Page 1
Hillrom Centrella
MEDICAL-SURGICAL HOSPITAL BED
Includes optional patient safety applications available in select countries: •
Heart and Respiration Rate Monitoring System
•
Voalte Nurse Call System
•
WatchCare Incontinence Management System
Instructions for Use
Product No. P7900 193587 REV 15
QUICK VIEW LIST OF BED FEATURES
Item
Feature
A
Page
Item
Feature
Page
Transport/push handle (optional) 129
M
Drainage bag holder
18
B
Line Managers
24
N
SafeView+ Alerts indicator with floor projections (optional)
26
C
Graphical Caregiver Interface (GCI) Control
44
O
Corner bumpers and equipment sockets
22
D
Caregiver control panel
33
P
Footboard cord storage
21
E
Headboard cord storage
21
Q
Patient storage area
26
F
Brake and steer control
19
R
Patient pendant (handheld remote) (optional)
39
G
CPR handle
17
S
Patient control panel
38
H
Patient Hip Position indicator
22
T
Speaker with optional USB charging port
25
I
Patient Restraint point
18
U
Patient pendant (handheld remote) holder
39
J
IntelliDrive Transport System (power transport-optional)
119
V
IllumiGuide Siderail Handgrip (siderail light-optional)
24
K
Auxiliary outlet (optional)
32
W
Urinal holder
25
L
FlexAfoot Retractable Foot Mechanism
49
X
Bed Feature label
8
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
i
PATENTS / PATENT hillrom.com/patents May be covered by one or more patents. See the above Internet address. The Hill-Rom companies are the proprietors of European, US, and other patents and pending patent applications. FOSS This product may contain software known as “free” or “open source” software (FOSS). Hill-Rom uses and supports the use of FOSS. We believe that FOSS makes our products more robust and secure, and gives us and our customers greater flexibility. To learn more about FOSS that may be used in this product, please visit our FOSS website at hillrom.com/opensource. Where required, a copy of FOSS source code is available on our FOSS website. Legal Manufacturer: HILL-ROM, INC. 1069 STATE ROUTE 46 E BATESVILLE, IN 47006-9167 USA Authorized European Union Representative and EU Importer: HILL-ROM SAS B.P. 14 - Z.I. DU TALHOUET 56330 PLUVIGNER FRANCE TEL: +33 (0)2 97 50 92 12
Authorized Australian Sponsor: HILL-ROM PTY LTD 1 BAXTER DRIVE OLD TOONGABBY NSW 2146 TEL: 1800 650 083
No part of this text shall be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information or retrieval system without written permission from Hill-Rom Services, Inc. (Hill-Rom). The information in this manual is confidential and may not be disclosed to third parties without the prior written consent of Hill-Rom. The information in this manual is subject to change without notice. Hill-Rom makes no commitment to update or keep current the information in this manual. Hill-Rom reserves the right to make changes without notice in design, specifications, and models. The only warranty Hill-Rom makes is the express written warranty extended on the sale or rental of its products. Notice to Users and/or Patients in EU-Any serious incident that has occurred in relation to this device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established. This manual (193587) was originally released and supplied in English. For a list of available translations, contact Hill-Rom Technical Support. Product images and labels are for illustrative purposes only. Actual product and label may vary. Fifteenth Edition, 2023-02 First Printing, 2017 Bluetooth is a trademark of Bluetooth Sig, Inc. CSA is a trademark of Canadian Standards Association, Inc. ii
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Clorox Healthcare is a trademark of The Clorox Professional Products Company, Inc. Oxivir TB and Virex are trademarks of DIVERSEY, Inc. Oxycide is a trademark of EcoLab USA, Inc. Wex-Cide is a trademark of Wexford Labs, Inc. The UL logo is a trademark of Underwriter’s Laboratories, Inc. Baxter, Auto Contour, Boost, Centrella, Dining Chair, Experience Pod, FlexAfoot, Graphical Caregiver Interface (GCI), Hillrom, IllumiGuide, IntelliDrive, Line-of-Site, Microclimate Management MCM, Obstacle Detect, Point-Of-Care, Quick View, ReadyConnect, SafeView, SideCom, SmartSync, Voalte, WallGuard and WatchCare are trademarks of Baxter International Inc. or its subsidiaries. Replace this manual (193587) if it is damaged and/or cannot be read. For product support or to order additional copies of this manual (193587), contact your distributor, local Hill-Rom representative, or go to hillrom.com. Reference Documents Centrella Smart+ Bed Service Manual (193588) Centrella Smart+ Bed Unpacking Instructions (193589) WatchCare User and Service Manual (196414) pro+ Mattress Instructions for Use (209196) pro+ Mattress Service Manual (209197) Hillrom ReadyConnect System Instructions for Use and Service Manual (217064) Hillrom ReadyConnect System Wall Module Installation (216777)
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
iii
NOTES:
iv
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Table of Contents Quick View List of Bed Features... i Intended Use... 1 Introduction... 1 Safety Information... 1 Symbols... 4 Product Symbols... 4 Caregiver Control Panel... 5 Graphical Caregiver Interface (GCI) Control (Touchscreen)... 6 Other Touchscreen Symbols... 7 Foot End Feature Label... 8 Patient Pendant (Handheld Remote) Option... 9 Siderails... 9 Bed Frame... 9 Foot-End SafeView+ Alerts Option... 11 Experience Pod (overhead arm) Device Option... 12 Other... 12 Alarm, Alerts, and Information Indicators... 13 Low Priority Alarm... 13 Beep Alerts... 13 Verbal Alerts... 14 Bed Exit Indicator... 14 Alert Silence Indicator... 14 Brake Not Set Alert... 14 Service Required Indicator... 14 Bed in Lowest Position Indicator... 14 Battery Charging Indicators and Battery Backup... 15 Bed Frame Battery Backup... 15 Powered Transport Battery Charge Indicator... 16 Bed Frame Features... 17 CPR Control... 17 Use the CPR Control... 17 Patient Restraints and Drainage Bag Holders... 18
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
v
Table of Contents
Patient Restraints... 18 Drainage Bag Holders... 18 Power Cord... 19 Cord Holders... 19 Brake and Steer Controls... 19 Headboard... 21 Footboard... 21 Equipment Sockets... 22 WallGuard Bumper System... 22 Hip Position Locator... 22 Line-of-Site Angle Indicators... 22 Head and Intermediate Siderails... 23 IllumiGuide Siderail Handgrip Option... 24 Light Status... 24 Line Manager... 24 USB Charging Port... 25 Urinal Holder... 25 Patient Storage... 26 Motion Activated Night Light... 26 SafeView+ Alerts Option... 26 SafeView+ Alerts Indicators Status... 26 Experience Pod Device (Overhead Arm) (P7926A and P7926A07) Option... 28 Auxiliary Outlet Option... 32 Point-Of-Care Bed Controls... 32 Caregiver Bed Controls... 33 Bed Exit Alert System... 33 Lockout... 34 Bed Up/Down... 35 Obstacle Detect System... 35 Head Up/Down... 36 Knee Up/Down... 36 Foot Up/Down... 36 Trendelenburg and Reverse Trendelenburg... 37 Boost Position System... 37 Patient Controls... 38 vi
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Table of Contents
Nurse Call Control... 38 Head Up/Down... 39 Knee Up/Down... 39 Auto Contour Feature... 39 Patient Pendant (Handheld Remote)... 39 SideCom Communication System... 41 Nurse Call Control... 41 Wireless Connectivity Option... 42 Wireless and Bed Location Indicators on the Touchscreen... 42 Wireless Status... 42 Bed Location... 43 Asset Tag... 43 Hillrom ReadyConnect System... 43 Voalte Nurse Call System... 43 WatchCare Incontinence Management System... 44 SmartCare Remote Management... 44 Graphical Caregiver Interface (GCI) Controls... 44 Use the Touchscreen Menu Controls... 46 Help (?) Menu... 47 Head Angle <30° Limit... 47 Dining Chair Position... 48 Stand Assist... 48 Bed Flat... 49 FlexAfoot Bed Length Adjustment... 49 Bed Exit Alert System... 49 Bed Exit Mode Descriptions... 49 To Silence the Bed Exit Alert without Deactivating the System... 51 Scale... 52 Scale “A”... 52 To Zero the Scale... 53 Required Bed Position to Zero the Scale... 53 New Patient (Zero)... 54 Re-Zero (Same Patient)... 55 To Weigh the Patient... 56 Required Bed Position to Weigh the Patient... 56 Centrella Smart+ Bed Instructions for Use (193587 REV 15)
vii
Table of Contents
Scale “A” Specifications... 58 Scale “B”-NAWI Compliant (EN 45501)... 58 To Zero/Tare the Scale... 59 Required Bed Position to Zero the Scale... 59 Zero (New Patient)... 60 Re-Zero (Same Patient)... 62 +/- (Change Zero Items)... 63 To Weigh the Patient... 64 Optimum Bed Position to Weigh the Patient... 64 Scale “B” Specifications... 66 To Troubleshoot Scale Messages... 66 Settings/Preferences... 68 Software Update... 68 SafeView+ Alerts Floor Projections Option-ON/OFF... 68 IllumiGuide Siderail Handgrip (blue light only)-ON/OFF... 69 Siderail Protocol... 70 USB Charging Port-On/Off... 70 Voice Alerts... 71 Mattress Features... 72 Screen Brightness... 73 Foley Position Limit... 74 Bedside Association... 74 Set Up the Bed Association through the Settings Menu... 75 Set Up the Bed Association Using the Room/Patient Icon... 77 Associate a Room to the Bed... 77 Verify the Patient Identity... 78 Confirm the Room to Bed Association... 78 Override the Room to Bed Association... 78 Verify the Patient Identity when Zeroing the Scale... 79 New Patient Assignment and Bedside Association... 80 Weighing and Bedside Association... 80 HR/RR Monitoring and Bedside Association... 81 Bedside Association Notes:... 82 Heart and Respiration Rate Monitoring System... 83 Intended Use... 83 viii
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Table of Contents
Symbols... 83 Document Symbols... 83 Product Symbols... 84 GCI Symbols-HR/RR Monitoring System... 85 HR/RR Monitoring System Specification... 85 HR and RR Monitoring System Information... 85 Introduction... 88 Alarm, Alerts, and Information Indicators... 89 Low Priority Alarm... 89 Low Priority Alarm Parameters (HR/RR Monitoring System)... 89 Beep Alerts... 89 Activate the Trial Mode... 90 Activate the Licensed Mode... 92 Reset HR and RR Data... 93 Turn ON/OFF HR and RR Display... 95 HR and RR Trends Screen... 96 To View HR and RR Trends... 97 Change HR and RR Alarm Thresholds... 97 Alarms... 98 Turn On/Off In-Room Alarms... 100 Turn On/Off Remote Alarms... 101 Change HR and RR Alarm Volume... 101 View HR/RR Alarm Log... 102 Turn ON/OFF HR and RR Monitoring... 102 View Sensor Expiration Information... 103 HR/RR Monitor Activated Label Option... 104 Voalte Nurse Call System-HR/RR Monitoring... 104 Hillrom Digital Health Gateway-HR/RR Monitoring... 104 Mattress Information... 104 Modes... 105 Normal... 105 Max Inflate... 106 Patient Comfort... 107 To Adjust the Firmness... 107
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
ix
Table of Contents
To Turn On/Off the Patient Comfort Controls on the Patient Pendant (Handheld Remote)... 107 pro+ Mattress... 108 Turn Assist... 109 Continuous Lateral Rotation (CLR)... 110 Setup... 112 Rotation Preview... 112 Start Rotation... 113 Rotation History... 114 Stop Rotation... 114 Mattress Removal... 115 Transport The Patient... 116 Transport Safety Information... 116 Prepare the Bed for Transport... 118 To Transport... 118 Use the Powered Transport System... 119 Power Loss during Transport... 120 After Transport... 120 Accessories... 121 Line Managers (P7512)... 121 IV Poles (P2217 and P7511)... 121 Removable IV Pole (P2217)... 122 Permanent IV Pole (P7511)... 122 Infusion Support System (P158)... 122 Transport Shelf (7524)... 123 Oxygen Tank Holder, E-Size (P276A) HX or F-Size (P009408)Patient Helper (P7934 or P7936)... 124 Patient Helper Bracket Support (P7928) and Patient Helper Sleeve (P3212)... 127 Patient Helper Bracket Support (P7938) and Patient Helper Sleeve (P3212)... 128 Patient Helper Bracket Support (P7938) and HD Patient Helper Mount (P7939)... 128 Traction Frame (P7927 or P7937)... 128 Push Handles Option... 129 Cleaning and Disinfecting... 129 Recommendations... 130 Cleaning and Disinfection... 130 x
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Table of Contents
Prepare the Bed for Cleaning and Disinfecting... 131 STEP 1: Cleaning... 131 STEP 2: Disinfection... 134 Prepare the Bed for Use... 134 Laundry Guidelines... 134 Preventive Maintenance... 135 Batteries... 136 Bed Frame... 136 IntelliDrive Transport System... 136 Decommissioning and Disposal Instructions... 137 Service Calls... 137 Troubleshooting... 138 Power Loss... 138 The Bed Does Not Lower... 138 Specifications... 139 General Wireless Recommendations... 146 Wireless Connectivity Specifications... 147 Standards... 147 Encryption... 147 Extensible Authentication Protocol Types (EAP Types)... 147 Wireless System Characteristics... 148 WiFi and Bluetooth Radio Approval... 148 Regulatory Information... 148 USA-Federal Communications Commission (FCC) Radiation Exposure Statement... 149 Interference Statement for FCC... 149 Canada-Industry Canada (IC)... 149 Department Identification Label Placement... 151
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
xi
Table of Contents
NOTES:
xii
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
INTENDED USE The Centrella Smart+ Bed is intended for use in healthcare environments as a patient support system to prevent and/or treat pressure injuries. It is intended for a broad patient population as determined appropriate by the caregiver or institution. It is intended for patient populations weighing at least 70 lb (32 kg) and is capable of supporting patients up to 500 lb (227 kg). The Centrella Smart+ Bed is intended to assist clinical staff by relaying bed data to hospital communication systems for display and monitoring. For the Intended Use of the Heart and Respiration Rate Monitoring System (HR and RR Monitoring System), see “Intended Use” on page 83.
INTRODUCTION The Centrella Smart+ Bed is a patient support platform that helps improve patient safety and satisfaction. This manual contains information necessary for the normal operation of the Centrella Smart+ Bed and Centrella Mattresses from Hill-Rom. Before you operate the bed, make sure that you read and understand in detail the contents of this manual. It is important that you read and strictly obey the aspects of safety contained in this manual. Any reference to a side of the bed is from the patient’s view lying in the bed on his or her back. The bed is equipped with a scale intended to weigh the patient in the bed. To identify which revision of bed you have, look at the serial number label. The label is on the right side of the upper frame at the head end of the bed. The letter that follows P7900 identifies the bed revision.
NOTES: •
Throughout this manual the wall outlet for electric AC power (mains power), we identify as AC power.
•
Beds with the HR and RR Monitoring System are equipped with a sensor under the mattress on the head section. Contact your local Hill-Rom representative for more information.
SAFETY INFORMATION CONTRAINDICATION: Contraindication-Use of active therapy surfaces (mattresses) with patients with unstabilized spinal cord injury could cause serious injury to the patient. WARNING: Obey all warnings throughout the manual. Failure to do so could cause injury and/or equipment damage: •
Warning-Read and understand all warnings in this manual and on the unit itself prior to use with a patient.
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
1
Safety Information
WARNING: (Warnings continued) Obey all warnings throughout the manual. Failure to do so could cause injury and/or equipment damage:
2
•
Warning-Follow the product manufacturer’s instructions.
•
Warning-The Centrella Smart+ Bed with or without the Heart and Respiration Rate Monitoring System, has an intended patient range of 70 lb (32 kg) to 500 lb (227 kg). Use of the bed with patients outside the intended patient weight range may increase the risk of entrapment, asphyxiation, and/or loss of therapeutic value. Use of the bed with patients above the bed’s intended maximum patient weight may also cause damage to the bed.
•
Warning-Evaluate patients for entrapment and fall risk according to facility protocol, and/or healthcare provider directives, and monitor patients appropriately. Make sure all siderails are fully latched when in the raised position. Failure to do either of these could cause serious injury or death.
•
Warning-The potential for electrical shock exists with electrical equipment. Failure to follow facility protocols may cause death or serious injury.
•
Warning-To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.
•
Warning-Make sure to use a correctly grounded, three-prong, 120 V outlet (NEMA 5-15R or NEMA 5-200R outlet, rated 125 V AC, 15 A or 125 V AC, 20 A, respectively). Failure to do so could cause personal injury, fire, or damage to the equipment or facility wiring.
•
Warning-To help prevent the risk of hospital bed fires, make sure facility persons follow the safety tips in the FDA Public Health Notification: Safety Tips for Preventing Hospital Bed Fires. (US only)
•
Warning-Connect the power cord to hospital grade receptacles only.
•
Warning-Incorrect use or handling of the power cord may cause damage to the power cord. If damage has occurred to the power cord or any of its components, immediately remove the bed from service, and contact Hill-Rom.
•
Warning-Do not use a power cord with a transparent plug. This will cause the inability to establish a connection over Bluetooth and also the wireless nurse call.
•
Warning-The Centrella Smart+ bed has been tested to multiple safety standards (IEC 60601-1, IEC 60601-2-52 etc.). The use of non Hillrom approved components (including power cords) may impact the validity of safety standard reports for the bed.
•
Warning-Take care to minimize the risk of tripping over the power cord by carefully locating it from the unit to its power source.
•
Warning-Make sure the position of the unit is such that you can quickly, without obstruction, unplug the power cord from the main power supply if necessary.
•
Warning-Do not use the bed in an oxygen rich environment or with oxygen tents.
•
Warning-Do not operate the bed in the presence of flammable gas or vapors.
•
Warning-Do not operate the bed in the presence of flammable anesthetics or nitrous oxide.
•
Warning-Before maintenance or service is done on the unit, make sure to unplug the unit and remove the patient or fully remove the unit from use.
•
Warning-Make sure that there are no foreign objects in the patient zone of the unit.
•
Warning-If the cushions appear too firm or too soft after you use the Patient Comfort Adjustment controls, contact Hill-Rom.
•
Warning-Air pressure in the Centrella max mattress is controlled automatically and may adjust without notice. Use care when you perform medical procedures on the patient. Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Safety Information
WARNING: (Warnings continued) Obey all warnings throughout the manual. Failure to do so could cause injury and/or equipment damage: •
Warning-Only use an approved Hillrom mattress on the Centrella Smart+ Bed or a risk of patient entrapment could occur.
•
Warning-Use only Hillrom specified mattresses, parts, and accessories. Do not modify the bed system without authorization from Hill-Rom.
•
Warning-Do not transfer the patient from one bed frame to another using the mattress with a patient on it.
•
Warning-Use a minimum of two caregivers to transfer a patient on to the mattress.
•
Warning-When you put a patient on to the mattress, make sure that the opposite siderails are raised or that another caregiver is present on the opposite side.
•
Warning-Operate the bed within the stated environmental conditions; see “Environmental Conditions for Use” on page 140.
•
Warning-The device is not compatible for use in Magnetic Resonance Imaging (MRI). Transfer the patient to a compatible surface to do an MRI and remove the bed from the MRI room.
•
Warning-If the battery backup does not operate correctly (the bed does not articulate when you press an articulation control), plug the bed into AC power so that you can use the bed controls if necessary.
•
Warning-Do not connect the power cord to an extension cord or multiple outlet strip. There is a risk of overheating and fire may cause injury or damage.
•
Warning-Connect only items that have been specified as parts of the device or compatible with the device.
•
Warning-Report to bed authorized maintenance persons any unusual sounds, burning odors, or movement deviations observed in the controls, motors, or limit switch functions.
•
Warning-Consult your local regulations to safely discard or recycle electronic equipment and batteries.
•
Warning-Do not discard as unsorted municipal waste. See your local distributor for collection and/or recycling system available in your country.
•
Warning-This product can expose you to chemicals including Lead and Di(2-ethylhexyl) phthalate (DEHP), which are known to the State of California to cause cancer, and Lead and Di(2-ethylhexyl) phthalate (DEHP), which are known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
•
Warning-The bed should be left in the lowest position when the patient is unattended.
•
Warning-Federal USA law restricts this device to sale by or on the order of a physician.
•
Warning-Make sure patient hands are kept away from moving parts while operating the bed.
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
3
Symbols
CAUTION: Obey all cautions throughout the manual and also the safety information below. Failure to do so could cause equipment damage: •
Caution-Do not store anything under the bed.
•
Caution-Use only parts and accessories from Hill-Rom. Do not modify or change the bed system without approval from Hill-Rom.
NOTE: The safety information for the HR and RR Monitoring System is on page 85.
SYMBOLS This instructions for use contains different typefaces and symbols to make the content easier to read and understand: •
Standard text-used for regular data.
•
Boldface text-emphasizes a word, phrase, or trademarks.
•
NOTE:-sets apart special data or important instruction clarification.
•
CONTRAINDICATION, WARNING, or CAUTION
–
A CONTRAINDICATION identifies situations or actions that may have an effect on patient safety.
–
A WARNING identifies situations or actions that may have an effect on patient or user safety. To ignore a warning could cause patient or user injury.
–
A CAUTION identifies special procedures or precautions that persons must obey to help prevent equipment damage.
PRODUCT SYMBOLS These symbols may or may not be on your configuration of the bed. For more information about a feature, go to the page number shown for the feature in the tables below.
NOTE: For product symbols for the pro+ mattress, see the pro+ Mattress Instructions for Use (209196).
4
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Symbols
Caregiver Control Panel
Item
Description
Page
Item
Description
Page
A
Alert silence control with LED indicator
14
H
Set brake indicator
14
B
Bed Exit Alert ON indicator
14
I
Battery charging indicator
15
C
Head up and down controls with lockout indicator
36
J
Nurse call control with LED indi- 41 cators
D
Knee up and down controls with lockout indicator
36
K
Reverse Trendelenburg control with lockout indicator
37
E
Foot up and down controls with lockout indicator
36
L
Trendelenburg control with lockout indicator
37
F
Bed up and down controls with lockout indicator
35
M
Boost Position control
37
G
Bed in the lowest position indicator
14
N
Lockout control-locks out bed 34 articulation controls
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
5
Symbols
Graphical Caregiver Interface (GCI) Control (Touchscreen)
Item
Description
Page
Item
Description
Page
A
Help (?) control
46
L
HR/RR Menu control
85
B
Service required indicator
14
M
Settings/Preferences Menu control
68
C
Bed battery charge indicator
15
N
MCM control (only on beds with a pro+ mattress)
108
D
Voalte Nurse Call System Connection (optional)
104
O
Chair control
48
E
Location control (optional)
43
P
Bed Flat and level control
49
F
WiFi indicator
42
Q
FlexAfoot bed length adjustment control
49
G
Home Menu control
45
R
Stand Assist control
48
H
Alerts Menu control
13
S
<30° Limit control
47
I
Mattress Menu control (only 104 on beds with a Centrella max mattress)
T
Ready for New Patient indicator
55
J
Scale Menu control
52
U
Bed Exit Alert Status indicator 49
K
Down (and up) arrow control
46
V
Head Angle display
6
22
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
Symbols
Other Touchscreen Symbols Symbol Description Position Mode Bed Exit Alert-ON indicator
Page
Symbol Description
Page
49
Turn Assist-patient right indicator
109
Exiting Mode Bed Exit Alert- 49 ON indicator
Turn Assist-patient left indicator
109
Out of Bed Mode Bed Exit Alert-ON indicator
49
Max Inflate status indicator (only on Centrella max mattress)
106
Bed Exit Alert system-OFF indicator
50
Adjust Bed Button control (for 53 zero scale)
Position Mode Bed Exit Alert-SILENCED indicator
51
Adjust Bed Button control (for 55 weigh patient and turn assist)
Exiting Mode Bed Exit Alert- 51 SILENCED indicator
Hold to Adjust control (for weigh patient with a NAWI compliant scale)
59
Out of Bed Mode Bed Exit Alert-SILENCED indicator
51
Not In Optimum Position when patient was weighed
55
Voalte Nurse Call System Patient Safety Monitoring- SUSPENDED indicator
41
Foley Limit status-ON
74
Voalte Nurse Call System Patient Safety Monitoring- ON indicator
41
Foley Limit status-OFF
74
WiFi-signal strength indicator
42
Bed Location control-bed located
43
WiFi-bed equipped with 42 WiFi, but no WiFi Signal found indicator
Bed Location indicator-con- 43 trol is active to show the bed’s location
+/- Control (Add/Remove Items)
MCM-ON indicator for beds equipped with the pro+ mattress (integrated)
63
Centrella Smart+ Bed Instructions for Use (193587 REV 15)
108
7