depress green enable switches • •
Push to move forward Pull to move backwards
Page 17 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
After Transport 1.
Disengage transport mode by pressing “Disengage” control to raise bed out of transport position
1.
Position bed and then, set the orange brake pedal to “Brake”
2.
Plug power cords into AC power
3.
Press and hold “Width Expand” control until bed is fully expanded
4.
Press and hold “FlexAFoot” control to adjust length of bed, if necessary
Page 18 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Surface Controls - Air Supply Unit Arrows
Menu
• • • •
Enter
Menu – selects the menu options Enter – moves to and from Patient Setup screen Help – shows Help screen Arrows – selects settings on Patient Setup screen
Page 19 © 2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 189563 rev 1 10-NOV-2014 ENG - US
Help